Please read fully to ensure your Formula Pro' Advanced works properly every time.
Disassemble and wash all parts (except the base) and dry thoroughly.
Disassembly tip:
To remove the Stirring Wheel, grasp it as shown above & pull up while holding the powder container down.
Never clean the Powder Container in a dishwasher, sterilizer or microwave!
Set-up and cleaning videos available at babybrezza.com/video.
Now you're ready to add powder and make your first bottle.
LCD Display: Shows selected functions & warnings
Powder setting button: Press to select setting number for your formula brand and type.
Water only button: Press to dispense ml displayed on LCD (selected by the "ml" button).
Temp button: Press to select your warming temperature.
ml button: Press to select ml of water dispensed.
Start button: Press to start dispensing formula.
Power button: Press to turn unit on or off.
![]() | = Room temperature | ![]() | = Body temperature | ![]() | = Slightly warmer than body temperature |
![]() | Powder Setting Indicator - Use the "powder setting" button to chose your powder setting 1-10. |
![]() | ml Indicator - Use the "ml" button to choose how many ml of water to mix with powder. 60, 30, 90, 120, 150, 180, 210, 240, 270, 300 ml of water are available. There is no option to make a 30ml bottle. |
The Formula Pro® Advanced will not run if any of these symbols are illuminated on the LCD display.
![]() | Powder Lid Open - The powder container lid is not closed completely or is not on the powder container correctly. Close the powder container lid completely and correctly when this symbol is illuminated. |
![]() | Low Water - Refill water tank when this symbol is illuminated. |
![]() | ~=Clean Funnel - This symbol will illuminate after every 4 bottles are made. When this symbol is illuminated, remove funnel assembly, wash, and dry completely, then place it back into the base. |
![]() | Funnel Out - Funnel is removed or not inserted completely. Make sure the funnel is pushed all the way in when this symbol is illuminated. |
Make sure your Formula Pro® Advanced is plugged in.
![]() | = Slightly warmer than body temperature |
![]() | = Body temperature |
![]() | = Room temperature |
It is EXTREMELY IMPORTANT to clean the funnel after every 4 bottles made.
This will keep your Formula Pro® Advanced dispensing accurately. Always make sure Funnel & Funnel cover are COMPLETELY DRY before re-assembling.
PLEASE NOTE: You don't need to remove the powder container or the powder container parts for daily cleaning.
Once a month, give your Formula Pro® Advanced a thorough cleaning.
Please watch set-up and cleaning videos at babybrezza.com/video.
You can leave the formula powder in the powder tank during the descaling process.
To prevent mineral scale on the water heater inside your Formula Pro® Advanced, follow these easy steps:
It is EXTREMELY IMPORTANT to clean the machine and remove all formula powder residue before storage.
If you're going to store your Formula Pro® Advanced for later use, or will not use it for a while, please follow the instructions below:
In the unlikely event of electrical component error or interruption during operation, the following codes will be displayed on the LCD screen. Pressing and holding the "stop" button will clear the code and operation should return to normal. If the code returns or is unable to be cleared, please contact Baby Brezza Customer Service.
![]() | Indicates an operation error of the motor that turns the powder container parts. Contact local Customer Service. |
![]() | Indicates an operation error of the motor sensor that detects the rotation of the measuring wheel. Contact local Customer Service. |
![]() | Indicates an operation error of the water flow meter that measures the water volume output. Contact local Customer Service. |
![]() | Indicates an operation error of the temperature sensor that measures water temperature. Contact local Customer Service. |
![]() | Indicates an operation error of the water level switch that measures the water remaining. Contact local Customer Service. |
![]() | Indicates that hot water has been poured into the water tank and entered the machine. Empty the water tank, refill it with room temperature water, return it to the base. Press & hold the "stop" button to clear the code, then press & hold the "water only" button to clear the hot water from the machine. |
![]() | Indicates that the powder container lid has been opened during operation. Make sure the powder container lid is completely closed, press & hold the "stop" button to clear the code. The machine will return to normal. |
![]() | Indicates that the funnel has been removed during operation. Make sure the funnel & funnel cover are Installed correctly, press & hold the "stop" button to clear the code. The machine will return to normal. |
Condition | Possible Cause | Possible Remedy |
Machine will not start | Unit is unplugged. | Make sure the plug is securely inserted into the power outlet. |
Funnel is removed or not fully inserted. | Insert funnel or push front of funnel until flush with machine. | |
Water level is below "MIN" line. | Add more water to water tank. | |
Powder container is removed or not fully seated. | Make sure powder container is placed on base properly. | |
Powder container lid is not completely closed. | Turn Powder container lid clockwise to close completely. | |
Powder container lid is on backwards. | Make sure tab on edge of Powder Container Lid is facing the back of the machine and engaged with safety switch. | |
Water in Water Tank is too cold. (Temp Symbol on LCD Flashing) | Wait for water to warm up. | |
Water in Water Tank is too hot. (Temp Symbol on LCD panel is flashing) | Wait for water to cool down. | |
Temperature of dispensed formula is too cold | Water has not yet been heated to correct temperature. | Wait for heater to warm water. Make sure selected temperature symbol stays on solid instead of flashing. |
Funnel will not fit all the way in Funnel Compartment. | Funnel cover is not straight on funnel and/or not pushed down completely. | Align tab on front of Funnel Cover with notch in Funnel and push down Funnel Cover completely. |
Clean Funnel symbol is on, Formula Pro beeps when start button is pressed. | Funnel and hole on underside of Powder Container require cleaning. | Follow Steps to clean and dry Funnel and hole on underside of Powder Container. |
Too much powder dispensed | Locking cover is not installed correctly. | Check locking cover and make sure the front edge is locked under the tab in the powder container. |
Incorrect powder setting selected. | Make sure to select the correct setting number for your powder type. For details, go to: babybrezza.com/settings | |
Not enough powder dispensed | Powder level in powder container is too low. | Refill Powder Container with more powder. |
Machine has not been cleaned well. | Disassemble, clean by hand-washing, completely dry all parts and reassemble. | |
Silicone scraper is not installed correctly. | Make sure silicone scraper is installed correctly. | |
Incorrect powder setting selected. | Go to: babybrezza.com/fpa to confirm setting for your powder brand and type, then choose correct setting using the "powder setting" button on the control panel. | |
Not dispensing water | Water Tank not fully seated. | Push Water Tank down all the way on Base. |
Powder build-up on funnel cover & underside of powder container. | Frequent use without cleaning underside of powder container. | Clean funnel, funnel cover and underside of powder container every 4 bottles. |
If you can not remedy problems by using the troubleshooting chart above, visit babybrezza.com/pages/international to locate your local customer service representative.
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Baby Brezza Formula Pro Advanced - Dispenser Machine Manual
Advertisement
Need help?
Do you have a question about the Formula Pro Advanced and is the answer not in the manual?
Questions and answers