Gives you an example of a specific subject. DS-IRIG-ACDC2 converts IRIG code B-DC and -AC signals, so that they can be used to synchronise different Dewesoft devices. The input source can be changed via push-button and is indicated by three LEDs. ...
DC IRIG-DC (L0B4f) Sirius Input level TTL / CMOS compatible Input configuration Non isolated, single ended Output specifications IRIG-DC (BNC) TTL compatible IRIG-DC (L0B4f) Sirius TTL compatible IRIG-DC OUT (L0B2f) Sirius (differential) RS 422 compatible (differential) DS-IRIG-ACDC2 V20-1 4/12 ...
Page 5
-5°C to +60°C Storage temperature -30°C to +85°C Relative humidity 0 to 95% @ 60°C, non-condensing Illustration 1: Front and back connectors Adjusted to Meinberg, can be adjusted to different values in factory DS-IRIG-ACDC2 V20-1 5/12 ...
5.2. Support Dewesoft has a team of people ready to assist you if you have any questions or any technical difficulties regarding the system. For any support please contact your local distributor first or Dewesoft directly. ...
When used in text representing the company, product or technology name, the ® sign is not used. The Dewesoft triangle logo is a registered trademark but the ® sign is not used in the visual representation of the triangle logo. ...
Failure to comply with these precautions or with specific warnings elsewhere in this manual violates safety standards of design, manufacture, and intended use of the product. Dewesoft GmbH assumes no liability for the customer’s failure to comply with these requirements. ...
REMOVE POWER and do not use the product until the safe operation can be verified by service-trained personnel. If necessary, return the product to Dewesoft sales and service office for service and repair to ensure that safety features are maintained. ...
Page 10
This product has left the factory in safety-related flawlessness and in proper condition. In order to ● maintain this condition and guarantee safety use, the user has to consider the security advice and warnings in this manual. EN 61326-3-1:2008 DS-IRIG-ACDC2 V20-1 10/12 ...
Page 11
Devices and systems according to IEC 61508 or IEC 61511 which are considered as “operationally well-tried”, are excluded from the scope of IEC 61326-3-1. Fire-alarm and safety-alarm systems, intended for the protection of buildings, are excluded from the scope of IEC 61326-3-1. DS-IRIG-ACDC2 V20-1 11/12 ...
DS-IRIG-ACDC2 TECHNICAL REFERENCE MANUAL 7. Documentation version history Version Date Notes V20-1 7.10.2020 New template DS-IRIG-ACDC2 V20-1 12/12 ...