  • Page 1 ELECTRIC VEHICLE CHARGER EVC05 Series User Manual...
  • Page 2: Table Of Contents

    7 - ERROR and FAULT CONDITIONS.................22 7.1 - ERROR CONDITIONS.................22 7.2 - TRIPPING RELAY ON PRODUCTS WITH RESIDUAL CURRENT DEVICE CAUTION....................23 7.3 - DC 6mA LEAKAGE CURRENT SENSOR BEHAVIOR........23 IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 1...
  • Page 3: Safety Information

    This device is intended only for charging vehicles not requiring ventilation during charging. • To prevent risk of explosion and electric shock, ensure that the specified Circuit Breaker and RCD are connected to building grid. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 2...
  • Page 4: Important Safety Instructions

    The charging station has TYPE 2 AC outlets to be used for mode 3 charging. Also the charging station has optional schuko socket outlets to be used for mode 1 charging. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 3...
  • Page 5: Ground Connection Warnings

    Class II/C Type Surge Protector Device (SPD) • MCCB (Thermic Magnetic Adjustable) must be connected to the upstream distribution box. 25-35 EVC05-AC44 44 kW 80A Curve-C EVC05- 25-35 51,4 kW 100A Curve-C AC44*****S* IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 4...
  • Page 6: Description

    Blank : Case-B Connection with normal socket : Case-B Connection with shuttered socket : Case-B Connection with LID socket : Case-B Connection with Type-2 socket Cabinet EVC05 IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 5...
  • Page 7: Electrical Specification

    Daisy Chain Wi-Fi 802.11 a/b/g/n Mobile Connectivity (Optional) LTE / 3G / 2G PLC HLC (Optional) ISO 15118 RFID Reader ISO 14443A/B and ISO 15693 w/SAM Module IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 6...
  • Page 8: Other Features (Connected Models)

    Weight (with packing) 95 kg ENVIRONMENTAL SPECIFICATIONS Operation Condition Temperature -25 °C to + 50 °C Humidity 5 % - 95 % (Relative humidity, non-condensing) Altitude 0-3.000m IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 7...
  • Page 9: General Information

    1 - INTRODUCTION OF THE PRODUCT COMPONENTS Display ALS Sensor RFID Card Reader Notification LED Door Lock Mechanism AC Type-2 Socket Outlet MID Display Window Branding Area IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 8...
  • Page 10: Plug Charging Cable To Each Socket

    RFID Card to the reader which is under the screen. Then the charging will be started. Details are explained in Charging Scenarios section. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 9...
  • Page 11: Schuko Socket Outlet (Optional)

    Close the schuko metal cover down and be sure that the schuko cover is closed properly. The charging cable should be passed from the hole under the cover as shown in the figure below. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 10...
  • Page 12: Charging Scenarios

    RFID card to the reader. After the schuko cover unlocks, then lift up the cover and you may be able to connect your plug to the schuko socket. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 11...
  • Page 13: Ac 22 Kw Socket Outlet

    3.1.1 - VEHICLE CONNECTION & CHARGING Connect charging cable to the available socket and select that socket from the touchscre- Tap your RFID card or scan QR Code to start charging. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 12...
  • Page 14 It may take a few seconds for charging session to start. Charging state can be seen in charging page While charging, charging state can be seen in the main menu. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 13...
  • Page 15: Stop Charging

    3.1.2 -STOP CHARGING Click “Stop Charging” to end the charging session. Tap your RFID card or scan QR Code to stop charging. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 14...
  • Page 16 Disconnect the charging cable. After disconnection, you will automatically move to the main screen. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 15...
  • Page 17: Schuko Socket Outlet (Optional)

    3.2.1 - VEHICLE CONNECTION & CHARGING Connect charging cable to the available socket and select that socket from the touchscre- Tap your RFID card or scan QR Code to start charging. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 16...
  • Page 18 It may take a few seconds for charging session to start. Charging state can be seen in charging page IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 17...
  • Page 19: Stop Charging

    While charging, charging state can be seen in the main menu. 3.1.2 -STOP CHARGING Click “Stop Charging” to end the charging session. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 18...
  • Page 20 After disconnection, you will automatically move to the main screen. Please be sure that the schuko cover is closed properly for the next charging section’s availi- bility. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 19...
  • Page 21: Circuit Breaker And Other Critical Component Locations

    Blinks Red twice; 500 ms ON 500 ms User rfid card removed from list 4 sec Blinks Red three times; 500 ms ON 500 Unregistered rfid card tapped ms OFF 4 sec IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 20...
  • Page 22: Rccb Reclosure Unit Behaviour (Optional)

    RCCB disconnections because of temporary EV behaviours. The yellow switch in RCCB Reclosure Unit should be at “ON” position to use this functionality. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 21...
  • Page 23: Error And Fault Conditions

    Turn on MCB and/or RCCB. (See section “CIRCUIT AC 22kW output unavailable. RCCB and/or MCB is tripped BREAKER LOCATIONS FOR CHARGING OUTPUTS“) Check functionality for the station. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 22...
  • Page 24: Tripping Relay On Products With Residual Current Device Caution

    6mA. If the charging station goes to error state due to DC leakage current, charg- ing cable must be unplugged from vehicle and then from the charging station to reset this error. IB v3.0.0 2021 © 2021 ZES - All rights reserved English - 23...
  • Page 25 Manufacturer Name: Vestel Electronics Address: Vestel Elektronik Sanayi ve Ticaret A.S. Organize Sanayi Bölgesi 45030 Manisa - Turkey...

This manual is also suitable for:

Evc05-ac44

Table of Contents