Download Print this page

hager Comfort EE87 Series Quick Start Manual page 2

Motion detectors

Advertisement

Available languages

Available languages

Product presentation
and operating principles
This detector allows automatic control of a
light source for a defined length of time when a
movement is detected in the surveillance zone.
The LED A indicates a movement. It is inhibited by
default except in Test mode.
Settings and Test
The detectors have 2 modes of operation:
Fixed time and Control by timer.
Power supply
The detector switches the light on for 40 s.
After 40 s, it activates the Normal mode.
Testing and validating
the detection zone
Put the potentiometer 2 on Test mode and if
necessary, use the shutters to define the detection
zone.
The Test mode is available for 3 min. Every
movement detected switches on the light for 1s.
After 3 min without detection of movement, the
product returns to normal operation.
Limiting the detection zone
You can limit the detection zone by using the
shutters provided or by tilting the head.
"Normal" operation (on/off)
The lighting is activated whenever the level of
luminosity defined by the potentiometer 2 is
judged to be insufficient and a movement is
detected.
After detection, the light stays on for the length
of time predefined by the potentiometer 1.
The fixed timing is reset after each detection.
Please note: when the potentiometer is on "auto
test", the settings are predefined.
Control by timer
An impulse is generated every 10 s whenever the
level of luminosity is judged to be insufficient and
a movement is detected when the potentiometer
1 is on V.
This pulse mode is not suitable for connections to
power devices (except at low power loads).
Using the remote control (option,
ref. EE806)
The detector receives instructions from the remote
control when the Lux potentiometer is on the "auto
test" position.
If the potentiometer is put on another value, the
local setting resumes.
The LED B of the detector lights up to confirm the
signal with the remote control.
It flashes quickly for 2 s when an instruction is
received and 5 s for a reset.
When an instruction is not authorised, the LED
lights up for 1 s.
The available settings are:
- fixed time
- level of luminosity
- sensitivity
- on / off
- holidays (simulation of presence)
- activation of the detection A.
2
Montage
Surface-mounting or ceiling-mounted :
- fix the wall plate using the screws provided
- connect the wall plate terminal block (see cabling plans in annex)
- fully insert the detector on the wall plate
- tighten the screws to ensure the product is sealed.
For corner fixing, the wall plate is to be fixed between the accessory and the detector.
Cable entry (breakable partitions) are possible:
- by the back (box mounting) or by the bottom.
Wiring and connections (provide installation with fixed wiring)
60 mm
N
L
S'
Operating precautions
In order to obtain optimal detection conditions, it is recommended that the following advice:
- the detection is sensitive to solar radiation and bad weather. Detection performance is optimal up to
35 °C and above 40 °C.
- It is preferable to maintain à distance of 1 m. between a light source and the detector.
When mounting on a box, make sure that you do not distort the wall plate through excessive tightening
of the screws.
Action
Settings
Use Auto settings
Auto Settings
(factory) or set by
Put the Lux potentiometer on
the remote control
"auto test".
to switch the light
The settings are predefined:
automatically for a
Lux = o
given time.
(operating at night only)
time = 3 min,
sensitivity = max.
Remote control settings
(Manual Settings inhibited).
Automatically switch
Installer settings
on the light for a
defined time.
Control a timer, a bell
Impuls V
etc.
Auto settings are usable with
time = 1s. (cannot be changed)
Test and validate the
Test mode
detection zone.
Move the potentiometer 2 to
"auto test". On this position, the
remote control can be used.
Adjust the sensitivity.
Allows setting the range
to avoid disturbance.
Ateha raceways
N
L
S'
ref. ATA 12200
or ATA 63000
Potentiometer
6E7582.C