LINOVISION IOT-S300AP Product Manual page 5

Barometric pressure sensor

Advertisement

Slave Address
Function
Starting Address Hi
Starting Address Lo
Data Hi
Data Lo
CRC Check Lo
CRC Check Hi
★Slave response:
Slave Address
Function
Starting Address Hi
Starting Address Lo
Data Hi
Data Lo
CRC Check Lo
CRC Check Hi
01H
Save address
06H
Function code
00H
The baud rate holding register address is 0014H
14H
The baud rate holding register address is 0014H
When the baud rate is 57600bps, the value of the register is
02H
576, which is 0x0240
When the baud rate is 57600bps, the value of the register is
40H
576, which is 0x0240
C9H
CRC check code lower 8 bits
5EH
CRC check code high 8 bits
01H
Slave address
06H
Function code
00H
The baud rate holding register address is 0014H
14H
The baud rate holding register address is 0014H
When the baud rate is 57600bps, the value of the register is
02H
576, which is 0x0240
When the baud rate is 57600bps, the value of the register is
40H
576, which is 0x0240
C9H
CRC check code lower 8 bits
5EH
CRC check code high 8 bits