Page 4
CUDO® CUBES Reshaping the Future of Stormwater Management A new approach to underground stormwater storage, infiltration, Potential LEED® credits for Sustainable Sites (6.1, 6.2), Materials & Resources (4, 5 in CA, AZ, NV, OR, UT) and treatment, harvesting or other Water Efficiency (1, 3) stormwater management needs.
Page 7
Product Specification - Structural Geogrid BX1200 Tensar Earth Technologies, Inc. reserves the right to change its product specifications at any time. It is the responsibility of the specifier and purchaser to ensure that product specifications used for design and procurement purposes are current and consistent with the products used in each instance. Please contact Tensar Earth Technologies at 800-836-7271 for assistance.
Page 8
® Mirafi 140NC ® Mirafi 140NC is a non-woven geotextile composed of polypropylene fibers, which are formed into a stable network such that the fibers retain their relative position. Mirafi 140NC is inert to biological degradation and resists naturally encountered chemicals, alkalis, and acids.
CUDO Stormwater System Underground Retention/Detention/ Infiltration/Water Reuse Systems Product Specifications PART 1 – GENERAL 1.01 General Provisions A. The Conditions of the Contract and all Sections of Division 1 are hereby made a part of this Section. 1.02 Description of Work A.
Page 12
CUDO Technical Specifications 1.04 Submittals A. Submit manufacturer’s product data and installation instructions. B. Submit CUDO module for review. Reviewed and accepted samples will be returned to the Contractor. C. Submit material certificates for geotextile, geogrid, base course and backfill materials. 1.05 Delivery, Storage, and Handling A.
Page 13
CUDO Technical Specifications PART 2 – PRODUCTS 2.01 Availability A. Manufactured by Oldcastle Precast, 7100 Longe Street, Stockton, California, 95206. 2.02 Materials A. Base of excavation: Shall be smooth, level and free of lumps or debris. B. Geotextile: Use non-woven geotextile with weight of at least 4 oz per square yard, appropriate for the soil type and depth conditions.
Page 14
CUDO Technical Specifications C. Installation constitutes acceptance of existing conditions and responsibility for satisfactory performance. If existing conditions are found unsatisfactory, contact Project Manager for resolution. 3.02 Base Preparation A. Generally a base material of sand or stone should be used and be compacted to 95%. The specific nature of the material will depend upon a myriad of factors, including but not limited to soil reports and end use of system (detention or retention).
Page 15
CUDO Technical Specifications 3.04 Cleaning A. Perform cleaning during the installation of work and upon completion of the work. Remove from site all excess materials, debris, and equipment. Repair any damage to adjacent materials and surfaces resulting from installation of this work. Sample Installation Detail...
Page 17
CUDO Stormwater System Underground Retention/Detention/ Infiltration/Water Reuse Systems Installation Manual...
Page 18
CUDO Installation Guide CUDO Cube Modular Stormwater System CUDO Assembly The CUDO product will arrive onsite with the required number of components to complete your project. Those components will consist of (as required) CUDO half cubes, top/bottom grates, stacking couplers, side plugs, and/or lateral connectors.
Page 19
CUDO Installation Guide Site Excavation The contractor shall excavate the site to the width, depth and length necessary to accommodate and install the CUDO stormwater system including provisions for cover over the system and depth below the system in accordance with the project engineer’s specifications. Base Preparation Generally a base material of sand or stone should be used and be compacted to 95%.
Page 21
CUDO® CUBES Operations and Maintenance Manual (Underground Retention / Detention / Infiltration / Water Reuse Systems)
Page 22
CUDO® Stormwater Cube - Modular Stormwater Systems Description / Basic Function CUDO is a modular stormwater system comprised of a grouping of modular polypropylene or concrete cubes that when constructed form an underground storage area for stormwater. This system can be used for infiltration, retention, detention or water reuse.
Page 23
Maintenance Overview for CUDO State and Local regulations require that stormwater storage systems be maintained and serviced on a recurring basis. The purpose of maintaining a clean and obstruction free CUDO system is to ensure the system performs the intended function of the primary design.
Page 24
Maintenance Cleanout of the CUDO system should be considered if there is sediment buildup of two or more inches at over 50% of the inspection ports. Cleaning shall be performed if sediment buildup is two inches or more over 75% of the system floor.
Page 25
CUDO® CUBES OUR MARKETS BUILDING COMMUNICATIONS ENERGY TRANSPORTATION STRUCTURES WATER www.oldcastlestormwater.com 800-579-8819...