Page 1
5:1 Mobile Oil Dispensing Kit Instruction Manual M3OKT516-KIT M3OKT555-KIT WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious personal injury. Save these instructions in a safe place and on hand so that they can be read when required.
GENERAL SAFETY REGULATIONS WARNING: The warnings, cautions, and instructions discussed in this instruction manual cannot cover all possible conditions or situations that could occur. It must be understood by the operator that common sense and caution are factors that cannot be built into this product, but must be supplied by the operator.
3 years from date of purchase, but not including wearing parts. 2. Macnaught’s liability is limited to replacement or repair of defective material within the warranty period, when returned freight prepaid to the distributor or their designated service depot.
INSTALLATION STEPS Note: Before connecting and assembling each component, please assemble each component according to the component instructions). Step 1 Step 2 1. Assemble the trolley (part No. 1) 1. Install the pump (part No. 2) into the according to its instruction manual. corresponding fixing hole of the trolley.
Page 5
EXPLODED VIEW AND DETAILS M3OKT555-KIT M3OKT516-KIT Part No. Description Trolley Oil Pump Delivery Hose Assembly Oil Control Valve * Wearing parts.
Page 6
TECHNICAL DETAILS - TROLLEY ASSEMBLY Item No. Drums Capacity Drums Diameter M3TR5 5-16Gallon 385mm DRUM TROLLEY EXPLODED AND PARTS LIST - M3OKT516-KIT Part No. Description Q’ty Part No. Description Q’ty Screw Blocker Trolley Top M6 Bolt Washer Handle Handle Cover...
Page 7
TECHNICAL DETAILS - TROLLEY ASSEMBLY Item No. Drums Capacity Drums Diameter M3TR205 600mm 48-58Gallon DRUM TROLLEY EXPLODED AND PARTS LIST - M3OKT555-KIT Part No. Description Q’ty Part No. Description Q’ty Accessories A swivelling wheel Drum holder support Hexagon bolt Handle Washer Pump support Wheel...
TROUBLE SHOOTING Problem Possible Causes Solutions The Pump can’t work 1. Insufficient air 1. Increase air pressure 2. Air obstruction 2. Clear air passage 3. Change voltage 1. The intake valve is closed 1. Open the intake valve 2. The intake valve is blocked 2.
HOW TO USE Directly Fitted Pump into the Drum 1. Insert the suction tube of pump into the drum and secure with ring nut, suitable for commercial drums with 57mm diameter hole and threading 2” BSP 2. Fit a oil delivery tube for oil outlet of the air operated pump using only high quality tubes (normally 1/2”, according to DIN-SAE norms(), by means of 1/2”...
Page 11
Extension Transfer Part List Part No. Description Oil pump Bung adapter Top connection Extension 500mm tube Extension sleeve Extension 200mm tube Foot connection Foot valve Filter Proceed as follows 1. Depending on the length of the suction tube the desired extension length. Can be realized by using the modular extension elements (See the examples given above) 2.
Page 13
Part No. Description Part No. Description Q’ty Q’ty Air motor cover Circlip - Type A Spring Oil inlet O-ring Washer Guide belt Tube Piston sealing Cross screw Base Retainer plate Piston O-ring Base Circlip - Type A Washer Shaft Spring Connector Spring Elastic pin...
TECHNICAL DETAILS - OIL CONTROL VALVE Item No. 18123522 Inlet 1/2" NPT Female Configure Flexible nozzle, auto tip Flow Rate 0.3-9GPM 7-1500psi Operating Pressure Range 140°F Max Operation Temperature ±0.5% Accuracy ER14250 3.6V Battery SAFETY PRECAUTIONS EQUIPMENT MISUSE HAZARD 1. This equipment is for professional use only. 2.
Page 15
Installation Procedure If this is a new installation, or if the oil in the lines is contaminated, flush the lines before you install the dispense valve. 1: Air inlet 2: Air shut-off valve 3: Oil pump 4: Fluid shut-off valve 5: Meter 6: Control valve 7: Hose reel...
4. Apply thread sealant to the male threads of the hose fitting, thread the hose fitting into the swivel, and tighten firmly. 5. Thread the new nozzle or nozzle adapter onto the extension, and tighten firmly. 6. Open all dispense position shut-off valves, and start the pump to pressurize the system. See the Operation section for proper operation.
Page 17
Show Current Correction Factor Press Menu key and Reset key together. The display will show the correction factor, which can be reset. Reset The Resettlement Total Press Menu key for 10 seconds, the accumulated total will be reset to be “0”. To Change the Measurement Units (L / GAL/ PT / QT meter only) 1.
TROUBLE SHOOTING GUIDE Relieve the pressure before you check or repair the dispensing valve. Be sure all other valves and controls and the pump are operating properly. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the pressure relief procedure.
Page 19
EXPLODED AND PARTS LIST 1-13 1-12 3-19 1-11 1-10 3-21 3-20 3-18 3-14 3-17 3-15 Wearing parts: 3-10 Part No. Description Q’ty 3-16 3-9* O-ring 3-13* Battery 3-13 3-19* waterproof protector 3-12 3-20* Seal washer 3-11 Part No. Q’ty Q’ty Description Part No.