Advertisement

Quick Links

Römi
Profi line 6.0
Instructions for use
®
Competence in fi lms
Version 07/2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Romi Profiline 6.0 and is the answer not in the manual?

Questions and answers

Summary of Contents for FVG Romi Profiline 6.0

  • Page 1 Römi Profi line 6.0 Instructions for use ® Competence in fi lms Version 07/2022...
  • Page 2: Table Of Contents

    FVG Folien-Vertriebs GmbH Contents Ebernhahner Str. 22 | D-56428 Dernbach / Germany Phone: +49 (0) 26 02 / 92 64 0 | Fax: +49 (0) 26 02 / 92 64 24 info@fvg-folien.de Introduction Page w w w. f v g- fol i en . de...
  • Page 3: Required Tools/ General Assembly Instructions

    WARNINGS Required tools (not supplied) • DANGER TO LIFE AND ACCIDENT RISK FOR CHILDREN AND INFANTS! • Protective/work gloves • Scissors • RISK OF SUFFOCATION! Never allow children to play with the packaging material or film • Sledgehammer • Trestle unsupervised! • RISK OF SWALLOWING and SUFFOCATION! Keep children and infants away from the • Pipe wrench •...
  • Page 4: Römi ® Profi Line Parts List

    Römi Profi line parts list ® Römi®Profi line individual push-fi t tubes Description Quantity for each standard version in the relevant length Beschreibung Römi 8 Römi 10 Römi 12 Römi 14 + 2 m Part A1 1.50 m, 8 x wind brace counterpart, 4 x door ridge, 4 x spacer for arch/ door post, cross purlin Part A2 1.30 m, door post lower section...
  • Page 5 Römi®Profi line parts overview Römi®Profi line individual push-fi t tubes Door bolt 4 door poles Manual soil drill adapter Part A1 Door hinge 32 mm bolt clamps Corner connector Part A1 Part B for door Part D Omega-shaped Omega-shaped clip Rounded head Ground anchor clip 32 mm...
  • Page 6: Römi ® Profi Line Assembly

    >2.00m and the arch spacing is For further information and queries contact us at +49 (0) 2602 9264-0 stated as 2m. or info@fvg-folien.de. When screwing the anchors into place, ensure that The sketch shows the soil conditions provide the necessary secure hold.
  • Page 7 Römi®Profi line · Arch with door and wind brace (fi rst and last arch) · Arch with wind brace (second and penultimate arch) · Centre arch Arch 1 = (with door) = 9 bolt clamps Arch 2 = 12 bolt clamps Arch 3 = 10 bolt clamps Arch 4 and subsequent/centre arches until third-last arch = 8 bolt clamps First thread on the bolt clamps, then connect the poles! The flat side of the bolt clamps...
  • Page 8 Step Step Assemble the arches and affi x the bolt clamps in place Mounting the wind brace WARNING! • First open just one bundle of arch parts because the individual parts were bent together. For that reason, only these parts can be connected to form a straight The wind brace is essential to the stability of the greenhouse.
  • Page 9 Step Door system Preparing and mounting the film • Affix the door ridge (part B + A1) to the first arch with two 32 mm bolt clamps. This is where the door posts will WARNING! be affixed. • To mount the door system, first hammer the poles for RISK OF CUTS and INJURIES! Always wear protective / work gloves when handling the pro- duct.
  • Page 10 To prevent mechanical damage only use the supplied omega-shaped clips. The omega-shaped clips may not be placed directly onto the greenhouse fi lm. Cut a piece of the protection fi lm off the roll (double the clip width) and place it under each clip before affi xing it in place.
  • Page 11 Step Step Tensioning with tension rope Finishing the door with fi lm General information: Surplus, protruding fi lm has to be turned inwards. CAUTION! RISK OF CUTS and INJURIES! Always wear protective / work gloves when handling the 2. Unwind the rope and throw product.
  • Page 12: Information About The Use Of Römi®Profiline

    Accessories Information about the use of Römi®Profiline Shading net: Hang the shading net over the tunnel and affix it with the tension • For efficient ventilation of the greenhouse you can gather up the film on rope (in the same way that you affixed the greenhouse film) to protect your the sides.
  • Page 13 Always repair • Loosen and remove the tension ropes. • Then loosen and remove the omega-shaped clips with the supplied pliers. tears immediately with FVG repair tape. Step Film Fold up the film on the long sides up to top of the arch.
  • Page 14: Warranty And Liability

    Check that the arch elements are still correctly positioned on the ground an- chors. Otherwise the other arches might fall over when you continue dismantling FVG accepts no liability for damages caused by incorrect assembly or poor the frame. care. These instructions for use have been compiled to the best of our knowl- Start to remove the wind brace between the first and second arch, and the edge and belief.
  • Page 15: Fvg Folien-Vertriebs Gmbh Ebernhahner Str. 22 | D-56428 Dernbach / Germany

    Close collaboration with institutes and universities Laboratory For further information about products contact: FVG Folien-Vertriebs GmbH Ebernhahner Str. 22 | D-56428 Dernbach / Germany Phone: +49 (0) 26 02 / 92 64 0 | Fax: +49 (0) 26 02 / 92 64 24 info@fvg-folien.de...

Table of Contents