Interlock continuity Test

WARNING : FOR CONTINUED PROTECTION AGAINST EXCESSIVE RADIATION
EMISSION,REPLACE ONLY WITH IDENTICAL REPLACEMENT RARTS.
TYPE NO. SZM-V 16-FA-63 OR VP-533A-OF FOR PRIMARY / SECONDARY SWITCH
TYPE NO. SZM-V 16-FA-62 OR VP-532A-OF FOR MONITOR SWITCH
A. PRIMARY INTERLOCK SWITCH TEST
When the door button is slowly depressed with the
door closed, an audible "click" should be heard at
the same time or successively at intervals. When
the button is slowly released, the latches should
activate the switches with an audible "click".
If the latches do not activate the switches when the
door is closed, the switches should be a adjusted in
accordance with adjustment procedure. Disconnect
the wire lead from the primary switch. Connect the
multimeter leads to the common (COM) and
normally open (NO) terminal of the switch. The
meter should indicate an open circuit in the door
open
condition.
When the door is closed, the meter should indicate
a closed circuit.
When the primary switch operation is abnormal,
make the necessary adjustment or replace the
switch only with the same type of switch.
COMPONENTS
SWITCHES
(Wire leads removed)
TEST PROCEDURE
Check for continuity of the switch
with a Multi-meter
Primary
Switch
Monitor
Switch
Secondary
Switch
NOTE: After checking for the continuity of switches, make sure that are
correctly connected.
B. SECONDARY INTERLOCK SWITCH TEST
Disconnect the wire lead from the secondary switch.
Connect the multimeter leads to the common (COM)
and normally open (NO) terminals of the switch. The
meter should indicate a open condition. When the
door is closed, meter should indicate an closed
circuit. When the secondary switch operation is
abnormal, make the necessary adjustment or
replace the switch only with the same type of switch.
C. MONITOR SWITCH TEST
Disconnect the wire lead from the monitor switch.
Connect the multimeter leads to the common (COM)
and normally close (NC) terminals of the switch. The
meter should indicate closed circuit in the door open
condition. When the door is closed, meter should
indicate an closed circuit.When the monitor switch
operation is abnormal, replace the same type of
switch.
NO
COM
NC
COM
NO
COM
5-8
RESULTS
Door
Door
open
close