1. Brief Introduction to the road gate machine 1.1 Functional Features * Left and right movement is adjustable * Road gate movement adopts crank shaker drive mechanism, compact structure, rigid rigidity, convenient maintenance and operation; * When the gate rod is in the horizontal or vertical state, the movement structure is completely self-lock, which can effectively protect the reducer from external force impact;...
3.Installation of road gate machine 3.1 Construction preparation: 1. Determine the gate pre-installation position according to the selected integrated gate direction and the field installation situation. The gate is divided into left fixed gate and right gate, defined as follows: facing the front of the main engine (no side of the main shaft), the right rod falls to the left fixed gate, and the lever falls to the left direction is the right fixed gate.As shown in the figure below:...
2. Remove the box and punch the mark with impact drill and place expansion bolts. 3. Place the box at the installation position, adjust the angle of the box, and tighten the expansion bolt nut after horizontal. 3.3 Gate bar installation (straight bar):...
Release all balance pull springs; Turn the motor hand shake handle and turn the brake clip to the horizontal position; Remove the lever and lever outer splint, double head bolt, gasket and cover nut; Place the splint and gate bar in the figure, insert the bolts, tighten the nut, and secure the gate bar;...
4. Introduction of the gate controller source Motor Function button status lamp Definition wiring terminal 4.1 Wiring instructions: 1. The start, stop, off and public are the gate control signal input, which can be connected to three manual buttons, and the camera opening input is connected to the start and public, regardless of sequence.Close the gate input access to the off-gate and public, regardless of order.
2. The ground sense and public are connected to the brake detector or radar output signal to control the vehicle over the gate. 3. Anti-smash and public for infrared access. 4.2 Explanation of operating terms: Long press: press and hold the button without release, such as: long press for 3 seconds for at least 3 seconds, until the LED display menu item and buzzer prompt.
4.5 Parameter setting steps: It can be set by long pressing the Menu / Confirmation button for 3 seconds, and the LED will display PXX. Select the menu item by short pressing or long pressing "Lift / +" and "drop / -", and add one once Or subtract one, long press is continuous add or subtract.Press Menu again to set up the specified item and press Stop /...
Page 11
Windows remarks menu function scope default Lift the brake speed 20-100 The larger the value, the faster the speed P-01 P-02 Landing speed 20-100 The larger the value, the faster the speed Lift the first part of the P-03 10-60 Start the to start slow stroke, unit: degree brake for the deceleration stroke...
Page 12
Detailed solution of parameters: P-01, gate lift speed All where the speed is involved, the percentage of the maximum speed of the motor is taken. If the maximum speed of the motor is 1800rpm and the set value is 80, the maximum speed runs at 1440rpm.
Page 13
parameter.For gates with rubber ring as a buffer, this value needs to be increased to avoid squeezing the rubber ring with each opening. P-11 This parameter sets a low speed uniform speed zone during the lift.During the lift, at this angle, at P-07 until it is completely closed. P-12 This parameter sets a uniform zone during the trip.During the trip, at this angle, P-08 will end until it is completely closed.
Page 14
Range: 30-90, default: 70. The maximum allowable force when operated by the motor, the greater the value, the greater the strength. P-21 Motor type / direction of rotation Value range: 0-5, default: 0. Because the pole logarithmic of the motor, the deceleration series of the gate movement is different, the gate has the left and right out of the pole.So this parameter is used for being compatible with various types of motors and gates.0 and 1,2 and 3,4 and 5 are corresponding in pairs.
Range: 2-50, default: 5, unit: 0.1 seconds.To prevent the violent shaking of the brake rod, the motor needs to slow down to zero within the set time to eliminate the jitter. P-28, gate lift is preferred Range: 0-1, the default: 0. In some scenarios require invalid shutdown and stop during lifting the rod.
Page 16
2. Schematic diagram of lifting the brake...
5. Road gate test 5.1 Gate bar position (levelness, verticality) adjustment: The gate has used the horizontal ruler to adjust the horizontal degree and verticality as the best position. If the site needs to adjust the position of the gate rod, adjust according to the following way 1.
2. Vertical gate adjustment (take the left fixed machine as an example) Long press the menu key, add the parameter key to the P10 key, and then press the menu key to see the specific parameter value of the p10 key. If the pole is not in place (less than 90 degrees), you can reduce the value, and then press the menu button to save.(Reducing the parameters of P10 increases the rod lifting stroke, making the rocking rod closer to the mechanical limit...
E06: Motor overcurrent protection E07: Motor Hall is missing E08: Motor start-up failed E09: Motor Hall order is wrong 8. Appendix: Spring ratio table Schematic diagram of the spring hole position...