HQ RC UNI/AIRCO3 - Remote Control Manual

HQ RC UNI/AIRCO3 - Remote Control Manual

Advertisement

HQ RC UNI/AIRCO3 - Remote Control Manual

Panel description

Panel description

  1. Run mode display
  2. Signal sending display
  3. Blowing direction display
  4. Model code
  5. Temperature "-" key
  6. Mode key
  7. Automatic blowing direction control key
  8. Power key
  9. Fast cool key
  10. Timing off key
  11. Enter key
  12. Clock function key
  13. SET
  14. Timing on key
  15. Fast heat key
  16. Fan key
  17. Blowing direction control key
  18. Temperature "+" key
  19. Fan display
  20. Temperature display

Installing the batteries

Remove the battery cover of the remote control and install two AA size batteries.

Install the battery cover. The time will appear in the left corner of the LCD display.

Set up instructions

Method A: digital automatic search set up.

  1. Turn on air conditioner and aim the remote control directly at it
  2. Hold the "SET" button until the code changes in the mode window. Then release it. The system will switch to automatic search and the code will increase with 1 unit every two seconds. Pay attention to the air conditioner. Keep searching until the air conditioner automatically turns on/off. Press the 'ENTRY'key to finish set up.

Method B: direct code setup.

  1. Refer to the CODE FORM and find the number corresponding with your brand.
    Power on the air conditioner by hand. For example: INYCIN is code 188-190.
  2. Hold the "SET" button( for about 3 seconds) until the code flashes in the display.
    Press temperature "+" or "-" until the code you want to choose is shown.
  3. Press "ENTER" and the code stops flashing.
  4. Check whether the keys on the remote control work normally. If not, repeat steps b-d until a suitable code is found.

Timing on/off function

Press "Timing on" key to increase the starting time for the air conditioner by 1 hour. The displayed time is the time when the air conditioner will automatically be switched on. Pressing "Timing off" key will delay the time the air conditioner will be turned off by 1 hour each time the key is pressed. The timing function uses a 15 h indication to show and set up the time.

Fast cool/Fast heat function

Press the "Fast cool" key to automatically set the air conditioner to 21 degrees C, middle wind, automatic blowing direction. Or, press the "Fast heat" key to automatically set the air conditioner to 27 degrees C, middle wind and automatic blowing direction.

Notes

Make sure the air conditioner is in working order. Be aware that the remote control cannot increase the function of the air conditioner. If the remote control will not be used for a long time, make sure to remove the batteries to prevent damage to the remote control.

Safety precautions:
shock hazardTo reduce risk of electric shock, this product should ONLY be opened by an authorized technician if service is required. Disconnect the product from mains and other equipment if a problem should occur.

Warranty:
No guarantee or liability can be accepted for any changes and modifications of the product or damage caused due to incorrect use of this product.

General:
Designs and specifications are subject to change without notice.

Applicable brand and code list

BRAND CODE BRAND CODE
AKIRA 796-797 GALANZ 140-149
AUX 180-199 GREE 000,020-039
AUCMA 210-229 GEER 342-343
AIDELONG 293-295 GLEE 280
AITE 296-299 GUQIAO 344
AOLI 300 GUANGDA 345-346
AOKE 301-302 HAIER 001-019
BAIXUE 299 HICON 391-392
BEIJINGJINGDIAN 304 HITACHI 640-659
BOERKA 305-306 HISENSE 230-239
BORLER 307 HONGYI 347
BOSHIGAO 308-309 HUABAO 100-109
BOSHI 310 HUALING 150-169
BIG-THUMB 331 HUAGAO 348
CAIXING 311 HUAWEI 281
CARRIER 690-699 HUAKE 349-350
CHANGLING 312-323 HUAMEI 351-352
CHANGHONG 060-079 HUANGHE 353
CHANGFENG 190 HUIFENG 354-356
CHENGYUAN 324 HUIFENG 357
CHUANGHUA 325-328 HYUNDAI 780-789
CHUNLAN 170-179 INYCIN 475-483
CHIGO 080-099 JIALE 358
CONROWA 337-341 JIANGNAN 359
CORONA 760-769 JMSTAR 360
CHANGFU 835-838 JINBEIJING 361-362
DAEWOO 332-333 JINDA 491-492
DAIKIN 740-759 JINSONG 363-365
DAJINXING 329,330 JOHNSO 282
DAOTIAN 821-824 KANGLI 368-370
DONGXINBAO 260-268 KELONG 110-119
DONGXIA 334-335 KLIMATAIR 797-800
DUNAN 336 KONKA 366-367
ELECTROLUX 471-474 KRIS 804-805
FEILU 240-249 KT02_D001 283
FEIGE 829-830 KT02_D002 284
FRESTECH 270-279 KTY001 285
FUJITSU 700-719 KTY002 286
GOLDSTAR 303 KTY003 287
KTY004 288 SHUANGLU 416-418
KTY005 289 SIGMA 447
LIANGYU 780 SOGO 291
LG 600-609 SOVA 292
LITTLESWAN 453 SONGXING 419
LIKEAIR 386-387 SOVA 420
LOREN-SEBO 801-803 SOYEA 421-422
MCQUAY 790-795 SRTC 423
MD 040-059 SUNBURG 817-820
MEILING 389-390 TCL 120-139
MINGXING,BOYIN 290 TECO 831-834
MITSUBISHI 551-599 TIANYUAN 425-428
NATIONAL 660-690 TIANJINKONGTIAO 424
NISO 497 TOBO 250-269
NISO 398-399 TONGLI 429-430
NIKKO 810-811 TOSHIBA 630-639
PANSONIC 660-689 TOYO 825-828
PANDA 464-466 TRANE 812-816
PINSHANG,XINHUABAO 290 UNI-AIR 368-369
QIXING 393 UTTLEDUCK 454-456
RAYBO 371-383 WANBAO 431-433
ROWA 383-385 WEILI 434-443
RICAI 394 WEITELI 444
RIJIANG 395-397 WHIRLPOOL 770-774
SACON 414 WUFENG 445-446
SANZUAN 190 XILENG 448-449
SANYO NEC 500-550 XINLE 457-460
SAMSUNG 610-629 XINLING 461
SAST 450-452 XINGHE 462-463
SERENE 499 YAIR 467-471
SHARP 720-739 YAOMA 470
SHAMEI 400 YIDONG 499
SHANXING 401-402 YORK 775-779
SHANGLING 403-409 YUTU 484-490
SHENBAO 410-411 ZHONGYI 493-494
SHENGFENG 412 ZUODAN 495
SHENGFENG\FEILU 413 OTHER

496,498

806-809

839-999

SHINING 415
SHINCO 200-209

This company reserves the right to interpretation of the User's Manual.

Design and technical parameters may vary without notice.

Documents / Resources

Download manual

Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.

Download HQ RC UNI/AIRCO3 - Remote Control Manual

Advertisement

Need help?

Need help?

Do you have a question about the RC UNI/AIRCO3 and is the answer not in the manual?

Questions and answers

Table of Contents