Download Print this page

ROOTS OIL 200 Operator's Manual

Oil recycling unit electric

Advertisement

Quick Links

OIL 200
Oil Recycling Unit
Electric
400V/50Hz
Read this manual completely and understand the
Operator's Manual
instructions before operating the machine.
OIL 200
"English Version"
1

Advertisement

loading
Need help?

Need help?

Do you have a question about the OIL 200 and is the answer not in the manual?

Questions and answers

Summary of Contents for ROOTS OIL 200

  • Page 1 OIL 200 Oil Recycling Unit Electric 400V/50Hz Read this manual completely and understand the Operator’s Manual instructions before operating the machine. OIL 200 “English Version”...
  • Page 2 OIL 200...
  • Page 3: Table Of Contents

    Blower No. - _______________________________ Installation Date - ___________________________ USER MANUAL ROOTS philosophy is to continually improve all of its products. For this reason we may modify the design, appearance and engineering of our products periodically. Therefore, some changes, modifications and improvements may not be covered in this manual.
  • Page 4: Introduc On

    The letter should be sent within 24 hours of receipt of machine comes with our Roots promise of quality, efficiency and the machine. performance.
  • Page 5: Intended Use

    It is designed to clean and collect liquids like oil/coolants with swarf, non- flammable materials in an indoor environment. Use only recommended filters/accessories. Do not use this machine in any other way other than described in this Operator’s Manual. OIL 200...
  • Page 6: Technical Specifica Ons

    Air Flow Delivery Flow Rate Container Capacity (Float cut-off) Liters Chip Basket Capacity (Theoretical) Liters Suction Inlet Filter Type OIL MIST Sound Level dB (A) Weight Dimensions - L x B x H 1460 x 660 x 1590 OIL 200...
  • Page 7: Safety Instruc Ons

    Maintenance jobs must always be performed with the Ÿ power plug detached from the power point. The employer must inform and train the user according to Ÿ the provisions of applicable laws. OIL 200...
  • Page 8 (rain, hail, check mechanical strength. snow, fog, dusts in suspension etc.) With an environmental Motor and burnt-out fuses must be replaced by Roots or running temperature between 5 C to 45 C and relative Ÿ...
  • Page 9 When replacing with a new power cord ensure the motor Ÿ rotation direction. If air is blown out of the exhaust port, the wiring is correct. (Ensure that this is checked during the commissioning of the machine) OIL 200...
  • Page 10 If the machine is moved on inclined grounds, you can risk to Ÿ lose the control, because of the weight and to damage persons or things. The machine must never be moved using a fork-lift or other equipment that lifts it off the floor. OIL 200...
  • Page 11 Read the Operator’s General Warning Caution Ecological Hazard Manual Do Not Use High Toxic Hazard Electrical Hazard No Smoking Pressure Jets Do not let powercord come in contact with Disconnect Powercord Electric Shock Hazard water or other fluids. OIL 200...
  • Page 12: Know Your Machine

    15. Suction hose 6. Chip basket top cover 16. Crevice nozzle 7. Suction valve 17. Rubber cone nozzle 8. Delivery tube assembly 18. Bend nozzle 9. Delivery valve 19. Wet floor nozzle 10. Fixed castor wheel 20. Extension pipe OIL 200...
  • Page 13 KNOW YOUR MACHINE DECALS ON THE MACHINE Suction/Discharge Changeover Sticker Top Cover Sticker MACHINE ORIENTATION Front Left Right Rear OIL 200...
  • Page 14: Machine Opera On

    NOTE F Before unpacking, carefully check the packaging for signs of damage. Report to authorized Roots Multiclean Ltd personnel immediately. F Upon unpacking, check for missing items or damaged parts. Report to authorized Roots Multiclean Ltd personnel immediately.
  • Page 15 Ensure that nobody including the operator modifies or alters the machine or any of its func on, doing so may cause fatal injury or death or it may damage the machine itself. g. Ensure that children do not operate the machine. OIL 200...
  • Page 16 Ensure that there are no flammable materials in the vicinity of the machine during vacuuming. Start-Up Test: By iden fying any problem before traveling to the worksite, you’ll save unnecessary travel me and will be able to make repairs more easily with the proper tools. OIL 200...
  • Page 17 Note: Before vacuuming, ensure that the chip basket is not completely filled. Caution: Red indicator lamp will glow if the changeover valve lever (e) is not set in “SUCTION” position during initial machine power. In this event, change the lever position to “SUCTION” before starting the machine. OIL 200...
  • Page 18 The machine is equipped with a Pressure Relief Valve (PRV) to vent out excess air during discharge, ensure that the PRV is not covered with any foreign object or tampered with. WARNING PRV setting is done at factory. Do not tamper or modify. OIL 200...
  • Page 19: Maintenance

    Please contact your local Roots Multiclean Ltd. dealer. The CLEANING OR SERVICING THE MACHINE. people there will be glad to perform that work for you. Their well trained personnel and genuine Roots spare parts are at your disposal. DANGER In case of any inquiry or order for spare parts, please always quote the machine's serial number mentioned on the nameplate.
  • Page 20 Remove any swarf from the chip basket filter and dispose latches. them in an appropriate way. Clean the chip basket filter with fresh water. WARNING Replace the chip basket top cover (b) and secure with latches Blower top cover is heavy, additional manpower is necessary. (a). OIL 200...
  • Page 21 Control Panel TIGHTNESS CHECK IMPORTANT: All electrical repairs should be done by Hoses: authorized Roots Mul clean Ltd. service engineer ONLY. Ensure that the connec ng hoses are in good opera ng condi on. STORING THE MACHINE If the hoses are damaged, cracked or broken, they must be replaced.
  • Page 22 Use a damp sponge with mild detergent to clean the exteriors of the machine. Ensure that water does not enter any electrical part. WARNING DO NOT CLEAN THE MACHINE BY MEANS OF VAPOUR JET OR HIGH PRESSURE CLEANING EQUIPMENT. WARNING: Disconnect power cord. OIL 200...
  • Page 23 Changeover valve position Check changeover valve position according to improper. the operation performed. Filter is clogged. Clean/Replace it. Chip basket is full. Empty chip basket. Machine performance has decreased Leak in hoses. Replace hoses. Worn gasket/seals. Replace gasket/seals. OIL 200...
  • Page 24 û Do not use the machine for vacuuming explosive, hot material and flammable liquids. û Do not operate the machine with bare foot. û Do not do any kind of service, except Roots authorized representative. û Do not use the machine, if any abnormal sound is noticed in the suction turbine.
  • Page 25 OIL 200...
  • Page 26 Roots Multiclean Ltd. R.K.G. Industrial Estate, Ganapathy, Coimbatore - 641 006, India. Phone: +91 (422) 4330 330, E-mail: rmclsales@rootsemail.com Web: rootsmulticlean.com OIL 200 Toll Free: 1800 41 99 77 9...