MCT-220
Wireless Emergency Button
1. INTRODUCTION
1.1 General
The MCT-220 enables people, for example senior citizens in their
home environment, to transmit an emergency call when they are at
some distance from their communication unit.
1.2 Additional Features
Can be used for panic alarm, when used with a Visonic Amber or
PowerMax family system.
Can be used for X-10 devices activating when used with a Visonic
PowerMax family system.
An auxiliary sensor can be connected to the MCT-220. When the
sensor is in an alarm state, the MCT-220 sends an alarm message
from its auxiliary channel.
Enables people to answer incoming calls when the telephone is out
of reach, when used with a Visonic Amber family system.
MCT-220 button pressing period - 2 seconds or 300 milliseconds
(selectable by an internal function selector).
2. SPECIFICATIONS
GENERAL
Compatibility: Compatible with all Visonic control panels and
receivers.
Operating Frequencies (MHz): 315, 433.92, 868.95, 869.2125 or
869.
Maximum Tx Power: 10dBm @ 433MHz, 14dBm @ 868MHz.
ELECTRICAL
Internal Battery: 3V battery type CR123
Current Consumption: 35 mA (during transmission), 20µA in
standby mode.
Battery Life Expectancy: 5 years (for one alarm per day)
ENVIRONMENTAL
Operating Temperature: 0° to 50°C (32° to 122°F)
Standards: Designed to comply with FCC CFR 47 Part 15, RSS-210.
PHYSICAL
Dimensions (Diameter x H): 90 x 35 mm (3-1/2 x 1-3/8 in)
3. PREPARATION FOR USE
3.1 Cover Removal
COVER
1
Figure 2 – Cover Removal
3.2 Function Selector Setting
The MCT-220 has a 4 lever switch (see Fig. 3). Each switch lever
allows you to select one of two options.
FUNCTION SELECTOR
MOUNTING HOLE
WIRING KNOCKOUT
Figure 3 – Internal View
Set the switches as desired (see table 1)
prior to applying power. Use a ball point pen
or another pointed object to shift the switch
levers. The ON position is indicated on
the switch body.
D-301850 MCT 220 User's Guide
BASE
2
BATTERY
MOUNTING HOLE
AUXILIARY INPUT TERMINALS
ON
1
2
3
Figure 4
Function Selector
Supervision signal is regularly transmitted to the communication
unit.
In low battery voltage state, an alarm message is sent to the
communication unit and the MCT-220 button blinks during
transmission.
Push button back light can be switched On/Off by an internal
function selector.
Auxiliary input E.O.L / Normally Close type can be selected by an
internal function selector.
Auxiliary input alarm restore message can be enabled / disabled
(selected by an internal function selector).
Water resistant.
Weight: 110g (3.9 oz.) Color: White
Note: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user's authority to operate the
equipment.
Compliance with standards (Europe): ETSI EN 301 489-3, EN
50130-4, EN 300 220-2, EN 300 220-1, EN 60950-1
This device complies with Part 15 of the FCC Rules and RSS-210 of
Industry and Science Canada. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Hereby, Visonic Ltd. declares that the radio equipment type MCT-220
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address: http://www.visonic.com/download-center
Table 1. Function Selector Description
Function
SW1
Back light ON/OFF
SW2
Aux. input type
selector (*)
SW3
Auxiliary input
restore reports
enable/disable (**)
SW4
Pressing period of
push button
(*) SWITCH SW2 determines whether the auxiliary input will behave
as a 47k end-of-line (E.O.L.) input or as a normally closed
(N.C.) input.
(**) SWITCH SW3 determines whether the MCT-220 will report a restore
event when the auxiliary input restores from an alarm condition.
3.3 Battery Insertion
Insert battery (see Figure 3) – Verify proper polarity.
Caution! Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries
instructions.
4
User Guide
Figure 1 – MCT-220
Pos.
Selected Option
ON
Button's back light ON
OFF Button's back light OFF
ON
Aux. input is E.O.L. (47 k)
OFF Aux. input is N.C.
ON
Aux input Restore events
are reported
OFF Aux. input restore events
are not reported
ON
2 seconds
OFF 300 milliseconds
according to the manufacturer's
Default
ON
OFF
ON
OFF
1
Need help?
Do you have a question about the MCT-220 and is the answer not in the manual?