Outlines And Dimensions - Mitsubishi Electric PLFY-P40VBM-E Technical & Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for PLFY-P40VBM-E:
Table of Contents

Advertisement

6

OUTLINES AND DIMENSIONS

PLFY-P32VBM-E.UK PLFY-P40VBM-E.UK
PLFY-P80VBM-E.UK PLFY-P100VBM-E.UK PLFY-P125VBM-E.UK
PLFY-P32VBM-E
.UK PLFY-P40VBM-E
1
PLFY-P80VBM-E
.UK
1
Ceiling hole
20~45
860~910
810
Fresh air
Suspension bolt pitch
160
intake hole
Transmission terminal block
Power supply
Branch duct hole
terminal block
For MA-Remote controller
terminal block
Suspension bolt
187.5
M10 or W3/8
840
1
60
284
2
*
*
Suspension bolt
lower edge
Power supply wire,
*
Indoor unit/Outdoor unit
connecting wire entry
Control wire entry
597
Air intake hole
M
Air intake
grille
M
500
Air outlet hole
950
Indoor unit
Ceiling
3000 mm or
more
Grille
Obstacle
1500 mm
or more
.UK PLFY-P50VBM-E
1
20~45
160
Drain pipe
connected to VP-25
377
*
*
*
*
Ceiling
Grille
Drain hole
Drain pump clean hole
and Drain emergency
drainage hole
M
Auto vane
(Air outlet)
M
Vane motor
83
36
Indoor unit
1800mm or more
from floor
For high
attachment
Floor
PLFY-P50VBM-E.UK
.UK
1
Detail connecting of branch duct(Both aspects)
90
[175
Branch duct hole
Burring hole pitch
Detail drawing of fresh air intake hole
(
)
Connected the attached
flexible pipe or socket.
Keep approximatety
10 to 15 mm space
between unit ceilling
and ceilling slab.
In case of standard grille : PLP-6BA
In case of auto-grille : PLP-6BAJ
In case of wireless remote controller : PLP-6BALM
Emergency operation switch<Cooling>
and Emergency Up/Down switch<Up>
Emergency operation
switch<Heating>and
Emergency Up/Down switch<Down>
DEFROST/STAND BY lamp
Receiver
Operation lamp
Note 1. Please choose the grille from a standard grille, auto-grille.
2. As for drain pipe, please use VP-25(O.D. [32 PVC TUBE).
Drain pump is included.
Max. lifting height is 850mm from the ceiling.
3. As for suspension bolt, please use M10 or W3/8. (Procured at local site)
4. Electrical box may be removed for the service purpose.
Make sure to slack the electrical wire little bit for control/power wires connection.
5. The height of the indoor unit is able to be adjusted with the grille attached.
6. For the installation of the optional high efficiency filter or optional
multi-functional casement.
1) Requires E or more space between transom and ceiling for the installation.
2) Add 135 mm to the dimensions * marked on the figure.
3) The optional high efficiency filter becomes optional multi-functional
casement and concomitant use.
7. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation and dripping may occur.
(It becomes the cause of dew drops/water dew.)
8. As for necessary installation/service space, please refer to the left figure.
Accessory ··· Drain socket (I.D. 32)
Flare nut 3/8 inch(For P50)
Flare nut 5/8 inch(For P50)
Flare nut 3/4 inch(For P100/P125)
1
Models
PLFY-P32,40VBM-E
Refrigerant pipe···[ 6.35
Flared connection···1/4 inch
PLFY-P50VBM-E
Refrigerant pipe··· [6.35 /[9.52
Flared connection
1/4 inch / 3/8 inch (compatible)
PLFY-P63,80VBM-E
Refrigerant pipe···3/8 inch
Flared connection···[9.52
PLFY-P100,125VBM-E
16
PLFY-P63VBM-E.UK
PLFY-P63VBM-E
1
Unit : mm
100
100
90
Cut out hole
*
350
14-[2.8
Burring hole
[150
Cut out hole
Burring hole
3-[2.8
Burring hole pitch
[125
Cut out hole
[100
*
Ceiling
Auto-grille
Air intake grille up/down distance
Ceiling
L.L Filter
Air intake grille
2
A
B
C
D
E
Refrigerant pipe ···[12.7
80
74
Flared connection···1/2 inch
Refrigerant pipe··· [12.7 /[15.88
Flared connection
87
78
400
241 258
1/2 inch / 5/8 inch(compatible)
Refrigerant pipe···[15.88
77
Flared connection···5/8 inch
85
Refrigerant pipe··· [15.88 / [19.05
Flared connection
281
298
81
440
5/8 inch / 3/4 inch(compatible)
.UK

Advertisement

Table of Contents
loading

Table of Contents