Page 2
PHK15H 15kW heat strip 36K/42K/48K/60K PHK20H 20kW heat strip 48K/60K IMPORTANT You must use a compatible heat kit listed in the chart above. Using an incorrectly sized heat kit could cause the unit to overheat and/or cause equipment damage. mrcool.com...
MRCOOL Safety Precautions Electric Heat Kit ® Preparation Before Installation 1.) Remove the upper side panel of the air handler. 2.) Remove the air duct sealing plate by removing the 4 retaining screws. Remove the 4 screws 3.) Knock out the covered hole on the front panel.
Page 4
4 prongs 2.) Reinstall screws to fasten the heat kit element to the air duct. Reinstall screws 3.) Fasten heat kit electrical board bracket to air handler by installing 2 screws. Position bracket and install screws Page 2 mrcool.com...
Page 5
NOTE: When installing the electrical installation board, pay attention to the indoor unit power cord and make sure it does not hang or snag on the sharp edges of the sheet metal heat kit bracket. Please refer to the image below. mrcool.com Page 3...
Page 6
6.) Reinstall the upper side panel. The switches for the heat kit should protrude through the hole you knocked out of the panel. Then, turn on the power and check operation. Page 4 mrcool.com...