CONTENTS About This Manual Products Covered by This Manual Target Group Symbols Used Storage of the Manual Safety Important Safety Instructions Response to Emergency Situations Limitation of Liability Scope of Delivery Product Appearance Mounting Environment Requirements Battery Installation Orientation Battery Installation Electrical Connection Battery Power Connection BMS Communication Connection...
1. About This Manual 1.1 Products Covered by This Manual Livoltek Residential Energy Storage Battery Series: BLF48100.R110 1.2 Target Group This manual is intended for a qualified electrician. Any electrical installation and maintenance on the battery must be performed by qualified electricians in compliance with standards, wiring rules or requirements of local grid authorities or bodies.
2. Safety The manual describes the installation, commissioning, maintenance of the battery. Please read it carefully before operating. To prevent personal injury and property damage and to ensure long- term operation of the product, please read and follow all the instructions and cautions on the battery and this user manual during installation, operation or maintenance at all times.
2.2 Response to Emergency Situations Leaking Batteries If the battery leaks electrolyte which is corrosive, avoid contact with the leaking liquid or gas. Direct contact may lead to skin irritation or chemical burns. If one is exposed to the leaked substance, do these actions: •...
Any product damage or property loss caused by the following conditions LIVOLTEK does not assume any direct or indirect liability. • Product modified, design changed or parts replaced without LIVOLTEK authorization; • Changes, or attempted repairs and erasing of series number or seals by non LIVOLTEK technician;...
3. Scope of Delivery Item Designation Battery Mounting Bracket Screws for Fixing Mounting Bracket User manual 1 pair Parallel Power cable- positive & negative, 4AWG; Communication cable ;Double RJ45 plug; MSDS report documents Accessories for different applications may be different.
4. Product Appearance Thank you for choosing the LIVOLTEK battery. The BLF48100 Series is a series of Low Voltage Lithium-ion battery. It is designed for battery residential energy storage system. It must only be connected with a officially tested inverter (Hybrid or Off-Grid series).
Page 10
Table 1-2 Ports and terminals Label Name Grounding terminal Set Communication terminal resistor Dry contact Two-channel dry contact port COM IN Network port for parallel connection COM OUT Network port for parallel connection Power Display the power ON/OFF status of the battery Display the running status of the battery Display the alarm status of the battery...
5. Mounting 5.1 Environment Requirements It is recommended to install the battery into a cabinet and place it indoor. If you install it outdoor, select a cabinet with a sufficient IP rating. Build sunshade & rain shelter to avoid direct exposure to sunlight and rain for outdoor application. Keep children away from the equipment.
5.2 Battery Installation Orientation The battery supports stackable installation with brackets. At most 4 batteries can be athwart stacked. Ensure that you install the battery in correct directions. Please refer to figures below (√ means acceptable and X unacceptable).
5.3 Battery Installation 5.3.1 Unpack and Check for Transport Damage Unpacking the battery package and make sure the battery is intact during transportation. If there are some visible damages, such as cracks, or missing, please contact your dealer immediately. 5.3.2 Procedure for Stackable Installation STEP 1: Battery check Check and confirm the battery is powered off and battery breaker is turned off before any process.
Page 14
STEP 4: Stack battery packs with brackets At most 4 battery packs can be stacked in this way.
6 Electrical Connection 6.1 Battery Power Connection Battery connection diagram Procedure: Before connecting the power cables, please check and confirm the battery is powered off and battery breaker is turned off .
Procedure: STEP 1: •Please assemble the connectors if they are not pre-assembled. STEP 2: •Use an M4 screw to fasten the grounding wire to grounding terminal and fix the other end to the specified position . Step 3: • Install the connectors to battery power ports; make sure the polarities are correct.
6.3 Parallel Connection of Multi-batteries Expandability: Up to 16units of BLF48100 can be parallel connected in one system. Parallel Connection Diagram Procedure: STEP 1: Assemble the connectors to wire • Please assemble the connectors if they are not pre-assembled. STEP 2: Connect network cables •...
Page 19
STEP 4: Connect power wires • Connect the +/– terminals of each battery with power cables in the accessory box. • Then connect the + terminal of the uppermost battery, and - terminal of the bottom battery to the inverter.
7 Operating of the Battery 7.1 LED status indicator Green Green Battery status POWER ALRM LED4 LED3 LED2 LED1 Power off 75%≤SOC≤100% Standby 50%≤SOC<75% 25%≤SOC<50% 10%≤SOC<25% 0%≤SOC<10% SOC=100% Flashing 75%≤SOC<100% Charging Flashing 50%≤SOC<75% Flashing 25%≤SOC<50% Flashing 10%<SOC<25% Flashing 0%≤SOC≤10% 75%≤SOC≤100% 50%≤SOC<75% Discharging 25%≤SOC<50%...
7.2 COM IN/OUT Definition Pin No Definition PCS_CAN_H PCS_CAN_L BMS_485_A BMS_485_B PCS_485_A PCS_485_B 7.3 Turn On/Off the Battery •When turn on the battery, turn on the DC breaker. •When turn off the battery, turn off the DC breaker.
8 Technical Data Electrical Data BLF48100 Cell Type Total Energy 4.8kWh Depth of Discharge Usable Energy 4.3 kWh Nominal Voltage 48 V Nominal Capacity 100 Ah Operating Voltage Range 37.5-54.75 V Max. Charge/Discharge 100A/100A Current@25℃ Max. Parallel Number 16 Units...