REVERSING ANGEL HRA-6000 Series V5 User/Installation Manual HA - 280 PRO Guide to Intelligent Parking INSTALLERʼS MANUAL Manufacturer: COMMERCIAL ELECTRONICS CO. LTD 264 HAYDONS ROAD, WIMBLEDON, LONDON SW19 8TT. UK TEL: +44 020 8404 7105 FAX: +44 020 8404 7104 http://www.hawkcaralarm.com e-mail: info@hawkcaralarm.com Manufactured by Commercial Electronics Co.
Page 2
Introduction Reversing Angel Congratulation on your purchase of the HAWK HRA-6300 back up sensor, designed to aid Congratulation on your purchase of the HAWK HRA-6300 back up sensor, designed to aid Congratulation on your purchase of the HAWK HRA-6300 back up sensor, designed to aid...
How it works How it works The functions of the sensors depend on an ultrasonic signal that is transmitted by them. They calculate the distance between the object and the sensor by measuring the time it takes for the waves to return after reflecting on the object.
Page 4
Limitations Limitations The system could malfunction at theses temperatures: below -22 Fahrenheit (-30 Celsius) or above 176 Fahrenheit (80 Celsius). The sensors may not work if an object does not reflect the ultrasonic waves or it has an unusual shape, pole cardboard carton, tire of bicycle, small or slender tree, rectangular lumber or curbs tone. The sensor may not detect another vehicle bumper if itʼs too high.
Page 5
How to test How to test Warning: Do not stand behind a moving vehicle death or injury could occur. Apply the hand brake. Turn ignition on (Do not start the vehicle) Place the shift gear to reverse position. From behind the vehicle proceed to check the system by placing the palm of your hand slowly back and forth in front of each sensor.
Page 6
Maintenance Always keep sensor from dirt, snow and mud, clean them with a soft towel and low pressure water. Self-Test function (Model # HRA-5300L) The back-up system only activates when the vehicle is placed in reverse gear. When placed in reverse gear the system first does a diagnostic check to ensure the system is fully functional and reports any sensor malfunctions within the back- up system.
Installation Instruction Installation Instructions Note: Before installing system let the components of the exhaust system cool down. This will make the installation safer and preclude heat damage to the backup sensor wiring or components. Installation Diagram Installation Diagram The following illustration shows the general location of the components of the backup system.
Tools Sensor Installation Install the sensors vertically; the “UP” sign must be on Insert the plug into the socket and wind Install the sensors vertically; the “UP” sign must be on Insert the plug into the socket and wind the turn cap tightly. (Model # HRA-5300) upside.
Control Box Installation Wiring Installation for 4 Sensor Kit • Connect the Red wire of the control unit to the (+) positive wire of the vehicle reverse indicating light. • Connect the Black wire (-) to the vehicle’s chassis or negative of battery. Wiring Installation for 6 &...
Page 15
After installation Test After Installation Test Use the following to test and verify the operation of the backup system. Warning: Do not stand behind a moving vehicle death or injury could occur. Prior to testing, set the parking brake On, ignition key On (do not start), step foot on brake and shift the vehicle into reverse.
Page 16
HAWK dealer; the unit will be professionally reinstalled in the vehicle in which it was originally installed by an authorized HAWK dealer; and the unit is returned to HAWK, shipping prepaid with a legible copy of the bill of sale or other dated proof of purchase bearing the and the associated sensors and accessories, carry a one-year warranty from the date of purchase of the same.