Power source
Power consumption
CONTENTS
AC110V, 220-240V / 50-60Hz
(Separately available)
II..........
110V,230V 1000W
220V 930W
240V 1100W
I..........
110V 500W
220V 450W
230V 500W
240V 550W
Page
EH5235-A3
Air volume
Air flow temperature
(in case of room temperature 30°C)
Cord length
Weight
2
2
4
© 2003 Matsushita Electric Works, (Thailand) Ltd. All
rights
distribution is a violation of law.
ORDER NO.PCD0301A81C3
Hair Dryer
3
0.8 m
/min (II)
110V...105°C (II)
220 - 240V...105°C (II)
1.75 m
390 g
reserved.
Unauthorized
Page
6
7
8
copying
and

Advertisement

Table of Contents
loading

Summary of Contents for National EH5235-A3

  • Page 1: Table Of Contents

    ORDER NO.PCD0301A81C3 Hair Dryer EH5235-A3 SPECIFICATIONS Power source AC110V, 220-240V / 50-60Hz Air volume 0.8 m /min (II) (Separately available) Air flow temperature 110V...105°C (II) 220 - 240V...105°C (II) Power consumption II..110V,230V 1000W (in case of room temperature 30°C)
  • Page 2: Schematic Diagram

    EH5235-A3 1 SCHEMATIC DIAGRAM SW1 Main switch(ARG-1213-01-003) 110V(TAIWAN) 220V(KOREA) 220-240V CAPACITOR 0.1 µF, 275V NOT USE CAPACITOR (FOR MOTOR) 0.1 µF, 50VDC DIODE 5A, 600V D2×4 DIODE (BRIDGE) 2A, 400V TEMPERATURE FUSE 192°C, 10A, 250V MOTOR 15VDC, 1.37A MAIN SWITCH AC 125V,13A / 250V,6.5A...
  • Page 3 EH5235-A3...
  • Page 4: Assembly Instructions

    EH5235-A3 3 ASSEMBLY INSTRUCTIONS CAUTION : When soldering lead wires on switch, location and orientation of lead wires must be as shown in Figure 1. Figure 1 (1) Solder yellow and white lead wires into the heater as shown in Figure 2.
  • Page 5 EH5235-A3 (8) Set the air outlet grill and the outlet ring to the heater block by align ribs of the air outlet ring with slot of front housing as shown in Figure 6. Figure 6 (9) Assemble the air inlet grill into back housing with aligning mark of air inlet grill and mark of back housingas shown in Figure 7.
  • Page 6: Disassembly Instructions

    EH5235-A3 4 DISASSEMBLY INSTRUCTIONS (1) Remove 2 torque screws from the main body with a torque head driver as shown in Figure 8. Figure 8 (2) Remove hooks of front housing from back housing by rotating front housing clockwise direction as shown in Figure 9.
  • Page 7: Troubleshooting Guide

    EH5235-A3 5 TROUBLESHOOTING GUIDE NOTE: Refer to WIRING CONNECTION DIAGRAM. <TROUBLE> <CHECK> <REMEDY> → Check continuity of the power cord. → Replace the power cord. Hot air is not emitted at "II" or "I" position. ↓ OK → Replace the main switch.
  • Page 8: Exploded View & Replacement Parts List

    EH5235-A3 6 EXPLODED VIEW & REPLACEMENT PARTS LIST 6.1. EXPLODED VIEW 6.2. REPLACEMENT PARTS LIST Note : All parts are supplied from MEW-Thailand through PLGA. Remarks : *1= Available individually Ref. No. Parts No. Parts Name & Descriptions Remarks Per Unit...