12-volt emergency battery sump pump system

Advertisement

STEP 12
Fix the control box to the battery box.
STEP 13
Plug the float switch, pump and charger to the appropriate connector as
per Figure. 5. Test pump operation by filling the sump with water while
the main AC pump is unplugged. If the pump operates properly, plug the
charger into the GFCI protected outlet to keep the battery charged.
STEP 14
Protect electrical cord from sharp objects, hot surfaces, oil and
chemicals. Avoid kinking the cord and replace damaged components
immediately.
The control box contains a multi-colored indicator lights.
1- The green charged light indicates a full charge.
2- The red battery low light indicates a low voltage.
3- The yellow charging light indicates a charge function in process.
4- The red reversed light indicates a reverse connection on the battery cables.
5- The alarm selector can be put in on or off position as per your choice. If the alarm turns on, the
red alarm light will turn on.
6- To test the pump operation, push the pump test button.
7- To stop the alarm, if in on position, push the reset button.
Note that if activated, the alarm will turn on as soon as the pump turns on. This will warn you
that the pump turned on due to a power failure or a primary pump failure.
SPARE PARTS LIST
NO
Material
1 Upper box cover
2 Lower box base
3 Alternative handles (2)
4 Screws (4)
5 PVC ties (4)
6 Black belt
7 Float
8 Pump
9 Impeller & lock washer
10 Pump O -Ring
11 Volute
12 Suction screen
13 Reducer 1" to 1 1/4"
14 90° Elbow
15 1 1/4" check valve
16 AC Adaptor
17 Control box
18 Big head screws (4)
19 Battery cable clamp
Figure. 5