Compliance with the Installation Instructions is a prerequisite for the applicability of the Limited Warranty provid ed by DAS Energy. Non-compliance with the present Installation Instructions and the subsequent damage might therefore revoke the Limited Warranty provided by DAS Energy.
PRODUCT TYPE DESIGNATION AND APPLICABLE PRODUCTS The DAS Energy PV modules are designated according to the respective number of cells and the position of the junction box: ... x ... M ...
Any mod- without notice. ifications or any use of DAS Energy products contrary to their specifications and not expressly authorized by DAS Energy will result in a loss of any liability claims. General information...
HANDLING OF THE MODULES The correct handling of DAS Energy modules is essential for the durability of the product. Therefore, the most im- portant notes on proper handling of the modules are listed below.
Work only under dry conditions and use only dry tools with insulated grips. Do not handle PV mod- be lethal! DAS Energy will not be held responsible in any way for accidents and damage to persons, ules when they are wet unless wearing appropri- including electric shock, caused by incorrect use or ate protective equipment.
The limit operating temperature should be within -40 °C to 85 °C. DAS Energy is not liable for any damage to persons, to the substrate/roof, the PV system (includ- Disclaimer: ing the PV modules as well as the cabling and cable trays) or any other object affected by the installation of...
MODULE LAYOUT The module layout should be planned by a qual- of at least 30 mm must be maintained. A larger dis- ified professional. Hereby all local and regional re- tance every two modules (in longitudinal direction) quirements and provisions must be observed. Fig. 1 creates a maintenance aisle and enables proper and Fig.
V. ELECTRICAL INSTALLATION A photovoltaic module behaves under solar irradiation like a direct-current generator (e.g. like a battery) and therefore has a positive and a negative contact. Depending on the irradiance hazardous voltages may occur! SYSTEM COMPONENT DIMENSIONING The rated electrical characteristics such as ISC, VOC ex pected operating temperature at the location of the and PMPP are measured within 3 % of measurement installation and the temperature coefficient for VOC.
(Source: Application Specification 114-137167: Solarlok PV BAR Junction Box Assemblies, 21 November 2018 Rev. D, TE Connectivity) Disclaimer: DAS Energy is not liable for any damage to the cables or the modules, in particular the junction box, arising from inadmissible cable bending, improper cable routing or inadmissible handling during installation (please obey national regulations!).
DAS Energy disclaims all liability and does not cover damages (and consequential damages) in the event of: Assembly, installation or use of the product not in accordance with DAS Energy’s instructions and specification (documentation, operating or assembly instructions, special recommendations, etc.) or industry standards;...
Page 13
In that case, DAS Energy must guidelines and instructions of the connector manufac- always be consulted in advance. Only after verification turer.
Page 14
Energy PV module under exclusion of the connector installation of the alternative connector. which has been replaced. DAS Energy is not liable for CONNECTORS MATING It is only allowed to connect a plus (+) coded connector to Connecting connectors of different polarity is done by a minus (-) coded connector.
PROTECTIVE GROUNDING The DAS Energy modules correspond to safety class II and do not have any accessible conductive parts or frames and do not need to be grounded. FUNCTIONAL GROUNDING / POTENTIAL INDUCED DEGRADATION (PID)
The electrical connectors may never be disconnected under load. Non-compliance can be highly dangerous! Disclaimer: DAS Energy is not liable for any damage to the substrate, on which the modules are bonded on, or the modules themselves resulting from the dismantling of certain modules. DISCONNECTING THE MC4-Evo2 COUPLER CONNECTION Disconnect the MC4-Evo2 coupler connections of the PV module which should be dismantled or rather replaced with the connected, adjacent PV modules according to V.
Page 17
MECHANICAL DISMANTLING In case the module is supposed to be installed and op- Modules, which are mounted via bonding can be disman- erated again after dismantling, please pay attention tled by means of a cutting wire with which the adhe sive not to sharply bend or apply focused pressure on the beads (as well as possibly available fixation tape) can module during the dismantling.
In Tab. 2 the potential sources of faults are listed, which may arise out of improper handling during the installa- tion or operation of DAS Energy modules, as well as instructions to avoiding these errors. POTENTIAL SOURCES OF FAULTS (TABLE 2)
FIRE SAFETY CLASS The DAS Energy PV modules are tested and certified for fire safety class C according to IEC 61730-2 and BROOF(t1) according to EN 13501-5. The fire rating of this PV modules is valid only when mounted in the manner specified in the mechanical mounting instructions (refer to IV.
Page 20
COMPOSITE SUPERLIGHT MODULE 11 x 6 € € ULTRA-LIGHTWEIGHT HIGH YIELD IN ANY POSITION Only 3.3 kg/m Multi-directional lens structure € € € € HIGH-EFFICIENCY SILICON CELL BENDABLE Monocrystalline cells Smallest bending diameter (2 m) No thin film! € € EASY TO INSTALL €...
Page 21
12 x 1 M 12 x 2 M COMPOSITE 60 Wp 120 Wp 2035 mm SUPER LIGHT 8.22 Voc 16.43 Voc 6.78 Vmp 13.56 Vmp MODUL 11 x 1 M 11 x 2 M 11 x 3 M 11 x 4 M 11 x 5 M 11 x 6 M 55Wp...