    TABLE OF CONTENTS Page 1. Important information and legal notices ........3 2.
  • Page 3: Important Information And Legal Notices

    Beinlich accepts no liability for possible printing errors. Reproduction, even in excerpt form, is permitted only following written consent from Beinlich. Beinlich reserves the right to make technical modifications at any time. Last updated: 05/2023...
  • Page 4: General Information

    Store these operating instructions near the instructions. In the context of continued development, pump. Beinlich Pumpen GmbH reserves the right to make changes to the individual components or assemblies that are deemed to make sense for the improvement of the product while maintaining the main characteristics.
  • Page 5: Safety And Warning Signs

    3. SAFETY AND WARNING SIGNS You must comply with all safety warnings in the operating instructions that are identified as followed: Warning of mechanical hazard Read the operating instructions/ comply with regulations Warning of hot surface Enable Warning of hazardous electric voltage Secure Important information for safe and Information, tips...
  • Page 6: General Safety Instructions

    VDE, for example, and the energy supply companies). Electrical connec- tions must be installed by trained personnel. Opening of the pump during the warranty period is only permitted following consultation with and approval from Beinlich Pumpen GmbH!
  • Page 7: Safety Instructions For Maintenance / Inspection And Assembly Work

    4.2 Safety instructions for maintenance / inspection and assembly work The operator must make ensure that all maintenance, in- Any work on the pump must be performed when spection and assembly work is exclusively performed by the pump is at standstill. authorized qualified specially trained personnel who are Adherence to the procedures that are described in the sufficiently informed after carefully studying the opera-...
  • Page 8: Commissioning - Preparation Work

    6. COMMISSIONING – PREPARATION WORK The pump must only be commissioned when: •Sealing caps and protective covers are not damaged. • The information of the technical specifications in the •There are no visible leaks. order confirmation matches the information in the use conditions.
  • Page 9: Storage, Return And Disposal

    8. STORAGE, RETURN AND DISPOSAL Storage Disposal All Beinlich pumps are supplied with sealing plugs and Beinlich actively promotes environmental awareness in suitable packaging for all destinations and modes of and has an operational management system that meets transport to ensure optimum protection. The pumps should the requirements of ISO 9001:2015.
  • Page 10: Maintenance, Service Life And Warranty

    9. MAINTENANCE, SERVICE LIFE AND WARRANTY Beinlich gear pumps are maintenance free under Depending on the operating conditions, the service standard conditions. A continuous control of the technical life and therefore the specific properties of the pumps parameters is recommended. The use of corresponding are limited by wear, corrosion, deposits or ageing.
  • Page 11: Disassembly Of The Pump

    10.2 Disassembly of the pump 10.2.1 Pull the key (4) off the shaft 10.2.2 Unscrew the 4 cylinder bolts M6 (1) 10.2.3 Carefully remove the front plate (6) 10.2.4 Pull the drive shaft with gear out (7, 9, 10) 10.2.5 Pull the driven gear out (8) 10.2.6 Remove the circlip (10) 10.2.7 Pull the gear off the shaft Note...
  • Page 12: Shaft Seal Disassembly

    Note The front plate must be disassembled to remove the radial shaft seal. See Disassembly Instructions (10.2.1 – 10.2.3) 10.5 Shaft seal disassembly 10.5.1 Remove the key (4) 10.5.2 Remove the locking ring (2) 10.5.3 Remove the front plate (see Disassembly 10.2.1 – 10.2.3) 10.5.4 Remove the support ring (3) (does not apply to PTFE version) and remove the radial shaft seal (5) 10.6 Assembly...
  • Page 13: Spare Parts

    11. SPARE PARTS Provide the following information to place orders for nal view is available for ordering spare parts. We ad- spare parts: vise explicitly that spare parts and accessories that are •Order No. not supplied by us are not checked and approved by us. •Item no.
  • Page 14: Certificate Of Non-Objection

    SAFETY DECLARATION (CERTIFICATE OF NON-OBJECTION) Last revised: 04/2023 Please reply to reparaturen@beinlich-pumps.com Pumps for which this safety certificate has not been completed and signed can neither be inspected nor repaired for safety reasons and will be returned unchecked at your expense.
  • Page 15 The undersigned is liable for all damages which arise as a result of the non-marked decontamination of the returned pump. Beinlich expressly points out that repairs and verification work is carried out by trusting the correctness of the completion of this safety declaration (certificate of non-objection). Should physical injuries, death or even damage to property occur, claims for damages will be asserted.
  • Page 16 Beinlich Pumpen GmbH Gewerbestraße 29 58285 Gevelsberg/Germany Phone +49 (0) 23 32 / 55 86 0 TÜV NORD CERT GmbH info@beinlich-pumps.com www.beinlich-pumps.com...