Download Print this page
Randell 64335A Specifications

Randell 64335A Specifications

Ranspec remote worktop freezer

Advertisement

Quick Links

RanSpec Remote Worktop Freezer
model
64335A
Description:
Remote freezer base with 16 gauge reinforced stainless steel
top, and integral backsplash with 45˚ return. Stainless steel
doors on concealed hinges. CFC free, R-404a refrigeration
system. Condensing unit and controls not provided. Evaporator
blower coil with expansion valve supplied and installed. Unit
with automatic defrost system, and heated door frames. 6" high
adjustable and movable legs.
Specifications:
CABINET EXTERIOR: Top to be one piece of die-formed 16 gauge
stainless steel with 2 1/2" nosing. Backsplash to be coved
cornered, with 45˚ return at top and overall height of 6 3/4".
Ends at top fitted with recessed heavy duty steel bars for field
bolting units together, producing a hairline seam. Exterior body
to be corrosion resistant steel. Door opening frame to be ABS
and contain magnetic strip for positive sealing of gaskets and
heater elements to prevent gasket freezing. Back-up element
installed. Work surface to be at 36" work height. Legs to be 6"
high stainless steel with adjustable bullet foot. Legs mounted to
full length channel frame assembly which is integrally welded
to bottom of body assembly. Legs can be moved left to right to
avoid floor obstacles during installation.
CABINET INTERIOR: Base interior to be ABS thermoplastic at
ends only. Stainless steel interior liner to be coved cornered to
form bottom, back and top. One baked enamel finished shelf
provided behind each door. Unit insulation to be CFC free foamed
in place urethane.
DOORS: Door fronts to be 22 gauge stainless steel with 16 gauge
stainless steel handles, magnetic gaskets, ABS door liner and
foamed in place insulation. Hinges are concealed, all stainless
steel with bronze pivot pin in nylon bushing.
REFRIGERATION: Refrigerant to be specified by customer
(Specification based on R-404a refrigerant). Interior fitted with
Randell evaporator blower coil for cooling base. Expansion valve
and refrigeration lines provided and installed for connection at
unit rear. Blower coil fitted with expansion valve for fast recovery
and automatic defrost heater system with digital control and
safety switches. Condensing unit not provided. Unit totally
prewired to junction box for 115V operation.
1055 Mendell Davis Drive, Jackson, MS 39272
888-994-7636, unifiedbrands.net
Information contained in this document is known to be current and accurate at the time
of printing/creation. Unified Brands recommends referencing our product line websites,
unifiedbrands.net, for the most updated product information and specifications.
64338A
64341A
models 64000A
64352A
64358A
Shown with optional finished end.
Standard Features:
• Available under one piece top with other modular
equipment up to 16' in length
• 6" high legs—adjustable and movable
• Foamed in place "CFC free" urethane insulation
• Refrigeration system utilizes "CFC free" R- 404a
refrigerant, expansion valve for fast recovery, and
digital control for field adjustability and solenoid value
• Automatic coil defrost system
• 45˚ integral stainless backsplash is standard. 90˚
stainless backsplash is optional.
• Front breathing louver design allows sealing to wall &
curb mounting without special requirements
• Precise temperature settings, LED temperature readout
• Filter dryer installed on liquid line
Options & Accessories:
Stainless Steel Ends
Stainless Steel Back
Casters in lieu of legs
Flat Top with no backsplash
64364A
64382A
Randell RanSpec, Page 26
Revised 07/07

Advertisement

loading

Summary of Contents for Randell 64335A

  • Page 1 REFRIGERATION: Refrigerant to be specified by customer (Specification based on R-404a refrigerant). Interior fitted with Randell evaporator blower coil for cooling base. Expansion valve and refrigeration lines provided and installed for connection at unit rear. Blower coil fitted with expansion valve for fast recovery and automatic defrost heater system with digital control and safety switches.
  • Page 2 * BTU loads shown are based on 100°F ambient with 30% added for usage and product loading. Final system selection should consider usage requirements and combined loads. Recommended HP reflects Randell HP applied to self-contained (single) unit of equal storage capacity. Increasing HP may be appropriate in some remote applications.

This manual is also suitable for:

64338a64341a64352a64358a64364a64382a