7-4. HOW TO KNOW TO TEMPERATURE OF EACH THERMISTOR AT
OPERATING CONDITION.
Thermistor in tub : Press the [Delay End + Temp.] button.
Thermistor in dry duct : Press the [Delay End + Normal Dry] button.
7-5. ERROR DISPLAY.
・
If you press the START/PAUSE button when an error is displayed, any error except
and the machine will go into the pause status.
・
In case of
,
if the error is not resolved within 4 min., power will be turned off automatically and the error code will
blink. But in the case of
ERROR
WATER INLET
1
ERROR
UNBALANCE
2
ERROR
DRAIN
3
ERROR
OVER FLOW
4
ERROR
PRESSURE
5
SENSOR
ERROR
DOOR OPEN
6
ERROR
HEATING
7
ERROR
,
if the error is not resolved within 20 sec., or the in case of other errors,
, power will not be turned off.
SYMPTOM
・
Correct water level (248) is not reached within 8 minutes after
water is supplied or it does not reach the preset water level
within 25 minutes.
・
The load is too small.
・
The appliance is tilted.
・
Laundry is gathered to one side.
・
Non distributable things are put into the drum.
・
Not fully drained witnin 10 minutes.
・
Water is over flowing(under 21.3kHz).
※ If
automatically.
・
The SENSOR SWITCH ASSEMBLY is out of order.
・
Door not all the way closed.
・
Loose electrical connections at Door switch and PWB Assembly.
・
The DOOR SWITCH ASSEMBLY is out of order.
・
The THERMISTOR is out order.
CAUSE
is displayed, drain pump operates to drain water
15
will disappear