Read this operation manual carefully before use to ensure proper operation of this product.
Failure to read this operation manual may cause improper operation and may result in serious injury or death of a person.
The meanings of the symbols are as follows.
Failure to follow the instructions that accompany this indication and improper handling
WARNING
may result in serious injury or death.
Failure to follow the instructions that accompany this indication and improper handling
CAUTION
may result in injury and/or damage to property.
NOTE
Pay special attention to sections with this symbol.
It is required to check the operation manual if this symbol is shown on the product.
EN 16005
Setting to meet the requirements by EN 16005.
NOTE
1. This sensor is a non-contact switch intended for door mounting and to use on automatic swing doors.
2. When setting the sensor's detection area, make sure that there is no traffic around the installation site.
3. Before turning the power ON, check the wiring to prevent damage or malfunction of equipment
connected to the sensor.
4. Only use the sensor as specified in the operation manual provided.
5. Be sure to install and adjust the sensor in accordance with the local laws and standards of the country
in which the sensor is installed.
6. Before leaving the installation site make sure that the sensor is operating properly and instruct the
building owner/operator on proper operation of the door and the sensor.
7. The sensor settings can only be changed by an installer or service engineer. When changed, the
changed settings and the date shall be registered in the maintenance logbook accompanying the door.
The following conditions are not suitable for sensor installation.
Fog,
Exhaust
Wet
Grating
Objects
Specifications
Model
: OA-EDGE T
Profile color
: Silver/Black
Mounting height
: 1.5 (4'11") to 3.0 m (9'10")
: See Detection area
Detection area
Detection method
: Triangulation
Min. configuration
: 1 main module +1 LED module
Max. configuration
: 4 sensor modules +2 LED modules
Depth angle adjustment
: 0° to +25°
Power supply (*1)
: 12 to 24 VAC ±10 % (50/60 Hz)
12 to 30 VDC ±10 %
Power consumption
: < 1.3 W
(< 2 VA at AC) at Min. configuration
< 3.5 W
(< 4.5 VA at AC) at Max. configuration
LED indicator
: See LED indicator below
NOTE
The specifications herein are subject to change without prior notice due to improvements.
*1 : The sensor has to be connected to a door system is equipped with a SELV circuit.
The overcurrent protection of power supply cable has to be less than 2A.
*2 : According to EN ISO13849-1:2015
EN 16005
Install the sensor at 1.8 m (5'11") to 3.0 m (9'10").
LED indicator
Status
Sensor module indicator
Stand-by
Green
Red
Opening side detection (output 1)
Orange
Closing side detection (output 2)
Incomplete Initialization
Red & Green blinking
Yellow blinking
Learning
Incomplete learning
Yellow & Red blinking
Slow Red blinking
Signal saturation
Sensor failure
Fast Red blinking
Communication error
Twice Orange blinking
Dimensions and part names
X =Minimum 340 mm (13 3/8")
(4)
(5)
(3)
(1)
(6)
(2)
Sensor module
Main module
Tx
(9)
(8)
(7)
Secondary module
Tx
(9)
(8)
Original instructions
NI-0077-5
5916339 SEP 2022
WARNING
Danger of electric shock
Do not wash, disassemble,
rebuild or repair the sensor,
otherwise it may cause electric
shock or breakdown of the
equipment.
Reflection
Output hold time
: Approx. 500 ms
Response time
: < 75 ms
Operating temperature
: -20 to +55°C (-4 to 131°F)
Operating humidity
: < 80 %
Noise level
: < 70 dBA
Test input
: Opto coupler 10 to 30 VDC
Current 6 mA Max.
Safety/Test output 1
: Form C relay
Safety/Test output 2
Voltage 42 VDC
Current 0.3 A Max
(Resistance load)
Output : See Installation 3
IP rate
: IP54
Category (*2)
: 2 (EN ISO13849-1:2015)
Performance level (*2)
: d (EN ISO13849-1:2015)
ESPE
: Type 2
LED module indicator
The color depends on
the state of the output.
Safety/Test output 1
OFF
Green
ON
Red
Safety/Test output 2
OFF
Green
ON Orange
50.7 (2")
(1)
Profile
(2)
Front cover
(3)
Mounting clip
(4)
LED module
(5)
Spacer
(6)
Endcap
(7)
Power supply connector
(8)
Communication connector
(6)
(9)
LED indicator
(10)
Dipswitch A
(11)
Dipswitch B
(12)
Function switch
(3)
(13)
Angle adjustment screw
(7)
ON
ON
(10)
(11)
(12) (8)
(13)
ON
(11)
(8)
(13)
Complied standards and extract from EC declaration of conformity
ENGLISH
EN 16005:2012/AC:2015 Chapter 4.6.8 and Annex C
EN 61496-3:2001 clause 4. 3. 5 and 5. 4. 7. 3
DIN 18650-1:2010 Chapter 5.7.4 ESPE
Machinery Directive 2006/42/EC
Notified Body 0044 : TÜV NORD CERT GmbH Am TÜV 1, 45307 Essen Germany
For technical document, see European Subsidiary
Detection area
Detection area at 2200 mm (7' 2 5/8") : Depth 140 (5 1/2") x Width 870 (2'10")
Test conditions according to EN 16005
Emitting area at 2200 mm (7' 2 5/8") : Depth 140 (5 1/2") X Width 440 (1' 5 1/2")
NOTE
The actual detection area may become smaller depending on the ambient light, the color/material of the
object or the floor as well as the entry speed of the object.
Recommended installation position
d2
Leading
edge
h
d1
EN 16005 CA reference body
NOTE
Decrease the area depth angle, increase the non detection zone or move the sensor module
(see d2 in the chart) away from the leading edge to optimize the sensor performance.
For instaltion heigth <1900 mm the installation of an extra module will be mandatory in order to
comply with the regulations.
Installation
1. Mounting the profile
a. Take the sensor modules out of the profile.
b. If the profile is longer than the door width, cut the profile. Make sure not to scratch the front cover.
c. Affix the profile on the intended mounting position leaving more than 20 mm (13/16") from door edge to attach the
endcap.
d. If necessary, drill two mounting holes of ø3.4 mm (ø1/8")and fix the profile.
e. When mounting a sensor on each side of the door, it is necessary to drill a wiring hole of ø12 mm to connect the sensor
modules. (See 3. Wiring)
1
NOTE
Make sure there is some space between the mounting clips and the mounting screws.
Make sure not to scratch the profile when making a hole.
2. Inserting the sensor module
The lens that is marked "Tx" must be positioned onto the corresponding door edge.
Refer to Detection area for the sensor module position. The sensor module can be inserted in reverse as shown below.
To do this,detach the mounting clip and rotate the sensor module by 180° and reattach the mounting clips.
NOTE
Make sure to fix the sensor modules firmly by the mounting clips.
Tx
ON
ON
[mm(inch)]
3. Wiring
Wire the cable to the door controller as shown below.
Secondary module
LED
Secondary module
module
NOTE
* When more than 1 main module is installed on the door leaf, make sure that only one power supply
cable is connected to the operator otherwise initialization can not be completed.
All other main units will automatically function as a secondary unit.
NOTE
Maximum of three sensor modules can be connected to one main module.
EN 61000-6-3:2007 +A1:2011/AC:2012
EN 61000-6-2:2005/AC:2005
EN 12978:2003 +A1:2009
EMC Directive 2014/30/EU
Detection object : EN 16005 CA reference body
W
W
= Door width
h
= Mounting height
d3
d1
= Secured area width
d2
= Distance from the leading edge
to the sensor module
d3
= Distance between sensor modules
n
= Number of sensor modules
W
h
d1
1900
760
(6'3")
(2'6")
(2 3/4")
2000
790
(6'7")
(2'7")
(2 3/4")
2100
825
(6'11")
(2'8")
(2 3/4")
2200
870
(7'3")
(2'10")
(2 3/4")
2300
895
(7'7")
(2'11")
(2 3/4")
2400
920
(7'10")
(3')
(2 3/4")
2500
950
(8'2")
(3'1")
(2 3/4")
3000
1140
(9'10")
(3'8")
(2 3/4")
Silver screw
2
Power supply cable
Secondary module
Door
Main module *
Each module has three communication connectors.
Use the most convenient connector for the
installation site.
EN ISO 13849-1:2015
EN ISO 13849-2:2012
A. Maekawa
General Manager
OPTEX CO., LTD.
Quality Control Dept.
[mm(inch)]
900 (2'12")
1100 (3'7")
1200 (3'11")
d2
n
d3
n
d3
n
d3
70
175
475
375
2
2
2
2
2
2
(6 7/8")
(14 3/4")
(18 5/8")
70
160
360
460
2
2
2
(6 3/8")
(14 2/8")
(18 1/8")
70
145
345
445
2
2
2
(5 6/8")
(13 5/8")
(17 1/2")
70
120
320
420
2
2
2
(4 3/4")
(12 5/8")
(16 4/8")
70
115
315
415
2
2
2
(4 1/2")
(12 3/8")
(16 2/8")
70
110
310
410
2
2
2
(4 3/8")
(12 2/8")
(16 1/8")
70
100
300
400
2
2
2
(3 7/8")
(11 6/8")
(15 3/4")
70
30
230
330
2
2
2
(1 1/8")
(9")
(13")
Black screw
(small)
Min. 20 mm
(13/16")
1
2
3
Communication cable
LED
module
Door
controller

Advertisement

loading

Summary of Contents for Optex PROSWING OA-EDGE T

  • Page 1 OA-EDGE T Machinery Directive 2006/42/EC EMC Directive 2014/30/EU General Manager Notified Body 0044 : TÜV NORD CERT GmbH Am TÜV 1, 45307 Essen Germany OPTEX CO., LTD. For technical document, see European Subsidiary Quality Control Dept. Detection area Original instructions...
  • Page 2 EN 16005 Self monitoring Manufacturer Set dipswitch B3 to "ON". mode OPTEX CO., LTD. When dipswitch B3 is set to "OFF", it excludes conformity of the door system according to EN 16005. 5-8-12 Ogoto Otsu 520-0101, Japan www.optex.net By selecting the sensor position the outputs & LED indicator will...

This manual is also suitable for:

Proswing oa-edge t m 340blProswing oa-edge t m 340sProswing oa-edge t s 340blProswing oa-edge t s 340sProswing oa-edge t m 700blProswing oa-edge t m 700s ... Show all