APX 5.0-30.0P-S2 High Voltage Battery System Growatt New Energy Download Manual User Manual Shenzhen Growatt New Energy Co., Ltd 4-13/F, Building A, Sino-German (Europe) Industrial Park, Hangcheng Ave, Bao’an District, Shenzhen, China +86 755 2747 1942 service@ginverter.com www.ginverter.com GR-UM-285-A-00...
Table of Contents About this Document This document introduces the APX 5.0-30.0P-S2 Battery System (short for APX) in terms of installation, electrical connection, operation, commission, maintenance, and 1 Product Overview troubleshooting. Before installing and operating the APX system, ensure that you are 1.1 Intended Use...
1 Product Overview 1.1 Intended Use Port Function The entire APX 5.0-30.0P-S2 high-voltage energy storage system is composed of a APX 98034-P2 (hereinafter referred to as Power Module) and multiple APX 5.0P-B1 battery Turn on/off the power connection from Power DC switch...
Page 4
LED display 1.2.2 APX 5.0P-B1 (Battery Module) Battery Module consists of LFP battery cells, a DC-DC converter, mechanical parts, the battery management unit (BMU) as well as power and communication terminals. Product appearance is shown as below. Figure1- 3: LED display Function Function description Display SOC...
Ÿ Unauthorized modifications or removal of the software package. Ÿ The APX 5.0-30.0P-S2 high voltage battery system is composed of a Power Module APX The product's tamper evident label is removed or any item is missing due to customer's Ÿ...
Ensure that the positive and negative terminals are correctly Weight:50kg connected Operation Ambient Temperature:-10°C-+50°C Keep away from open flame or ignition sources Shenzhen Growatt New Energy Co.,Ltd. Made in China Bao'an District, Shenzhen, Guangdong P.P. China Observe the manual Figure 2-1: Nameplate...
If the battery system is soaked or submerged in water, do not touch Flood emergency the batteries to avoid electric shock. Contact Growatt or your distributor immediately for technical assistance. The shell damage requires extra attention as it is of high risk. Do not Shell damage use batteries with a damaged shell, which may cause safety hazards.
4 Installation Ø Read through the Guidance before installation to understand product information and safety precautions; Wall Only qualified and well-trained technicians who fully understand the Ø whole photovoltaic system, grid network, battery system, working principle and national/local standards are allowed to perform operations on the battery;...
4.2 Installation Tools Standard Wall-Mounted Standard Floor-mounted Battery Matching inverter Prepare the following tools to install the battery system: Installation Compound Installation Compound capacity model Mode Mode 5kWh A+B+C A+B+E 10kWh A+B*2+C A+B*2+E M6-2N·m M4-1N·m 15kWh A+B*3+C A+B*3+E MOD 3-10K TL3-XH Screw Driver Drill Socket Wrench...
Page 10
4.3.1.3 Check the components of the APX 5.0P-B1 to Battery Module Parallel cable *1 APX 5.0P-B1(BM) install the wall bracket Figure 4-8: Install the mounting bracket Step 1: Install the mounting bracket. Anti tipping plate *2 M6 expansion bolt *2 M4x9 stainless steel screw *3 Trim-cover * 2 Dia 8.0mm...
Page 11
Step 3: Fix the wall bracket on the wall and place the first battery module on the mounting bracket. Install the anti-tipping plates on both sides and tighten the two screws. Mark the hole positions for installing the first battery module. Secure the module on both sides...
Page 12
Install the connecting pieces on both sides Marker and tighten the two screws. Secure the module on both sides to Level the wall. Loosen two screw, move up handle on both sides. Install the connecting pieces on both Keep the Battery Module level. sides and tighten the two screws.
4.4 Electrical Connection MID 11-30KTL3-XH Do not forget to wear ESD wrist strap and gloves, safety gloves and goggles. WARNING MID11-30KTL3-XH 4.4.1 Communication port definition Connector APX 5.0-30.0P-S2 MOD 3-10KTL3-XH MID 11-30KTL3-XH Terminal Terminal Terminal serial Silk screen serial Definition...
Page 14
4.4.2 System connection MID 11-30KTL3-XH MID 11-30KTL3-XH MID 11-30KTL3-XH A breaker has been installed in the Power Module. Therefore, a DC Ø circuit breaker is not recommended to be installed between the battery system and the hybrid inverter system. If you have installed a DC circuit breaker, do not perform operations on the DC circuit breaker with power-on, otherwise the machine may be damaged.
Page 16
B. APX 5.0P-B1 (Battery module) wiring Note: The battery is not allowed to be installed when the machine is running. Ensure that all the lights indicating “RUN” of battery modules are off before installation. Ensure that the PE cable is securely connected. 4.4.2.3 Electrical wiring connection A.
Power on/off the APX Battery 5 4.4.2.4 External Electrical Connections of the APX system Step 1: Cut the cable hole according to the wiring mode. Step 2: Cover it with a protective rubber ring, and route external cables through the cable hole.
The APX battery system will automatically shut down in a few minutes after the LED indicator and the logo “Growatt” go off. Do not turn on the switch Notice until it is completely powered off.
6 Maintenance Guide 6.1 Preparation The Battery Module contains batteries. Dispose of them in Ø After the system is powered off, the remaining electricity and heat still exist in the compliance with local laws and regulations. chassis, which may cause electric shocks or burns. Therefore, you need to wear Notice protective gloves and perform operations 10 minutes after the system is powered off.
6.5 Troubleshooting Indicator Description Cause Measures Indicator Description Cause Measures The power Check whether the power cable cable is Power cable between the Power Module and disconnected to 1.There is no safety risk. disconnected the Battery Module is securely the Power 2.Ensure that the inverter is connected.
Items Specifications Module APX 5.0P-B1 Nominal Capacity/Energy 100Ah/5kWh Rated/Usable Capacity/Energy 100Ah/4.5kWh Shenzhen Growatt New Energy Co., Ltd Rated Voltage 385V 4-13/F, Building A, Sino-German (Europe) Industrial Park, Hangcheng Ave, Bao’an District, Shenzhen, China Operating Voltage 330-450V +86 755 2747 1942 Rated current (25℃)