Assembly and Maintenance Advice 1. For safety purposes, we strongly recommend that this product is assembled by at least two people. 2. Some components have sharp metal edges. Please be careful when handling metal components. Please wear gloves, shoes and safety goggles during assembly. 3.
Page 4
3. Base anchor brackets are included as standard with expanding bolts to ensure a secure fixing into concrete or paving. Alternatively, you can use the brackets to fix into a timber base with wood screws (not provided). Steel bar/Lawn land Expansion bolt in concrete 4.
Page 5
7. Remove approximately 2 inches of film from all sheet edges before installing and remove all film immediately after the construction is completed. Please ensure that the side with the white film faces outwards. 8. This product can be extended freely. We have basic 3 sections and EXT. 2 sections. So, it can be extended to 5 sections or 7 or longer.
GM34303(ALU.Box No.1) PART PART PART PART NEW OLD L01A L16A L06A L01B L16B L07A L08B L01C L01D L18A L09A L03C L18D L02A L03D L21C L02B J10R/L J02R/L L03E L21D L04A J03R/L J12R/L L15A L03F L11C L04A L21A L05C L21B L05A...
Page 7
GM34303(PC/GLASS No.1) PART Rubber for walls & roof (Provided for glass only) PC/GLASS PART No.1 113M Rubber for walls only (Provided for glass only)
Page 8
EXT. 2 Sections(AU.Box No.2) PART PART PART NEW L15A L21A L08A L21B L19A L19B L02A L02B L04A L11C L12G M8X60 L05C M6X20 L05D M6X10 L22A Ø4X16 L22C L12A Ø4X16D L12B Ø4X8 L03A M5X25 L03B EXT. 2 Sections(PC/GLASS No.2) PART Rubber for walls & roof (Provided for glass only) PC/Glass PART...
PART PART PART L15A L19A Ø4X16 L19B Ø4X16D Ø4X8 L21A L21B Roof Vent Assembly Overview L15A L19A L19A L21B L21A L21A L19B L21B...
Page 15
L19A L19A L19B After connector A27 has been fitted, use the hole in the profile to tighten the connector in place. L19A L19B L19A Push down the button on connector A27 before inserting it into the end of the frame profile.
Page 16
L21B L21A L21A L21B L21A/L21B First the glazing panel Y10 should be loosely retained by the bar capping profiles L21A and L21B. Next tap the bar capping gently into position with a rubber mallet, then fix the bar capping securely with Z22 screws.
Page 17
Install the Z02 screws to prevent the L15A from sliding off the vent. L15A L15A Fix the A01 vent handles using Z03 screws. If required, automatic vent openers can be installed once the greenhouse is complete. Fill silicone sealant all around Y10 and the gaps between the aluminium frames to avoid any water leaking...
PART PART PART L16A L16B J12R/L M6X10 L18A L18D M8X30 Door Assembly L21C L21D Ø4X16 Overview Ø4X16D Ø4X50 Frames W03R W03L L18D L16A Aluminium Capping L16B L18A L21C L16A L21D L16A L18A L16B L21C L21D L16A L18D L21C...
Page 19
Slide L16A into L17A and L18D and slide L16B into L18A and L18B, then assemble the door frames using connector A28, as shown in the W22x2pcs sketches below. L18D L16A/L16B L18A/L18C L18A/L18C S02x2pcs L16A/L16B L16A L17A L16A L16B L16B L18D L18A/L18B L17A L16A...
Page 20
First the glazing panels should be loosely retained by the bar capping profiles L21C and L21D. Next tap the bar capping gently into position with a rubber mallet, then fix the bar capping securely with Z22 screws. L21C L21D L21C/21D L21D L21C/21D L21C...
Page 21
Slide 2xS02 into L18D, positioned 100mm away from each edge. Secure S12 using M06 bolts, then rotate the wheels to ensure free movement. * This is the method of adjusting the door height. L18D After Assembly...
Expansion bolt in concrete It is essential the dimensions a + b are the same to ensure the base is square. Steel pegs in soil Support at the corners only is inadequate.
Page 23
GM34303 Rear Front 3 Section Front GM34303 GM34305 GM34307 GM34309 GM34311 etc. 1910.7 1910.7 1910.7 1910.7 1910.7 (mm) 1949.9 3184.9 4419.9 5654.9 6889.9 (mm) 2730 3714.1 4815.2 5969 7149.9 (mm) a1=b1 2642 3598 4670 5794.1 6944.9 (mm) * W= Outer Width of Base Profiles...
Page 24
GM34305 Rear Front 2 Section GM34303 EXT. 2 Setions GM34305 * The basic model,GM34303,can be easily extended by adding ' 2 Section Assembly' each time for a longer size.
Attention: the following steps are assembly example for GM34305 (GM34303 + one EXT.2 Sections). If you only buy the basic GM34303, there will be only L08B, without L08A. If your greenhouse consists of more than one extension module, then you will have more D24 joining plates to join the L08B and A's.
Page 26
PART Install the corner posts as shown and secure with the nuts & bolts provided. L01A L01A/L01B L01B L03C L03D L05A L01B M6X10 L01A L01A L01B L05A L05A L03D L03C Slidein S14x2pcs L08C L08C Slidein S14x2pcs L05A L05A L03C L03D...
Page 27
PART L01C L01D L01D L01C M6X10 Install L01C and L01D using connector A26 and part D17, then tighten them with the nuts and bolts provided. View from inside L01C/L01D L01D L01C L03C/L03D Connect L01B to L01D and L01A to L01C using connector A26 and part D17, then tighten them with the nuts and bolts provided.
Page 28
PART L04A L05B Install L13 horizontal braces in the rear wall. Then install L04A & L05B with the nuts & bolts provided. M6X10 Remember to bolt the L05B brace in place when installing L04A. L04A L04A L04A L05B L05B L03C/L03D L01A/L01B L04A L05B...
Page 29
PART L03E L03F Install the door framing and bracing. L04A L05A M6X10 L04A L04A L05A L05A L03E L03F L03E/L03F L05A L03E/L03F L01A/L01B L04A L05A L04A L03E/L03F S14x3pcs...
Page 30
PART * During construction please ensure you temporarily support L01C the front and rear wall framing until the structure is complete. L01D L01C M6X10 L01D Install L01C and L01D using connector A26 and part D17, then tighten them with the nuts and bolts provided. View from inside L01C/L01D L01D...
Page 31
Attention: If you only buy the basic GM34303, there will be only L06A, without L06. If your greenhouse consists of more than one extension module, then you will have more L27 & L06 to extend. 250mm Insert half part of L27 into L06, leaving 250mm length of L27. Then secure L27 and L06 with Z05.
Page 32
Please follow these steps if your order includes decorative cresting. PART L26A M4.2X16 Cut off 56mm from two profiles, L26, Drill one hole on both sides of L26, Dia.3.2mm, 150mm near to D26, and then install all L26 from centre of each L26, through L06A & L06, and then onto L06A &...
Page 33
Attention: If you only buy the basic GM34303, there will be only L07A, without L07. If your greenhouse consists of more than one extension module, then you will have more L07 to extend. L07A Assemble L07 & L07A through D25 & D27, and tighten them with bolts and nuts (see Fig.
Page 34
PART * When installing the L22C before tightening the nuts and bolts, push up from under the ridge near the join to ensure the entire ridge is straight. L02A L03A L03B L03B L22C L03B M6X10 L22C L22C L22C L03A L03A * Also ensure the eave profiles are running true and straight from end to end before tightening the L22Cs at the sides.
Page 35
Install horizontal & diagonal braces as shown to both sides of the greenhouse, PART ensuring that you loosely insert 1 extra bolt in the channel, L02B which is needed later to fix the bracing L22A & L22B L05C L22A L22B M6X10 L05C L05C...
Page 36
PART Install the L04A vent frame profile and the A03 handle frame profile. Handle frame A03 is not required if auto openers are installed. L04A Install L04A and L05D at the same time. L05D When installing L05D ensure that you leave one bolt in the bolt channel for L22. Install the L22 ridge and eaves struts.
PART L11A L11B L11C L11B L12C L12D L12G L12G L12G L12G L11A L12D L11A L12C L11C L11C L11C First the glazing panels should be loosely retained by the bar capping profiles as shown in the detail drawings. Next tap the bar capping gently into position with a rubber mallet.
Page 38
PART L11A L11B L11D L11B L11E L12C L11E L12D L12G L12G L12G L11A L12C L12D L11A L11D L11D First the glazing panels should be loosely retained by the bar capping profiles as shown in the detail drawings. Next tap the bar capping gently into position with a rubber mallet.
Page 39
PART L11A L11C L12A L11A L12A L11A L12A L12A L12A L11C L11C L11C L11C L11C Slide all Y6 glazing panels into place. The top of the panels should be pushed up behind the gutter profile, then pushed in against the base profile as shown in the detail drawings. The panels should be loosely retained by the glazing bar capping L11A, L11C and L12A then tap the bar capping gently into the channels of each frame profile with a rubber mallet.
Page 41
PART L12B L11B L12B L12B L12G L12B L09A L11B L12G L11B L12B L12G L12B L11B L12G L12G L12B L12B L12B L11B Tap all of the bar capping into the channels of each frame profile with a rubber mallet as shown in the detail drawings.
Page 42
Fix every bar capping profile securely in position using Z22 screws as shown in the detail drawings. * Be careful not to over tighten but ensure the screws are securely fixed. Ensure the bar capping profiles are pushed firmly against the panel before installing the screws.
Page 43
Window x4pcs PART WINDOWS Ø4X16D PART AUTO OPENER M6X20 L19B L04A L06/L06A L15A *Ensure the manual vent is closed as shown. L15A L04A L19B L04A Z02x2 S12/M03 Slide L15A along the groove in the L06 ridge and fix it in the correct position using Z02 screws.
Page 44
Door Rotate H18, the roller wheels, to adjust the height of the door so it does not bind or rub on the bottom track. Door Door...
Page 45
PART J10R/L J12R/L Ø4X16D Ø4X16 J02R/L Downpipe Assembly If you wish to eliminate leaks Drill a hole in L01A and L01B, use glue when fixing the downpipe approximately 3mm diameter and 700mm bends (not provided). up from the bottom. Fix the J92 downpipe bracket with Z22 screws and then clip the L30 downpipe into the J92 bracket.