ClimateMaster ACDU01 Operation Manual
ClimateMaster ACDU01 Operation Manual

ClimateMaster ACDU01 Operation Manual

Communicating service tool

Advertisement

Quick Links

Caution:
These instructions are intended to be used by the installer or service personnel. End users are NOT advised to change or
modify any of these settings. Doing so may cause the equipment to stop working properly and/or may void the warranty on
both the thermostat and the equipment.
ACDU01 Communicating

Table of Contents

Section
Title
1.0
2.0
3.0
3.1
3.2
3.3
3.4
3.5
3.6
4.0
4.1
4.2
4.3
4.4
4.5
5.0
Service Tool
Operation Manual
97B0106N01
Rev.: 10/23/12
Page
3
4
4
4
5
5
6
6
7
8
8
8
9
9
11
12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACDU01 and is the answer not in the manual?

Questions and answers

Summary of Contents for ClimateMaster ACDU01

  • Page 1: Table Of Contents

    ACDU01 Communicating Service Tool Operation Manual 97B0106N01 Rev.: 10/23/12 Caution: These instructions are intended to be used by the installer or service personnel. End users are NOT advised to change or modify any of these settings. Doing so may cause the equipment to stop working properly and/or may void the warranty on both the thermostat and the equipment.
  • Page 2 This page was intentionally left blank.
  • Page 3: Connection

    R e v. : 2 3 O c t . , 2 0 1 2 1.0 Connection ClimateMaster’s Communicating Service Tool (ACDU01) allows install and service technicians to confi gure and diagnose ClimateMaster Digital Communicating Units without installing a digital communicating thermostat.
  • Page 4: Menu Structure

    3.0 System Confi guration Use the System Confi guration option on the start-up screen to adjust critical equipment settings. The System Confi guration information will be automatically ACDU01 1.00 obtained from each communicating control in the system. SELECT OPTION Start-up Screen Note 1: The Airfl...
  • Page 5: Option Selection

    A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 OPTION SELECTION OPTION SELECTION This option allows the confi...
  • Page 6: Pump Configuration

    A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 PUMP CONFIGURATION VARIABLE SPD INTERNAL PUMP CONFIGURATION...
  • Page 7: Multi-Unit Configuration

    A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 MULTI-UNIT CONFIGURATION If multiple units are connected to one ATC thermostat upon unit start-up, the thermostat will automatically register the...
  • Page 8: Service Mode

    A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 4.0 Service Mode SERVICE MODE MANUAL OPERATION...
  • Page 9: Dipswitch Configuration

    A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 DIPSWITCH CONFIGURATION CONTROL CONFIGURATION DIPSWITCH S1...
  • Page 10 A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 4.4.0 Fault Conditions Menu FAULT CONDITION MENU LT1 LOW WATER TEMP...
  • Page 11: Clear Fault History

    A C D U 0 1 C o m m u n i c a t i n g S e r v i c e To o l R e v. : 2 3 O c t . , 2 0 1 2 4.4.3 Confi...
  • Page 12: Revision History

    97B0106N01 ClimateMaster works continually to improve its products. As a result, the design and specifi cations of each product at the time for order may be changed without notice and may not be as described herein. Please contact ClimateMaster’s Customer Service Department at 1-405-745-6000 for specifi...

Table of Contents