Please read this manual carefully and completely before you use the device for the first time. The device may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no warranty of damages or injuries caused by non-observance of the manual.
PM 2.5 & PM 10 0 … 2000 ug/m³ Measurement range Resolution 1 ug/m³ Delivery 1 x particle counter PCE-PCO 1 or PCE-PCO 2 1 x zero filter 1 x battery 1 x charger 1 x USB cable 1 x user manual...
Pause measurement Alarm active Camera mode Video mode Instructions PCE-PCO 1 PCE-PCO 2 • Select the menu item "particle measurement" and confirm with Enter. The following image (picture on the left side) appears on the display. The picture on the right-hand side appears depending on your settings (PCE-PCO 2 only).
Press F3 while you are in the menu item „particle counters“ to enter the settings menu. • Use the arrow button to navigate and confirm your choice by pressing Enter. • Press ESC to terminate the function. PCE-PCO 1 PCE-PCO 2...
Start the input with Enter. • Use the arrow keys to adjust the measurement time. • Confirm your entry with Enter PCE-PCO 1 & PCE-PCO 2 5.3.2 Start Delay • Start the input with Enter. • Use the arrows to adjust the start delay.
Manual 5.3.5 Sample Cycle In this menu you can set the number of measurements. PCE-PCO 1 & PCE-PCO 2 5.3.6 Sample Mode In this menu you can adjust the display mode of the particle counter. Cumulative - Differential - Concentration - PCE-PCO 1 &...
Manual 5.3.7 Interval In this menu you can set the pause between two measurement test runs. PCE-PCO 1 & PCE-PCO 2 5.3.8 Level Indication In this menu you can set which particle sizes you wish to be displayed. • Use the arrow buttons to choose between the particle sizes.
• Use the arrow button to navigate in the system settings and confirm your choice by pressing Enter. PCE-PCO 1 & PCE-PCO 2 Menu item Description Date / Time Set time and date Font Colour...
Manual 5.5.3 Language • Use the arrow to select a language. • Press ESC to save the settings and exit the menu. 5.5.4 Brightness • Use the arrow to set the required brightness. • Press ESC to save the settings and exit the menu.
Manual 5.5.8 Memory Status • Use the arrow to choose between the internal memory and the SD card. • Press ESC to save the settings and exit the menu. Formatting • Press F1 to format the selected memory. • Press F1 to confirm or F3 to discard. 5.5.9 Factory Settings •...
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use them or give them to a recycling company which disposes of the devices in line with law. If you have any questions, please contact PCE Instruments. 10 Contact If you have any questions about our range of products or measuring instruments please contact PCE Instruments.
Need help?
Do you have a question about the PCE-PCO 1 and is the answer not in the manual?