Fujitsu ASTG34KMTB Operating Manual

Fujitsu ASTG34KMTB Operating Manual

Wall mounted type
Hide thumbs Also See for ASTG34KMTB:

Advertisement

Quick Links

AIR CONDITIONER
Wall Mounted Type
ASTG30KMTB
ASTG34KMTB
Before using this product, read these instructions thoroughly. Also, keep this manual for future reference,
together with the installation manuals for the indoor and outdoor units.

Safety Precautions

To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classified as follows:
This mark warns of death or serious injury.
This mark denotes an action that is PROHIBITED.
• Explanation of symbols displayed on the indoor unit or outdoor unit.
This symbol shows that this appliance uses a flammable refrigerant. If the refrigerant is leaked and exposure to an external
WARNING
ignition source, there is a risk of fire.
CAUTION
This symbol shows that the Operation Manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION
This symbol shows that information is available such as the Operating Manual or Installation Manual.
• The appliance, outlet and inlet shall be installed, operated
and stored in a room with a floor area larger than X m
M (kg)
M ≤ 1.65
30 type
X (m
)
2
M (kg)
M ≤ 2.00
34 type
X (m
)
2
M (kg): Amount of refrigerant charge
X (m
): Minimum room area
2
• The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or fire.
• In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
• Take care not to damage the power supply cable.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons
in order to avoid a hazard.
9387081145_OM.indd 1
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
WARNING
1.65 < M ≤ 2.05 2.05 < M ≤ 2.45 2.45 < M ≤ 2.85
2.60
4.01
5.72
2.00 < M ≤ 2.45 2.45 < M ≤ 2.90
3.81
5.72
8.02
( IEC 60335-2-40 )
PART No. 9387081145
OPERATING MANUAL
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 3
Timer Operation.................................................................... 6
Human Sensor (Energy Saving) ........................................... 8
General Informations on Operation ...................................... 9
Cleaning and Care.............................................................. 10
Troubleshooting .................................................................. 12
This mark warns of injury or damage to property.
This mark denotes an action that is COMPULSORY.
WARNING
• In the event of refrigerant leakage, be sure to keep away
2
.
from fire or any flammables, and consult authorized service
personnel.
• If you see lightning or hear thunder, there might be a lightning
7.74
strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch this product
or the power source during thunderstorm.
• The appliance shall be stored in a room without continuously
operating ignition sources (for example: open flames, an
operating gas appliance or an operating electric heater).
• The appliance shall be stored in a well-ventilated area.
• Be aware that refrigerants may not contain an odour.
• The appliance shall be stored so as to prevent mechanical
damage from occurring.
• Disposing of the product shall be done properly, in
compliance with national or regional regulations.
• During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
flammable gas to leak during operation).
CAUTION
(continued)
31-Mar-17 10:12:56
En-1

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASTG34KMTB

  • Page 1: Table Of Contents

    General Informations on Operation ........9 Cleaning and Care.............. 10 Troubleshooting ..............12 ASTG30KMTB ASTG34KMTB Before using this product, read these instructions thoroughly. Also, keep this manual for future reference, together with the installation manuals for the indoor and outdoor units. Safety Precautions To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the following safety precautions.
  • Page 2 Safety Precautions (continued) WARNING • This appliance is not intended for use by persons (including • Do not use inflammable gases near this product. children) with reduced physical, sensory or mental • Do not expose yourself directly to the cooling airflow for capabilities, or lack of experience and knowledge, unless many hours.
  • Page 3: Indoor Unit Overview And Operations

    AIR CONDITIONER Wall Mounted Type Indoor Unit Overview and Operations Intake grille Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing may have an effect on the proper function or performance of the product. "MANUAL AUTO"...
  • Page 4: Remote Controller Overview And Operations

    Remote Controller Overview and Operations CAUTION • To prevent malfunction or damage of the remote controller: • If leaking battery fluid comes in contact with your skin, eyes, or mouth, immediately rinse with plenty of clean water, and - Place remote controller at where will not be exposed to consult your physician.
  • Page 5 AIR CONDITIONER Wall Mounted Type Remote Controller Overview and Operations (continued) Signal transmitter 17 "RESET" button Aim at the signal receiver of the indoor unit properly. When you press the "RESET" button, press it gently by using the tip • Signal transmit indicator on the remote controller display shows of a ballpoint pen or other small object in correct direction as shown in that the signal from the remote controller is being transmitted.
  • Page 6: Timer Operation

    Timer Operation  Remote controller custom code setting Note for timer settings: Any interruption of the power supply, such as a blackout or cutting off When two or more air conditioners are installed in a room and the of a circuit breaker, makes the set internal clock go wrong. remote controller is operating an air conditioner other than the one you In such a case, the TIMER indicator on the indoor unit blinks, and wish to set, change the custom code of the remote controller to operate...
  • Page 7 AIR CONDITIONER Wall Mounted Type Timer Operation (continued) To set the WEEKLY timer, first follow steps ①~③ on page 6 WEEKLY timer for the ON/OFF timer. ON and OFF timer can be combined, and up to 4 reservations (program Select the program number and the day using the "SELECT" ) per day and 28 reservations per week.
  • Page 8: Human Sensor (Energy Saving)

    If the air conditioner is under demand controlling, consult the issues with your electricity supplier. If they are not demand controlling the air conditioner, refer to your warranty card for the contact details of Fujitsu General (AUST.) PTY LIMITED or visit our website : www.fujitsugeneral.com.au OPERATING MANUAL En-8 9387081145_OM.indd 8...
  • Page 9: General Informations On Operation

    AIR CONDITIONER Wall Mounted Type General Informations on Operation Automatic defrosting operation Heating performance When outdoor temperature is very low with high humidity, frost This air conditioner operates on the heat-pump principle, may form on the outdoor unit during the heating operation, and absorbing heat from air outdoors and transferring that heat it could reduce the operating performance of the product.
  • Page 10: Cleaning And Care

    Cleaning and Care CAUTION • Before cleaning the indoor unit, be sure to turn it off and all the power supply has been disconnected. • Before starting operation, make sure that the intake grille has been shut completely. Incomplete closing of the intake grille might have an effect on the proper working or performance of the air conditioner.
  • Page 11 AIR CONDITIONER Wall Mounted Type Cleaning and Care (continued) Air cleaning filter installation Replacing dirty air cleaning filters Replace filters with the following components (purchased separately). Open the intake grille and remove the air filters. • APPLE-CATECHIN FILTER: UTR-FA13-1 Air filter (Right & Left) •...
  • Page 12: Troubleshooting

    Troubleshooting WARNING In following events, immediately stop operation of the air conditioner, and disconnect all the power supply by turning off the electrical breaker or disconnecting the power plug. Then consult your dealer or authorized service personnel. As long as the unit is connected to the power supply, it is not insulated from the power supply even if the unit is turned off. •...

This manual is also suitable for:

Astg30kmtb

Table of Contents