-User programmable via keypad
-Allows any 1-6 digit access code
delay
-Remote exit time delay input from momentary SPST switch
The keypad must be programmed before it will operate. If the keypad contains no programming when powered up,
the yellow LED will flash rapidly. The user must enter the programming mode.
PROGRAMING MODE
To enter the programming mode, the following sequence of keys must be entered: *,0,0,*, then #. This is the
Programming Mode access code. During entry of the above keys, the yellow LED will turn off. If these keys are not
entered properly the yellow LED will again begin flashing rapidly awaiting the programming mode access code. If
the code is entered correctly, the yellow LED will pulse once. At this point, enter the desired 1-6 digit function access
code that will allow access to door functions, followed by the # key. For example, to enter function access code 1-2-
3, enter 1,2,3,#. The keypad will acknowledge by pulsing the yellow LED twice. Now enter the exit time delay
period, in seconds, followed by the # key (must be 10-60 seconds). For example, to program a 15 second delay, enter
1-5-# . The keypad is now programmed and will automatically enter the operating mode.
Note: If an invalid function access code is entered during programming (i.e., 7 digit code) the programming mode will
be exited leaving the previously stored function access code in place or returning to the power-up condition if no code
had been previously stored. Also, if an invalid exit time delay period is entered, the 10-second default value will be
used.
To access any door functions, the function access code must be entered followed by the "#" key. If the correct code is
entered, the yellow LED will flash three times. Any of the three functions can now be used.
1. To disarm the zone, press and release the "*" key.
2. To arm the zone, press and release the "#" key.
3. To initiate an exit time delay cycle, press and release the "0" key. The yellow LED will light for the duration of
the time period. During this time, the door may be entered/exited without causing an alarm and will re-arm
automatically at the end of the delay period again securing the door.
At anytime while in the operating mode, the exit time delay cycle can be initiated by momentarily connecting
terminals 3 and 4 of the keypad together with a SPST switch. Also, at anytime while in the operating mode, the
programming mode can be accessed to change the keypad programming by entering the programming mode access
code (see PROGRAMING MODE).
If power is removed from the keypad it will not function. However, its programming will be maintained for a
maximum of 48 hours. If power is restored within 48 hours (maximum), the keypad will automatically resume
operation. If power is not restored in time to preserve the keypads programming, it will need to be re-programmed
when power is restored.
A-1806D REMOTE CONTROL KEYPAD
-Allows remote arm and disarm functions
-Keypad programmable 10-60 second exit time
-48 hour (minimum) power-loss code retention
DA1806DPM
Need help?
Do you have a question about the A-1806D and is the answer not in the manual?
Questions and answers