Installation (continued)

MOUNTING THE UTILITY SINK

1 . Carefully place a bead of sealant all around the top of the
cabinet .
2 . Ease the sink onto the cabinet, and ensure it is placed
evenly and centered on the cabinet . Wipe off any excess
sealant . Use masking tape to hold the unit in place until the
sealant dries .

PLACEMENT

Move the assembled unit to its final location. Final hook up of the supply lines and drain system can now be completed.
SUPPLY LINES (NOT INCLUDED)
The supply lines that attach the faucet to the household
water system, are not supplied with this unit . They need to be
purchased separately .
Follow the manufacturers instructions for proper installation of
the supply lines .

Maintenance

CARTRIDGE REPLACEMENT

To replace the cartridge, please follow these steps:
1 . Turn off the water supply to the faucet .
2 . Remove water indicator (7) and screw (5) with an Allen key .
3 . Remove the handle (6) .
4 . Screw off the cartridge cover (4) .
5 . Remove the gasket (3) .
6 . Pull out the cartridge (2) by hand .
7 . Click in the new cartridge .
8 . Place the gasket (3) back in its original position .
9 . Screw on the cartridge cover (4) . Do not over tighten .
10 . Place the handle (6) over top and secure the screw (5) with
an Allen key, replace the water indicator (7) .