3.0 Installation

Thermostat may be configured to operate in conventional or heat pump modes. Use 18 AWG thermostat wire for all connections.
Wire connection terminals support20 -30 VAC.
Fan speed (only G signal active) is determined by the DIP switch setting.
The default vane position is determined by the DIP switch setting.
If configured for two-stage operation, fan speeds can be configured by DIP switch settings.
Auxiliary heater control is provided by CN24 connector on indoor units PC Board. The CN24 connector outputs 12VDC at 80mA. Please
consult a licensed technician to ensure proper set-up and safety of auxiliary heat source in accordance with auxiliary heat source
product documentation and local building codes. Please confirm CN24 availability in the indoor unit manual.
The device provides two mounting holes to mechanically affix the case to a solid surface. Double-sided tape may be used to affix the
device. When using tape, ensure that the tape is approved for use within the anticipated operating temperature ranges.
Install the transformer as per Canadian Electrical Code, Canadian building code and local codes compliance, and manufacturer's
installation instructions.
Connect the RMF-CA200-V2 cable to the connector CN105 on the indoor unit control board.
STEP 1: Select Single or Two-stage thermostat operation using DIP switch SW1-1
If Y2 or W2 is left unconnected or is unavailable from the thermostat set SW1-1 to the ON position. This configures single stage (simulated
VRF) operation of RMF-CA200-V2; simulating multiple stage operation using temperature differential based on W1 / Y1 call and run time.
OFF position (default)
ON position
STEP 2: Select Conventional or Heat Pump Mode using DIP switch SW1-2:
OFF Position (default)
ON Position

3.1 Single Stage and Two-Stage Conventional Connection Diagram

IM-RMF-CA200-V2-202306FM
Configured for Two-stage heating and cooling thermostats (Y1, Y2 & W1, W2)
Configured for use with Single-stage heating / cooling thermostats (Y1, W1)
Default - Configures conventional mode
Enables heat pump mode
© Mitsubishi Electric Sales Canada Inc. All rights reserved.
:
Thermostat Conventional Mode
Connections
Pin Signal
1
TC
Common (IN) Transformer
Common (OUT) To
2
C
3
TR
24 VAC (IN) Transformer
4
R
24 VAC (OUT) Thermostat
5
Y2
Stage 2 Cooling
6
Y1
Stage 1 Cooling
7
W2
8
W1
9
H
10
G
11
O
12
EO
Error Output (24 VAC OUT)
In single stage operation Y2, W2 signals are not
used
Description
Thermostat
Stage 2 Heat
Stage 1 Heat
Not Available
Fan
Not Available