Shift Alarm Vibration Geo-fence Plug Out Alarm Low Voltage Voice Monitor Alarm Alarm 2.Specifications Model MV66 Weight Device Information Dimensions 48.2mm(L) * 28.6mm(W) * 29.1mm(H) Backup Battery 3.7V 60mAh Li-Polymer Battery Working Voltage DC 9V - 35V Working Current 12V/45mA...
GNSS Accuracy: <10M @ Open Sky GNSS Specifications Accurancy LBS Accuracy: 100-2000m (Depend on density of base stations) 3. Activate Device First Step: Prepare and Install SIM Card * If use your local SIM card, please make sure the SIM card already enabled SMS, internet data traffic, call and caller ID displaying functions;...
Note: The APN information is very important, it must 100% correct to match with the sim card of the tracker, if you configured wrong APN, the tracker also will reply "SET APN ok" but it will can't get online! 4. Package Content MV66 OBD Tracker User Guide Packing Box OBD Extension Cable(optional)...
Page 5
2. Set Data Upload Interval For example: TIMER,T1,T2# MV66 T1 ranges 0/5~18000 or 0(seconds), upload interval when ACC ON, 0 means no upload, default is 10; TIMER,10,3600# T2 ranges 0/5~18000 (seconds), upload interval SET TIMER OK when ACC OFF, 0 means no upload, default is 10;...
Page 6
6. Installation Recomendation Where is the OBD interface? Where is the OBD interface? Most of the car‘s OBD interface is located in A and B, Most of the car's OBD interface is located in A and B, A small part of the car will be in C,D and E. A small part of the car will be in C,D and E.
7. Trouble shooting Type Check the APN and settings. Unable to connect to Check whrther the data service of SIM card is enabled. tracking platform Check the balance of SIM card. Check whether external power is still connected. Tracker shows offline Check if the vehicle entered netword blind area.
Page 8
Functions Command Format Explanation NOTE: Reply message’s language is determined by Address Inquiry POSITION# device’s language setting, if get position content failed, device will reply Google Map location link. ID: ID number of the tracker IMEI: IMEI number of the APN:APN name,APN user,APN password, IP:Domain name and port number or IP address, port pumber...
RESTARTING...1 MINUTE WILL BE OK RESTART# APN,CMNET# (if no name & Password) APN,Network name APN,internet,internet,internet# (if with name APN Setting [,name,password]# & Password) If set with Domain Name: SERVER,1,d.micodus.net,7700# SERVER,1,Domain,Port# Server Setting If set with IP: SERVER,0,47.254.77.28,7700# SERVER,0,IP,Port# TRAFFIC,ON# OPEN TRAFFIC OK Internet...
Page 10
Functions Command Format Explanation Directly delete the number: SOS,D,1st number,2nd SOS,D,13800138000# Delete SOS number,3rd number# or Delete 1st number: SOS,D,1# Administrator SOS,D,1,2,3# Delete 2nd number: SOS,D,2# Number Delete the 2nd and 3rd number: SOS,D,2,3# CENTER,A,+8613800138000# CENTER,A,center NOTE: Please remember to add the country code as Center Number number# prefix with the cellphone number!
Alarm Setting Commands Functions Command Format Explanation Example: SPEED,ON,120,1# ( Means the speed limit is 120km/h and the alarm way is via SMS and Server ) A=ON/OFF, open or close over speed alarm, Overspeed SPEED,A,B,M# default: OFF Alarm Setting B=1~255(km/h), speed limit, default:100(km/h); M=0/1/2, way of alarm, 0 : SERVER only, 1: SERVER+ SMS, 2: SERVER+SMS+CALL;...