Description
Refrigerated Drinking Fountain (Cooler) delivers chilled, clean potable drinking water. Water Cooler houses the refrigeration and delivers a
steady stream of water for direct drinking at the press of the pushbutton.
Ratings
Electrical: 230Vac, 50Hz, (See nameplate for Amperage), 1 phase.
Ambient Air Temperature: 50-100.4 °F (10-38 °C).
Water Pressure: 20-100 psig (0.14-0.69 MPa).
Maximum Water Temperature: 90 °F (32 °C).
Refrigerant: HFC-R134a
Definitions
DANGER
– Indicates death or serious injury will result if proper precautions are not taken.
WARNING
– Indicates death, serious injury or property damage can result if proper precautions are not taken.
CAUTION
– Indicates some injury or property damage may result if proper precautions are not taken.
Authorized Service Personnel – Factory trained personnel or personnel having working knowledge of electrical, plumbing and
machine (appliance) maintenance procedures.
Safety
DANGER
Please read these instructions completely before starting the installation or performing any service. Failure to follow the instructions and
safety precautions in this manual can result in serious injury or death.
After installation, keep these instructions in a safe location for future reference.
Electric supply must be identical in voltage, cycle, and phase to that specified on nameplate.
Electrical supply must have Ground Fault Circuit Interrupter (GFCI) protection.
A means for disconnecting electrical supply to the unit must be incorporated in the fixed wiring in accordance with wiring rules. This is to
allow electrical disconnection of the unit from electrical supply after installation.
WARNING
For use with clean, clear potable drinking water only. Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before the system.
Installation and connection to water and electrical mains must be in compliance with local and national laws.
All Installation and Service work must be performed by an authorized service personnel.
CAUTION
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory, or mental capabilities or
lack of experience and knowledge if they have been given supervision or instructions concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children
without supervision.
To prevent a metallic taste or increased metal content in the water due to an electrolysis process caused by electrical feedback from the
grounding of electrical equipment to water supply and water waste mains, connect to these mains using non-conductive materials. The
provided non-metallic In-line Strainer meets this requirement.
EFA8_2KJO
Original Instructions
Ingress Protection: IP21
For Indoor Commercial Use only.
Water Inlet: 3/8"O.D. unplated copper tube.
Waste Water Outlet: 1-1/4" O.D. tube
PAGE 1
1000003124 (Rev. A - 12/15)

Advertisement

loading

Summary of Contents for Elkay EFA8 2YJO Series

  • Page 1 EFA8_2KJO Installation / Care / Use Manual Original Instructions Models: EFA8*2YJO, EFA8*F2YJO, EFA8*P2YJO, EFA8*FP2YJO Description Refrigerated Drinking Fountain (Cooler) delivers chilled, clean potable drinking water. Water Cooler houses the refrigeration and delivers a steady stream of water for direct drinking at the press of the pushbutton. Ratings •...
  • Page 2: Installation: Electrical Connection

    EFA8_2KJO Installation For correct and safe installation, please read these instructions completely. DANGER • All Installation work must be performed by an authorized service personnel. • Disconnect electrical supply serving the Installation area to reduce risk of electrocution. • Unit not suitable for installations where water jets could be used. WARNING •...
  • Page 3: Operation: Start-Up

    EFA8_2KJO Rough-In: SCWT14A Figure 3 A = Water Mains Supply, 3/8” (9.5mm) O.D. compression outlet of Shut-off Valve (not provided) to be 1-1/2” (38mm) from Wall B = Waste Outlet, 1-1/4” (31.8mm) O.D. Drain Tube C = 1-1/4” (31.8mm) Trap (not provided) D = Electrical Mains Supply Duplex Outled, 3-wire in Recessed Box.
  • Page 4 EFA8_2KJO Service: Inspection/Cleaning • Inspect Cooler twice each year for proper operation and performance. • Inspection of the unit will require disconnecting electrical supply, removal of panels, etc. and reassembly and return to service practices. 1. Cleaning: Warm, soapy water or mild household cleaning products can be used to clean the exterior panels. Extra caution should be used to clean the mirror finished stainless steel panels.
  • Page 5 27165C 27147C Granite 27168C 27657C 27166C 27148C Light Gray For Replacement Parts, contact your local distributor or call 1.800.834.4816 Elkay Manufacturing Co. 2222 Camden Court – Oak Brook, IL 60523 U.S.A – 630.574.8484 1000003124 (Rev. A - 12/15) PAGE 5...

This manual is also suitable for:

Efa8 f2yjo seriesEfa8 p2yjo seriesEfa8 fp2yjo series