KCF technologies SMARTdiagnostics Product Manual

Iot hub

Advertisement

Quick Links

SMARTdiagnostics
®
IoT HUB Product Guide v.1.0
Last Edited: 5/4/2020

Advertisement

Table of Contents
loading

Summary of Contents for KCF technologies SMARTdiagnostics

  • Page 1 SMARTdiagnostics ® IoT HUB Product Guide v.1.0 Last Edited: 5/4/2020...
  • Page 2: Table Of Contents

    IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 Contents Revision History ............................3 Product Overview ..........................4 Introduction ..........................4 How It Works ..........................4 Applications ..........................4 Product Specifications ........................5 IoT HUB ............................5 2.1.1 Mechanical Specifications ..................... 5 2.1.2 Electrical Specifications ......................
  • Page 3: Revision History

    IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 Revision History Date Version Author Details 5/4/2020 R. Korte, E. Sankey Document Published P a g e...
  • Page 4: Product Overview

    When data is collected, it is transferred from the sensor to the HUB over-the-wire. The HUB subsequently transmits that data wirelessly to a base station or repeater (using DARTwireless™) which then sends it to SMARTdiagnostics software for analysis. While the ®...
  • Page 5: Product Specifications

    IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 at a different place in the cycle when it is. The HUB resolves this issue by allowing an external process to tell The HUB when the asset is running through trigger signals. Finally, it is desirable to collect other data from an asset in addition to vibration data.
  • Page 6: Environmental Specifications

    IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 Internal Connection Diagram: Environmental Specifications 2.1.3 Storage Temperature Range: -40ºC to 125ºC (-40ºF to 257º F) Operating Temperature Range: -40ºC to 85ºC (-40ºF to 185º F) IP Rating: IP67 Hazardous Certification: Class 1, Division 2 (planned) Wireless Radio Specifications 2.1.4 Radio: KCF DARTwireless™...
  • Page 7: Part Numbers

    IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 Part Numbers 2.1.6 The following variants are available for The HUB. Please use the complete part number for all components to ensure the correct product and configurations are shipped. SD-HUB-1-[magnet][power] Power Module Options: Magnet Options: Battery: B Magnet: M...
  • Page 8: Temperature Sensor

    IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 Temperature Sensor 2.2.4 Range: -40ºC to 125ºC (-40ºF to 257º F) Resolution: +/- 0.5ºC (+/- 1ºF) Part Numbers 2.2.5 The following variants are available for wired vibration sensor. Please use the complete part number for all components to ensure the correct product and configurations are shipped.
  • Page 9: Installation And Setup

    Installation of the HUB and wired sensors is conducted by trained Field Operations staff to ensure optimal performance for your HUB solution. Please refer to the Field Services Installation Guide for detailed installation instructions. Software Setup Procedures The software setup procedures for The HUB in SMARTdiagnostics are similar to those for V3 ® sensors.
  • Page 10 Intervals can range from 60 seconds up to 24 hours. Sampling Frequency – Select the appropriate Sampling Frequency from the dropdown list. Frequency can range from 64 Hz to 8192 Hz. IoT HUB Hardware Overview in SMARTdiagnostics IoT HUB Hardware Overview in SMARTdiagnostics 10 |...
  • Page 11: Collecting Long Burst Data

    Collecting Long Burst Data in SMARTdiagnostics Product Support, Warranty, and Certification Information KCF Contact Information If you need any assistance setting up and using your IoT HUB or SMARTdiagnostics system, ® please contact our team and we’ll be happy to help!
  • Page 12: Product Warranty And Return Policy

    Lasted Edited: 05/04/2020 Product Warranty and Return Policy KCF Technologies, Inc. (“Seller”) warrants that (i) all products (except spare parts, replacement parts and spare kits) shall be free from material defects in workmanship for a period of one (1) year from the date shipped from Seller’s distribution center; and (ii) all spare parts, replacement parts, and spare kits shall be free from material defects in workmanship for a period of ninety (90) days from the date of invoice issued by Seller or its authorized distributor.
  • Page 13 IoT HUB Product Guide v.1.0 Lasted Edited: 05/04/2020 designed to detect, avert, or prevent, or that such product may not be compromised, disabled, or circumvented; (iii) Seller has made no representations or warranties, express or implied, to Buyer or for Buyer’s benefit that contradict any of the foregoing; and (iv) “false alarms” and “false readings”...
  • Page 14: Certification Information

    This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body. Changes or modifications not expressly approved by KCF Technologies could void the user’s authority to operate the equipment. INDUSTRY CANADA STATEMENT The term IC before the Certification/Registration number only signifies that the Industry Canada technical specifications were met.

Table of Contents