Download Print this page

NANO SEP 2500 ST Installation Manual

Advertisement

Quick Links

installation manual
SEP 2500 ST
service indicator - assembly and a achment
(b)
(a)
Insert the boss on the reverse
i
of the mount (c) into the pre-
drilled hole in the separator lid.
Peel backing from mestrip (a)
ii
and a ach to the plas c card
(b) within the do ed lines.
Flex the card, passing the ends
iii
through the slots on the top
surface of the mount.
(c)
To ac vate, press fi rmly on
the mestrip label at the point
indicated.
A er a few minutes, a red line
will appear, to indicate ' me in
service' up to 12 months.
A replacement card and me-
strip will be supplied with each
service kit.
Before star ng assembly, please check
1
contents are as follows:
2 white felt fi lter with black tube
4 STERLING fi lters
1 connec ng yoke (large blue fi gure 8)
1 test bo le
4 metal retaining springs (460 mm)
2 1250 ST towers
2 lids (only one drilled)
service interval kit containing:
molded plas c mount + screw
printed card
self-adhesive mestrip
fi ng kit containing:
2 straight adaptor 15 mm x 1/2" BSP
2 blanking plugs - large
4 elbow 15 mm
1 assembled por ng block
6 por ng block small blanking plugs
4 all-thread screws (M5 x 102 mm)
8 sleeve nut ends (M5 x 9 x 20 mm)
3 stem adaptors
2 reducing bushing
1 t-piece
2 grab taps
2 black tube 200 mm x 15 mm dia
2 blue tube 265 mm x 15 mm dia
general installa on notes
• Please ensure a steady fall in the
pipe run from the outlet point to the
sanitary drain.
• When used in conjunction with
timed solenoid drain, set drain "open"
duration to minimum setting (1-2
seconds).
• When used in conjunction with
motorized ball valve or high capacity
drain (ie Drain-all®) a de-pressur-
ization chamber must be installed
between drain and Sepura unit.
• Never discharge condensate to a
storm drain or to suface water; always
connect to a sanitary drain or sewer.
• Remember that it's the user's
responsibility to check with the local
authority as to the permissible dis-
charges in their area.
tes ng quality
Replace fi lters before
outlet cloudiness
exceeds the ppm limit
for your region.
Test outlet quality
weekly using kit
provided.

Advertisement