  • Page 1 Version 1.4  User Manual  Terminals  VMT6008 ...
  • Page 2 VMT6008 Index  1  Remarks  3      Relevant Documentation for this device      Used Symbol Explanation      Data, Figures, Modifications      Trademarks      Copyright      Environmental Conditions      Standards      Equipment Versions      Scope of Delivery  2  Notes on Operation & Safety  7      Operation Location     ...
  • Page 3: Table Of Contents

    VMT6008 6  Interfaces  22      Interface Setup      24V DC Power Supply      Autostart (S1)      Speakers      USB‐Interface      PS/2 Interface      Netzwork Connection (RJ45)      Optional Radio Network Card      Serial COM Interface (RS232)  7  Drives  30  8  Software‐/Driver‐Installation  31      Configuration Center ...
  • Page 4 VMT6008 1 Remarks  1.1 Relevant Documentation for this device  The following documents are essential for setting up and operating this device:  User Manual (This Documentation):  Contains information for installation, commissioning and operating the device along with technical data of the  device hardware.  Qucik Start Guide:  Quick Install Guide for fast commissioning.  1.2 Used Symbol Explanation      Warning:  The "Warning" symbol refers to activities which might cause personal injury or  damage to the hardware or software!    Note:  The "Note" symbol familiarises you with conditions to be observed in order to  ensure flawless operation. Additionally, hints and advice are given for a more  efficient use of the device and for software optimisation.    1.3 Data, Figures, Modifications  All texts, data and figures are non‐binding. We reserve the right of modification in accordance with technological  progress. At that point in time when the products leave our premises, they comply with all currently applicable  legal requirements and regulations. The operator/operating company is independently responsible for  compliance with and observance of any subsequently introduced technical innovations and new legal  requirements, as well as for all usual obligations of the operator/operating company    1.4 Trademarks   It is hereby notified that any software and/or hardware trademarks further to any company brand names as  mentioned in this User’s Guide are all strictly subject to the various trademark, brand name and patent  protection rights.    Windows®, Windows® CE are registered trademarks of Microsoft Corp.  Intel®, Pentium®, Atom™ , Core™2 are registered trademarks of Intel Corp. ...
  • Page 5 VMT6008 1.5 Copyright  This manual, including all contained figures, is protected by copyright law. Any use for third parties non‐ compliant with the copyright provisions is prohibited. Any reproduction, translation as well as electronic and  photographic archiving and modification shall only be permitted after explicit written authorisation by ads‐tec  GmbH.    Any party in violation of this provision shall be obliged to damage compensation.    1.6 Environmental Conditions  The device may be operated under the following conditions. Failure to observe these specifications will  terminate any warranty for this device. Ads‐tec cannot be held liable for any damages arising due to improper  use and handling.   Temperature for devices without a heater  in operation   ‐20 ... 55°C  for storage    ‐30 ... 60°C     Temperature for devices including a heater   in operation   ‐30 ... 55°C  for storage    ‐30 ... 60°C     Humidity:  In operation    10 … 85% without condensate  For storage     10 … 85% without condensate     Vibration resistance ...
  • Page 6 VMT6008 1.7 Standards  This device complies with the requirements and protective aims of the following EC regulations:  Standards   This device meets the test requirements for granting the CE sign according to the  European test standards EN 61000‐6‐4 and EN 61000‐6‐2   This device complies with the test requirements in accordance with EN 60950  (VDE0805, IEC950) "Safety of Information Technology Equipment"   The device meets the EN 60068‐2‐6 test requirements (sinus excitation).   This device meets the EN 60068‐2‐27 test requirements (shock resistance test)    Note:  A respective conformity declaration for the authority in charge is available at the  manufacturer and may be viewed on request.  All connected components, as well as cable connections must also meet these  requirements for compliance with the EMC legislation. For this reason, screened  bus and LAN cables including screened connectors must be used and installed  according to the instructions in this user manual.    Note:  By using the CE conformity declaration in this document, you can find detailed  information about the standards applicable to this device.    Warning:  This is equipment of class A. This unit might cause radio interferences in living  areas; in this case the operator might be obliged to take suitable protective  measures at the operator’s expense    1.8 Equipment Versions  The system is available in two equipment versions:  Platform including a Flash SSD:  Platform without any rotating mass storage medium (hard disc, etc.) and with an embedded operating system  (Windows CE 6.0 / XP embedded) for stationary use with a standard Ethernet or with radio networking cards  installed on moving commissioning / forklift equipment. ...
  • Page 7 VMT6008 1.9 Scope of Delivery  Please check that all of the following components are contained in the packaging:    Scope of Delivery VMT6000 series   1 x device   4‐pin Lead‐through connector from Phoenix Contact, COMBICON MC 1,5/4‐STF3.81   Service CD    Protective covers    Optional scope of delivery:   Operating system   Installation kit      © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 8 VMT6008 2 Notes on Operation & Safety  This device contains electrical voltages and extremely sensitive components. Intervention by the user is only  designated for establishing the required cable connections.  The manufacturer or a service partner authorised by  the manufacturer should be consulted if you plan to make further modifications. Before beginning any works on  this device, it must be disconnected from the power supply. Suitable measures for avoiding any electrostatic  discharges towards components must be taken. If the device is opened by an unauthorised person, hazards for  the user might arise and any warranty claim will cease.  General Instructions    All users must read this manual and have access to it at all times   Installation, commissioning and operation may only be carried out by trained and  qualified staff   The security instructions and the manual itself must be observed by all persons who  work with this device   At the location of use, the valid guidelines and regulations for accident prevention  must be observed   The manual contains the most important instructions on how to use this device in a  safe way   Appropriate storage, proper transport, installation and commissioning, as well as  careful operation are prerequisites for ensuring safe and proper operation of this  device   The device can be cleaned by using a soft cloth and a commercially available glass  cleaning agent (e.g. Sidolin) with low alcohol content.    Warning:  Any installation works on the device are only permitted if the power supply is switched  off, and handling the device is safe.    2.1 Operation Location  The VMT control system is designed for use on support arm systems or on moving transport equipment (like  commissioning trolleys, forklifts or similar). You have to take care that the environmental conditions specified in ...
  • Page 9 VMT6008   2.2 Damage Caused By Improper Use  This device must immediately be shut down and protected from any accidental commissioning if the operating  system shows any obvious damage caused by, for example, improper operating or storage conditions, or by  improper use or handling.  2.3 Warranty / Repair  During the warranty period, any repair must only be carried out by the manufacturer or by a person authorised  by the manufacturer.    2.4 Treatment and Disposal of Lithium Batteries  This device contains a lithium battery for supplying the system clock with power as long as the supply voltage is  not connected. The battery has a life cycle of 3 ‐ 5 years depending on which load is applied.    Note:  The more the battery is exposed to higher temperatures, the faster it ages.   Warning:  There is an acute risk of explosion should the wrong type of battery be used.    Warning:  Do not put lithium batteries into a fire, do not solder on the cell body, do not recharge  them, open them, short‐circuit them, do not reverse their polarity or heat them up over  100°C; dispose of them properly and protect lithium batteries from direct sun light,  humidity and condensation.  Lithium batteries may only be replaced by the same type, or by a type recommended by the manufacturer.  The lithium battery must be disposed of according to the local legislation at the end of its life cycle.  2.5 Notes on Safety    Warning:  Installation works at the device are only permitted if the device is disconnected from the  power supply and protected from accidental switch‐on.      Note:  Always adhere to the safety measures applicable when handling components at risk of ...
  • Page 10 VMT6008 3 Mounting  3.1 External Device Dimensions VMT6008    Abb. 1:   © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 11 VMT6008 4 Commissioning  The power supply connection and interfaces of this device are installed underneath a protective cover. This cover  has to be removed in order to connect the power supply lead and the interface cables.   All supply leads and all required data leads have to be connected before commissioning. All supply leads and all  required data leads have to be connected before commissioning.    Warning:  The device must be switched off before connecting or disconnecting any cables in order to  prevent damage to the electronics!  The device may only be switched on after acclimatising to the ambient temperature in  order to avoid condensate accumulation. Make sure to meet the permissible voltage  requirements for this device.  After switching off and before switching on you must wait for at least 5 seconds.    Note:  The screen of a data cable must always be connected with the connector housing (EMC).  Under the embedded operating system, interfaces must explicitly be enabled and  required drivers must be installed in order to be able to use them. 4.1 Available Interfaces    Abb. 2:       © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 12 VMT6008     Note:  If the case is connected with earth potential at the provided PE contact (e.g. by connecting  the PE contact with the device plug), the electrical insulation is no longer given. This also  applies if the device is installed by using a metal retainer clip.  If you want to have the device electrically insulated from the power supply, you  have to use a method of installation that ensures appropriate insulation.   Pos: 18 /Datentechnik/Inbetriebnahme/Reihenfolge der Inbetriebnahme/Reihenfolge der Inbetriebnahme für VMT 60xx-Serie @ 1\mod_1222073159179_6.doc @ 4100 @ 4.2 Order of Steps during Commissioning  Removing the Lid from the Service Slot  Loosen the undetachable screws on the service slot cover by using a Torx Tx10 wrench and subsequently remove  the service slot cover from the device.    Abb. 3:   Connecting The Cables  Please connect all required cables. Use grommets in this case, in order to install the cables correctly and to avoid  any potential damage to the cables.    Note:  A cable installation kit, which includes grommets for several cable diameters, is  available as an option.   ...
  • Page 13 VMT6008 Abb. 4:       Warning:  The indicated protection class is only fully guaranteed if the case cover is correctly  installed!    Pos: 19 /Datentechnik/Inbetriebnahme/Betriebsbereitschaft prüfen/Betriebsbereitschaft prüfen für OPC/CPC/PLC/OTC/ITC/VMT-Serie(+Monitore) / IPC 5100/5500/2400/1100 @ 0\mod_1158905578361_6.doc @ 381 @ 4.3 Check for operational Readiness  Check the device for any hidden damage potentially caused by improper transport, operating or storage  conditions or by improper use or handling (e.g. smoke development from the device, etc.). If any damage is  detected, the device must be put out of service immediately and protected from accidental switch‐on.      © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 14 VMT6008 5 Operation  5.1 Frontkeys Control Keys  Abb. 5:   Version 1 (State until Q1/2010)  ON / OFF pushbutton of the device (ATX functionality) The operating  system is shut down, but the device is not disconnected from the input  voltage.    Depending on the actual equipment version, each device is equipped with an operating system  (Windows CE 6.0, Windows XP embedded or Windows XP Professional) ex works, and a soft  keyboard is installed. The keys on the front panel are pre‐allocated with the following functions by  a specific driver in the soft keyboard:  Level 1:  Activate and deactivate the soft keyboard for letter/character input by  using the touch screen.     Level 2:  Increase the volume of the internal speakers  Level 1:  Change task (Alt+ESC) in Windows.  Level 2:    Decrease the volume of the internal speakers.  Level 1:  Not allocated. The configuration of this level can be customised by  programming via the soft keyboard programme    Level 2:  Increase display brightness.  Level 1:  Right mouse‐key function.  Level 2:    Decrease display brightness.  Shift key (SHIFT) for activating the second keyboard level. This key must  be pressed simultaneously with the desired function key.   ...
  • Page 15 VMT6008   Note:  If the software keyboard is not installed, only the functions for display settings and  volume control are active. When changing the values, no representation is visible  on the screen. The key functions can have been previously modified in accordance  with customer specific requirements. The above described functions are pre‐set ex  works.    Version 2 (State from Q2/2010)  ON / OFF pushbutton of the device (ATX functionality)   The operating system is shut down, but the device is not disconnected  from the input voltage.  Depending on the actual equipment version, each device is equipped with an operating system  (Windows CE 6.0, Windows XP embedded or Windows XP Professional) ex works, and a soft  keyboard is installed. The keys on the front panel are pre‐allocated with the following functions  by a specific driver in the soft keyboard:  Level 1:  Activate and deactivate the soft keyboard for letter/character input by  using the touch screen.   Level 2:  Decrease display brightness.  Level 1:  Change task (Alt+ESC) in Windows.  Level 2:  Increase display brightness.  Level 1:  Not allocated. The configuration of this level can be customised by  programming via the soft keyboard programme  Level 2:  Decrease the volume of the internal speakers.  Level 1:  Right mouse‐key function.  Level 2:  Increase the volume of the internal speakers  Shift key (SHIFT) for activating the second keyboard level. This key must  be pressed simultaneously with the desired function key..  © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 16 VMT6008   Note:  If the software keyboard is not installed, only the functions for display settings and  volume control are active. When changing the values, no representation is visible  on the screen. The key functions can have been previously modified in accordance  with customer specific requirements. The above described functions are pre‐set ex  works.   Pos: 21 /Datentechnik/Bedienung/Softkeyboard/Softkeyboard für VMT 60xx @ 1\mod_1228750145198_6.doc @ 4251 @ 5.2 Softkeyboard  If an operating system is installed ex works, the soft keyboard is also preinstalled. If the operating system is  delivered separately with the device, the soft keyboard must also be installed on site. By using the soft keyboard,  data can be entered via the touch screen like with an external keyboard.  Abb. 6:   © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 17 VMT6008 How to operate the Soft Keyboard from Version 3.11::  Activate and deactivate the soft keyboard for letter/character input using  the touch screen  Switches numeric keys on and off (only if numeric keys are visible)  Switching between different representations (Alphanumeric keys   Numeric keys  Function key bar)  Soft keyboard representation, zoom in  Soft keyboard representation, zoom out    Note:  If a function is to be activated which requires pressing two keys at the same time  (e.g. Alt + F4), these keys have to be pushed one after another at the soft keyboard,  and the special keys Shift, Alt and Ctrl must always be pushed first.  Due to differences in programming of a large variety of software programmes, we  cannot ensure that the soft keyboard works properly with all available software.  When deactivating the soft keyboard, the previously active state (alphanumeric /  numeric keys or function keys) will be stored and will be displayed when re‐ activating the keyboard. Pos: 22 /Datentechnik/Bedienung/Touch Screen/Touch Screen für VMT 60xx @ 1\mod_1246361069977_6.doc @ 5853 @ 5.3 TouchScreen  The control system is equipped with a touch screen monitor. The touch screen monitor is internally connected  with the USB interface. The driver software required for using the touch screen is integrated in the  corresponding operating system, or can alternatively be installed from the enclosed service CD.  Pos: 23 /Datentechnik/Bedienung/Status-Anzeigen/SYS-LED/SYS-LED für VMT60xx-Serie @ 2\mod_1260525540269_6.doc @ 6876 @  ...
  • Page 18 VMT6008 5.4 Status Indicators  SYS‐LED (Bicoloured)  Depending on the colour and type of flashing, different device states are displayed by the SYS LED.  Abb. 7:   Folgende Signale werden dargestellt:  System‐LED Indicators  Behaviour  Description  static  Device is connected with a power  source and switched on.    flashing  Volume / display brightness is being  modified    static  Minimum / maximum value for  volume / display brightness is  reached.    Lightsensor  static  Brightness adaptation depending on  the received light intensity with  automatic setting    Pos: 24 /Datentechnik/Sondergeräte-Module/VMT6000-Serie/RFID-Reader für VMT6000-Serie @ 2\mod_1260527463758_6.doc @ 6885 @ © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 19 VMT6008 5.5 RFID‐Reader (optional)  By using the RFID reader, passive RFID TAGS (RFID chip / key card) are available for automatic system login. The  user applies the RFID tag like a key and requires neither user name nor password.   For authentication, the key card or the RFID chip are held in front of the position highlighted in the figure. The  information from your key card or RFID chip is read and evaluated by the device. The VMT6000 series uses Mifare‐, and LEGIC Technology.       Abb. 8:         © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 20 VMT6008 5.6 RFID‐Configuration    The equipment is pre‐configured to test the RFID functionality without configuration.      Note:  Check the functionality of your RFID reader through the following steps before  starting the commissioning of a software to exclude any transport damage or other  error sources.   Depending on the hardware configuration a MIFARE or LEGIC RFID reader is installed.  MIFARE  1) To test the RFID function, select the application "ads‐tec RFID sample application" on the pre‐installed  Configuration Center.    Ads‐tec RFID‐Reader Tool  The configuration of the application starts automatically, by launching the application which searches on all COM  ports to the RFID reader.    Abb. 9:     If an RFID reader is detected,it is interrogated cyclically whether a serial number (CSN) was read. It generates a  transponder serial number which is output directly to the surface.      © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 21 VMT6008   Abb. 10:     If no RFID reader is found,you have the opportunity to select the serial port to which the RFID reader is  connected manually.  Abb. 11:     After selection of the COM port, the application opens the por whicht is now ready to receive data. A  transponder data are output in the surface.      © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 22 VMT6008 LEGIC  1) To test the RFID function, select a suitable editor (Notepad, Word) and hold the RFID tag  to the RFID reader. This information will be issued.    Note:  The output data can be pre customized   in consultation with ads-tec 5.7 COMInput‐Configuration  The Application COMInput converts the data received over a serial interface, in key sequences and feeds it then  place in the Windows operating system. Thereby it is possible that the data of an RFID reader or a bar code  scanner arrive automatically without the active application.  Abb. 12:     The functionality of the application can be integrated via the Configuration Center surface at any time on or off.  The serial‐to‐use interface can be selected from the list of existing interfaces for activation of the service.      Note:  Baudrate: 9600/ Databits: 8/ Stopbits: 1/ Parity: None/ FlowControl: None     Note:  If the functionality of the RFID reader has been tested, the corresponding port has  to be disabled and then enabled again,  otherwise it may cause a malfunction. Pos: 25 /Datentechnik/Schnittstellen/Schnittstelleneinstellung/Schnittstelleneinstellung für VMT-Serie / PLC 500 @ 0\mod_1158916296612_6.doc @ 517 @  ...
  • Page 23: 6  Interfaces

    VMT6008 6 Interfaces  6.1 Interface Setup    Interface  IRQ  Adress  COM1  4  3F8h  RFID (Touch)  3  2F8h    Pos: 26 /Datentechnik/Schnittstellen/Spannungsversorgung/Spannungsversorgung für VMT60xx-Serie @ 2\mod_1260450284020_6.doc @ 6853 @ 6.2 24V DC Power Supply  The supply voltage is provided via a lead‐through terminal including a screw connection (Phoenix Contact  COMBICON MC 1,5/4‐STF3.81). (The figure shows the socket inside the device)    Pin‐Number  Signal‐Name  1  PE  2  0V DC    3  Ignition contact ...
  • Page 24 VMT6008   Note:  If the case is connected with earth potential at the provided PE contact (e.g. by connecting  the PE contact with the device plug), the electrical insulation is no longer given. This also  applies if the device is installed by using a metal retainer clip.  If you want to have the device electrically insulated from the power supply, you  have to use a method of installation that ensures appropriate insulation.   How to proceed if a PE system is used:  You  must  adhere  to  the  following  figure  in  order  to  ensure  a  correct  installation  of  the  PE  system.    Abb. 13:     © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 25: Autostart (S1)

    VMT6008 Zündungsfunktion (Ignition)  The device is capable of being externally started by using an additional signal input. This function is well known  from the automotive industry (switch‐on by using an ignition contact). The device is here continuously supplied  with a 24 V DC power supply, and only if the additional signal is present at the ignition contact, e.g. as a result of  turning the ignition key of the forklift, the computer is switched on or the blocking is released. This function  protects the system from unauthorised use, and saves energy by using the battery of the vehicle only in  connection with the vehicle being used, at the same time, if the device is installed onboard of vehicles or other  mobile and battery driven equipment. This function can be configured by using the Ignition Key Locking software  tool. It allows you, for instance, to shut down the computer after expiry of a timer once the voltage is no longer  present at the ignition contact.  Preassembled supply cables that allow the use of this ignition function are available from ads‐tec.    Note:  Switching the device ON or OFF by using the Power button will override the ignition  function. That means, if the device is switched off by using the Power button, the  system is shut down and can be restarted by using the Power switch after that, but  can then also be restarted by using the ON/OFF function of the ignition.     Warning:  The ignition signal works with a threshold value of 5V DC. The voltage must never exceed  the maximum voltage of 36 V DC! Risk of destruction!  Do not use the device onboard of vehicles with more than 24 V DC system voltage without  any voltage adaptation for the ignition contact! Risk of destruction!      Note:  The ignition function must never be used together with the autostart function, at  the same time!     Note:  The ignition function is available with most operating systems.   Pos: 27 /Datentechnik/Schnittstellen/Autostart/Autostart für VMT 60xx @ 1\mod_1246631044840_6.doc @ 5885 @ 6.3 Autostart (S1) ...
  • Page 26: Speakers

    VMT6008 6.4 Speakers  The VMT 60xx has two internal speakers.            Abb. 14:       Note:  The volume can be set up by using the device front keys. When activating the  described key combinations, the volume level is modified. If the soft keyboard is  installed, the system volume is additionally displayed by a display bar.     Abb. 15:   Pos: 29 /Datentechnik/Schnittstellen/USB-Anschluss/USB-Anschluss für VMT 60xx @ 2\mod_1260457598122_6.doc @ 6860 @ © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 27: Usb-Interface

    VMT6008 6.5 USB‐Interface   The USB interfaces are used for connecting peripherals with USB connection. These interfaces comply with the  USB 2.0 standard requirements.    Pin‐Number  Signal‐Name    1  VDC    2  D ‐  3  D +  4  GND        Note:  The device supports a maximum of 8 external USB mass storage devices. If a USB  Flash SSD is integrated, a maximum of 7 USB mass storage devices can be  connected.     Note:  The USB interfaces can be individually locked by using the "Lock USB" software  tool.   USB‐Interface in Front panel  One USB interface can be accessed from the front. The interface is located under a plastic cover underneath the  display. The cover has a tab on the right‐hand side, which is used for opening. The plastic cover of the USB  interface must be returned in protective position after use.  Pos: 30 /Datentechnik/Schnittstellen/PS2/Kombi Buchse für VMT 60xx @ 2\mod_1268840073235_6.doc @ 7482 @ 6.6 PS/2 Interface ...
  • Page 28: Netzwork Connection (Rj45)

    VMT6008     Note:  Since the timing of the integrated controller is specifically set up for cherry keyboards,  keyboards of this manufacturer should preferably be used.  If the soft keyboard is actively displayed on the monitor, the use of the external keyboard  for control purposes is limited.  The keyboard must be connected before switching the device on, because the  keyboard interface is initialised in the process of booting. If the keyboard is plugged  in while the device is running without having had the keyboard connected while  booting, it will not be functional.   Pos: 31 /Datentechnik/Schnittstellen/Netzwerkanschluss RJ45/Netzwerkanschluss RJ45 für VMT60xx @ 2\mod_1260451135970_6.doc @ 6856 @ 6.7 Netzwork Connection (RJ45)  If the drivers required for functioning are installed on the device, the control system may be integrated in an  Ethernet network supporting the 10/100/1000Mbit standard by using the Ethernet 10/100/1000BaseT network  connector. Specifications of this network topology must be observed in this case. You can install the drivers  required for functioning from the enclosed service CD, should they not be installed on the device.    Pin‐Number  Signal‐Name  1  TX +  2  TX ‐  3  RX + ...
  • Page 29: Optional Radio Network Card

    VMT6008 6.8 Optional Radio Network Card  The device is equipped with a Mini PCI Express WLAN card with two antennas integrated in the front panel.  The Mini PCI Express WLAN card supports the standards 802.11a/b/g.  802.11b/g:  11Mbit / 54Mbit, 2.4GHz  802.11a:  5 4MBit, 5GHz    Additionally, the following security standards are supported:  WEP 64 bit, 128 bit 802.11i  WPA TKIP, CCMP (AES)  WPA2 TKIP, CCMP (AES)  WPA PSK (preshared key)  WPA enterprise: EAP‐TLS    Specifications of this network topology must be observed in this case.    Note:  As an option, this device can be equipped with an internal antenna and an external  antenna connection (R‐SMA connector).  In this case, the optimum WLAN function is only be ensured if an external antenna  is connected.   Warning:  If an external antenna is used, which is not approved by ads‐tec, the operator/operating  company shall be responsible for compliance with the regulatory and legislatory  requirements.  Pos: 33 /Datentechnik/Schnittstellen/Serielle Schnittstelle COM RS232/Serielle Schnittstelle COM (RS232) für VMT 60xx @ 1\mod_1246373571514_6.doc @ 5876 @...
  • Page 30: Serial Com Interface (Rs232)

    VMT6008 6.9 Serial COM Interface (RS232)  Pos: 33 /Datentechnik/Schnittstellen/Serielle Schnittstelle COM RS232/Serielle Schnittstelle COM (RS232) für VMT 60xx @ 1\mod_1246373571514_6.doc @ 5876 @ The serial interface is used for digital data transmission. The RS232 interface can be connected by using a  commercially available 9‐pin SUB‐D cable.        Note:  Pin 9 of the serial interface connector can be used for additional switching of a 5V  power supply, e.g. for operating a serial barcode scanner. The COM +5V switch in  the service slot of the device must be put in the ON position in order to use this  function. A subsequent restart of the computer might be required in order to  properly activate this function..   Pin‐Number  Signal‐Name  1  DCD  2  RxD  3  TxD  4 ...
  • Page 31: 7  Drives

    VMT6008 7 Drives  The storage medium is selected according to the customer requirements. The following options are available for  storage:     Flash SSD:  A  Flash  SSD  with  a  storage  capacity  of  at  least  1GB  is  used.  Its  capacity  depends  on  the  desired  operating system and the additional programmes to be installed.      Note:  Recommendation for the choice of storage medium with a basic installation:  SSD Flash memory: Windows CE 6.0 / Windows XP embedded  Hard disk: Windows XP Professional Pos: 35 /Datentechnik/Laufwerke/Externe Laufwerke/Externe Laufwerke für OPC 5112 / 5115 / 5117 / IPC 1100 / CPC / PLC / OTC / ITC / VMT-Serie @ 0\mod_1158926656205_6.doc @ 563 @ Externe Laufwerke ...
  • Page 32: 8  Software-/Driver-Installation

    VMT6008 8 Software‐/Driver‐Installation   The device will be delivered with a pre‐installed Windows / Linux operating system depending on what the  customer wants. The drivers required for this are already installed and the operating system will be enabled by  entering the licence information. Should an initial installation be required, please follow the following steps. With  a newer operating system like Windows XP, the network card and graphics card will properly be recognised  during the initial installation, so that only the touch screen driver and the soft keyboard must be installed  separately.      Note:  If the hard drive was formatted, the operating system can be reinstalled by using one of  the existing interfaces.  An external keyboard is required for installation.   Installation of the Operating System    The device does not have any integrated CD drive. The installation of the operating system can therefore only be  carried out by using the USB interface.    Procedure for installation   The boot drive in the system Bios must be switched to USB in order to boot the  device from the USB interface.   Restart the device and insert a Windows CD.   Install Windows and set up the basic data.   With devices including touch screens, the touch screen driver as well as the soft  keyboard should be installed in order to ensure their full functionality.    With Windows CE 6.0 or Windows XP embedded, a complete image can also be installed by using a USB stick.  Pos: 37 /Datentechnik/Software / Treiber Installation/Touch Screen/Touch Screen Installation für OPC 5112/5212/5315/5515/5317/5319 / CPC5006/OTC5006/ VMT-Serie @ 0\mod_1159175108636_6.doc @ 665 @...
  • Page 33 VMT6008 TouchScreen Driver Installation       Note:  When installing the driver, you'll have to take in account that the touch screen monitor is  internally connected with the USB interface!  Touch screen monitor and PS2 mouse can be operated simultaneously.   The installation has to be carried out as described below:     Switch on PC and boot.   Access  the  service  CD  by  using  the  Explorer  and  start  the  Installer  file  in  the  TouchScreen folder.   Follow the on‐screen instructions and acknowledge the licence terms and conditions.   Once the installer has completed the installation, shut down the computer and restart  it subsequently.   After restarting, the touch screen monitor has to be calibrated. If the driver does not  automatically start, activate the setup menu via "Start => Settings => Control panel  => Elo Touchscreen".   Via the "Calibration data" menu, calibrating the touch screen monitor can be started, ...
  • Page 34: Configuration Center

    VMT6008 8.1 Configuration Center    Configuration  The start page of the Configuration Center provides you with an overview of which ads‐tec applications are  installed on the device. Additionally, you can start any of these applications from the Configuration Center by  double‐clicking on it      Information  In the Information section, device specific data like the device type, the firmware version and the serial number  are listed. The information you'll find here must be indicated whenever you need to contact the support  department.         © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 35: Automatic Brightness Adaption

    VMT6008 8.1.1 Automatic Brightness Adaption      Note:    The application of Automatic brightness adaptation allows the user to configure the  respective display brightness.   The display brightness can be changed manually, or alternatively automatically by enabling the Automatic  brightness adaptation, which controls the brightness automatically depending on the ambient light level. Once  the automatic brightness control is enabled, the brightness can no longer be modified by using the front keys.  We distinguish between two different control modes with the automatic control:    Day mode / Night mode  Separate display brightness levels can be programmed for either of both modes.      Note:    The threshold for Day‐/Night mode has to be determined individually by the user  for each device.   The day mode is enabled as soon as the ambient brightness is high enough. The display brightness should be set  to a slightly higher level than at night.  The night mode is enabled if the ambient brightness level is low. The display brightness can be set to a lower  level in this mode.  The operating mode of the automatic control can seamlessly be changed between day and night mode by using a  slide control.  The closer the slider is to the day mode position, the darker the ambient light must be before the display  brightness is changed to night mode. And vice versa: the closer the slider is put to the night mode position, the  brighter the ambient light must be before the display brightness is increased to the value set up for the day  mode.  In order to save the changes, you'll have to push either Save or OK.    © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 36: Com Input Configuration

    VMT6008 8.1.2 COM Input Configuration  COM input configuration allows the application to verify the correct RFID function. By activation of COM2,the  data is send  automatically to an active application that uses the COM2 port forwarded.      Note:    Unnecessary applications that use the COM2 port must be stopped before running  the COM input configuration. Because of different programming, data on various  editors like Notepad or Word are represented differently.     8.1.3 Ignition   The ignition application allows the control of the VMT6 device ignition function. If the status is set to Enabled,  the device is switched off after expiry of the preset period of time.        © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 37: Usb-Lock Function

    VMT6008 8.1.4 USB‐Lock Function  The USB lock function enables you to lock the USB ports, if required, and to avoid access by unauthorised people.  Feedback  In the Messaging section, you can set up whether a message should be output in the event that a USB port is  locked or not. Additionally, the locking process can be logged in the event log  Password Protection  In order to avoid any unauthorised access to the USB Lock programme, the settings made can be provided with  password protection.  In this case, the settings can only be modified if the password was entered correctly.  USB Ports  The desired USB ports can individually be locked by using the Lock button.      All changes must be confirmed with the Save button.        © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 38: On/Off Button Configuration

    VMT6008 8.1.5 On/Off Button Configuration   The ON / OFF pushbutton configuration allows to change the behaviour of the ON / OFF pushbutton.      Regular Mode  The ON / OFF pushbutton switched the device on and off      Secure Mode  The ON / OFF pushbutton only switches the device on. The switch‐off function is disabled        Note:    If the secure mode is used, the device can only be shut down by the software.     © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 39: Exemplary Rfid Application

    VMT6008 8.1.6 Exemplary RFID Application  The exemplary RFID application was developed in order to test the function of the RFID reader.          Note:    In the Interfaces section of the manual you can find more information about the  topic of RFIDs.   8.1.7 Softkeyboard  Here you can configure the soft keyboard application. A large variety of settings, like layout or commands can  individually be adapted.      All changes must be confirmed by pushing the Save button..    © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 40: Screen Mob

    VMT6008 8.1.8 Screen Mob  The Screen Mob application was developed in order to disable the touch screen of the device for a certain period  of time. This function can be used for cleaning the touch screen.    Pos: 38 /Datentechnik/Software / Treiber Installation/Softkeyboard/Softkeytastatur für alle Gerät ohne internes Laufwerk(CD/DVD) @ 0\mod_1159175310134_6.doc @ 667 @ 8.1.9 Softkeyboard   The soft keyboard must be installed from the enclosed service CD in order to ensure usability of the 5 keys  (except for the VMT series, where you have 6 keys) underneath the monitor. The installation has to be carried  out as described below:     Plug in connector of external drive at the device    Switch on PC, insert driver CD into drive after booting   Start installer from the service CD   Follow on‐screen instructions, install the driver, select the language and confirm the  restart of the computer.     ...
  • Page 41: 9  Technical Details

    VMT6008 9 Technical Details  Pos: 40 /Datentechnik/Service und Support/Service & Support @ 2\mod_1254312498746_6.doc @ 6472 @ Device Data  VMT6008  VMT6010  VMT6012  VMT6015  Housing  Powder coated aluminium diecast case  Front Panel  Fibreglass reinforced plastic, paint coated  Display  8" TFT  10,4" LED  12,1" TFT  15,1" TFT  Resolution  800 x 480 Pixel  1024 x 768 Pixel  800 x 600 Pixel max.  1024 x 768 Pixel   Displayable Colours  max. 16,1 Mio.   max. 16,1 Mio.  max. 256k Colours  max. 16,1 Mio.  Touch ...
  • Page 42: 10  Service & Support

    VMT6008 10  Service & Support  ads‐tec and its partner companies offer your customers a comprehensive service and support, which ensures  availability of a fast and competent support with respect to all upcoming questions related to ads‐tec products or  assemblies.    Since the devices manufactured by ads‐tec are also used by associate companies, these devices might be  configured in customer specific ways. Should any questions arise with respect to these specific configurations  and software installations, they can only be answered by the system manufacturer.   For devices not directly purchased from ads‐tec we don't deliver any support. The support is delivered by our  associate companies in these cases.    10.1  ads‐tec Support    The ads‐tec support team is available for phone calls from direct clients from Monday to Friday from   8:30 AM to 5:00 PM by using the following phone number:  Phone:    +49 711 45894‐500  Fax:    +49 711 45894‐990  Email:    mailbox@ads‐tec.de    10.2  Company adress    ads‐tec  Automation Daten‐ und Systemtechnik GmbH  Raiffeisenstraße 14  D‐70771 Leinfelden‐Echterdingen  Germany    Phone:    +49 711 45894‐0 ...
  • Page 43: 11  Declaration Of Ce-Conformity

    VMT6008 11 Declaration of CE‐Conformity  VMT6008    © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 44 VMT6008 VMT6010    Glossar © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 45 VMT6008 VMT6012      © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...
  • Page 46 VMT6008 VMT6015  Glossar   Glossar   © ads‐tec GmbH • Raiffeisenstr.14 • 70771 Leinfelden‐Echterdingen...