LK 421 Manifold Shunt
 
TECHNICAL DATA
Max. operating pressure
Max. pressure differential
in operation
Operational temperature
secondary
Operational temperature
primary
Ambient temperature
Circulation pump
Voltage
Output
Current
Cable protection class
Relative humidity
Max. valve capacity control
valve V1 with hand actuator fitted.
Max. valve capacity control
valve V1 with electric valve actuator.
Control valve V2
Material
Media
Approved pump
1.
Supply flow from primary circuit. Female threads ¾".
2.
Locking control valve. Used to close the primary side, see
heading, Shutting off primary side.
3.
Return flow connection to primary circuit. Female threads ¾".
4.
Isolation/flow control valve primary return (V2). Valve for
adjustment and control of the primary flow. Also used as iso-
lation valve. 8 mm hexagonal socket.
5.
Return flow from the underfloor heating circuit. Male threads
1".
6.
Built-in thermometers located in the underfloor heating return
flow.
7.
Bracket.
8.
VF Valve (VF). Should only be used in installations with low
available drive pressure from the primary side of the circula-
tion pump. 8 mm hexagonal socket.
9.
Built-in check valve.
10. Pump connector.
1.0 MPa
0.1 Mpa
+12 - +65 ºC
Max. +80 ºC
Max. +70 ºC
Grundfos UPM3 Auto 15-70,
with cast iron pump housing
1 phase 230V AC, -15 %/
+10 %, 50 Hz, PE
Max. 52 W
Max. 0.52 A
IP44
Max. 95%
Kv 2.2
Kv 3.6
Kvs 4,1
Nickel-plated brass MS58,
stainless acid-proof steel
Water, water/glycol 50/50%,
water/ethanol 70/30%
CE, EC Low Voltage Directive
(2006/95/ EC) incl. additions
www.lkarmatur.com
11. Supply flow to underfloor heating circuit. Male threads 1".
12. Circulation pump Grundfos UPM3 Auto 15-70 with automatic
speed control.
13. Temperature limiter (TEMP). Factory-set to 50 °C.
Adjustable between 22 - 65 °C, see table.
14. Built-in thermometers located in the underfloor heating supply flow
15. Two-way control valve (V1). The control valve is fitted with a
hand actuator to manually adjust the supply flow temperature.
The valve is also used to close the primary side, see heading, Shutting
off primary side.
11
10
9
8
7
6
5
4
3
2
12
13
14
15
1
1

Advertisement

Table of Contents
loading

Summary of Contents for LK Armatur LK 421

  • Page 1 LK 421 Manifold Shunt   11. Supply flow to underfloor heating circuit. Male threads 1”. TECHNICAL DATA 12. Circulation pump Grundfos UPM3 Auto 15-70 with automatic Max. operating pressure 1.0 MPa speed control. Max. pressure differential in operation 0.1 Mpa 13.
  • Page 2 DIMENSIONS DRAWING LEFT DESIGN LK 421 Manifold Shunt 2.0 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds. The shunt unit is fitted as standard with a hand actuator on the control valve and with an ad- justable maximum limit function of supply temperature.
  • Page 3 REQUIREMENTS The circulation pump has automatic speed control, which reduces LK 421 Manifold Shunt 2.0 should be used in systems with a primary power consumption and gives a quieter operation as the pump supply temperature that is weather dependent. Check the settings of adjusts the flow according to the requirements of the system.
  • Page 4 ENG | Instruction Manual ELECTRICAL CONNECTION SHUTTING OFF PRIMARY SIDE The shunt unit can be used to shut off the primary side, e.g. during The electrical connection is easily set up with the accompanying plug, service work on the shunt unit or underfloor heating manifold. with built-in strain relief.
  • Page 5: Troubleshooting

    ENG | Instruction Manual TROUBLESHOOTING he floor heating circuit is not heating up or not heating sufficiently. • Check that the control valves (V1+V2) are open. See heading, Shutting off primary side. • Check settings for the control valve (V1). •...
  • Page 6: Technische Daten

    LK 421 Manifold Shunt   8. VF-Ventil (VF). Wird nur in Anlagen mit geringem An- TECHNISCHE DATEN triebsdruck auf der Primärseite der Umwälzpumpe Max. Betriebsdruck 1,0 MPa verwendet. Innensechskant 8 mm. Maximaler Differenzdruck in Betrieb. 0,1 MPa 9. Eingebautes Rückschlagventil.
  • Page 7 DE | Bedienungsanleitung AUSFÜHRUNG MASSZEICHNUNG LINKS Die LK 421 Verteilerregelstation 2.0 ist eine Verteilereinheit mit 2-Wege-Steuerventil für Systeme mit Hauptpunkte. Die Verteiler- einheit kann direkt an LK-Heizkreisverteiler in Rechts- oder Link- sausführung angebracht werden. Die Verteilereinheit besitzt ein Steuerventil mit Handbedienelement und eine Begrenzungsfunk- tion für die maximale Vorlauftemperatur.
  • Page 8 VORAUSSETZUNGEN UMWÄLZPUMPE Die Umwälzpumpe besitzt eine automatische Drehzahlregelung, die den Die LK 421 Verteilerregelstation 2.0 muss in ein System mit Energieverbrauch und das Betriebsgeräusch der Pumpen verringert, außentemperaturkompensierter primärer Vorlauftemperatur da die Pumpe den Durchfluss je nach den Anforderungen der Anlage eingebaut werden.
  • Page 9: Betrieb

    DE | Bedienungsanleitung ELEKTRISCHER ANSCHLUSS ABSPERREN DER PRIMÄRSEITE Die Verteilereinheit kann bei Bedarf gegenüber der Primärseite ab- Der elektrische Anschluss erfolgt einfach über den mitgelieferten gesperrt werden, z. B. bei Wartungsarbeiten an der Verteilereinheit Stecker mit integrierter Zugentlastung. Der Stecker ersetzt einen oder am Bodenheizungsverteiler.
  • Page 10: Fehlersuche

    FLUSSSCHEMA 15. Steuerventil (V1). 4. Regelventil/Sperren des Primärrücklaufs (V2). 13. Temperaturbegrenzer (TEMP). 12. Umwälzpumpe. 9. Eingebautes Rückschlagventil. 8. VF-Ventil (VF). E. Sekundärseite, Fußbodenheizungssystem. F. Primärseite, System mit Hauptpumpe. TEMP LK ARMATUR AB www.lkarmatur.se www.lkarmatur.com LK ARMATUR DEUTSCHLAND GMBH www.lkarmatur.de www.lkarmatur.de...

Table of Contents