enphase Dimplex SI 6TU Installation And Configuration Manual
enphase Dimplex SI 6TU Installation And Configuration Manual

enphase Dimplex SI 6TU Installation And Configuration Manual

Heat pump system

Advertisement

Quick Links

INSTALLATION AND CONFIGURATION MANUAL (PRELIMINARY)
SG Ready installation and configuration:
Dimplex SI 6TU / 8TU / 11TU / 14TU / 18TU heat pump system

Table of contents

Safety ................................................................................................................................................................................ 2
Read this first .................................................................................................................................................. 2
Safety instructions ......................................................................................................................................... 2
Corporate headquarters contact information .......................................................................................... 3
Environmental protection ............................................................................................................................. 3
Other information .......................................................................................................................................... 3
Audience ......................................................................................................................................................... 3
Preface ............................................................................................................................................................................. 4
Scope of this document ................................................................................................................................ 4
Compatible heat pumps with this document ............................................................................................. 4
Optimizing the heat pump using the SG Ready interface ........................................................................................ 4
Performing the prerequisite checks ............................................................................................................................ 4
Hardware requirements ................................................................................................................................5
Connecting the heat pump and the SG Ready Relay ...............................................................................................5
Connection to Dimplex SI 6TU / 8TU / 11TU / 14TU / 18TU .......................................................................5
Configuring the heat pump system controller........................................................................................................... 7
Configuration of WPM_M.x (touch display) ............................................................................................... 8
Validating the configuration .........................................................................................................................................9
Commissioning the Enphase Energy System ........................................................................................................... 10
Appendix ......................................................................................................................................................................... 11
References ...................................................................................................................................................................... 11
Revision history ............................................................................................................................................................. 12
© 2023 Enphase Energy Inc. All rights reserved.
March 2023

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Dimplex SI 6TU and is the answer not in the manual?

Questions and answers

Summary of Contents for enphase Dimplex SI 6TU

  • Page 1: Table Of Contents

    INSTALLATION AND CONFIGURATION MANUAL (PRELIMINARY) SG Ready installation and configuration: Dimplex SI 6TU / 8TU / 11TU / 14TU / 18TU heat pump system Table of contents Safety ....................................2 Read this first ..............................2 Safety instructions ............................2 Corporate headquarters contact information ..................3 Environmental protection ..........................
  • Page 2: Safety

    Do not attempt to repair the SG Ready Relay. It contains no user-serviceable Risk of electrocution! parts. Tampering with or dismantling the SG Ready Relay will void the warranty. If the equipment fails, contact Enphase Customer Support (enphase.com/support) for assistance or replacement equipment. DANGER: Risk Do not use SG Ready Relay in a manner not specified by the manufacturer.
  • Page 3: Corporate Headquarters Contact Information

    User documentation is updated frequently; Check the Enphase website (enphase.com/support) for the latest information. Enphase did not author and does not take any responsibility for the functionality or accuracy of information for third party content linked in this document. Copyright © 2023 Enphase Energy Inc. All rights reserved.
  • Page 4: Preface

    Installer App. • Activate the Enphase IQ Energy Router and configure it such that it can detect and connect to the other components such as SG Ready Relay or Energy Meter referred to in this documentation. © 2023 Enphase Energy Inc. All rights reserved.
  • Page 5: Hardware Requirements

    To set up the SG Ready functionality, it is needed to connect the SG Ready Relay with the heat pump indoor unit or controller of the heat pump via wires. Depending on the heat pump indoor unit or controller the cable connection might be different. Connection to Dimplex SI 6TU / 8TU / 11TU / 14TU / 18TU Source: Dimplex ©...
  • Page 6 4. Connect the wires from the SG Ready Relay with the digital inputs N1-J5/ID1 & N1-J5/ID2 and X3/G. The colors of the wires are not relevant. AA2 board inputs SG Ready Relay outputs N1-J5/ID1 N1-J5/ID2 X3/G X3/G © 2023 Enphase Energy Inc. All rights reserved. March 2023...
  • Page 7: Configuring The Heat Pump System Controller

    Depending on the system controller of the heat pump, the activation and configuration of the SG Ready function can be different. Go to the display of your heat pump. Source: Dimplex © 2023 Enphase Energy Inc. All rights reserved. March 2023...
  • Page 8: Configuration Of Wpm_M.x (Touch Display)

    4. Click the Enter button to confirm with details. Source: Dimplex WARNING: If you need help with the login, contact the responsible heat pump installer. 5. Now you should see the Specialist view. Source: Dimplex © 2023 Enphase Energy Inc. All rights reserved. March 2023...
  • Page 9: Validating The Configuration

    1 second. Now the LED 2 should glow red. 10. The test and commissioning were successful. WARNING: If your test failed or you experienced any issues, please contact Enphase Customer Support. © 2023 Enphase Energy Inc. All rights reserved. March 2023...
  • Page 10: Commissioning The Enphase Energy System

    Commissioning the Enphase Energy System The last step involves commissioning the EES. Open the Enphase Installer App. Go to the support section of Enphase Installer App where you can find all relevant documentation needed to commission the EES. Note: Contact Enphase Customer Support if you experience any issues and need help.
  • Page 11: Appendix

    SI 6TU / 8TU / 11TU / 14TU / 18TU • “Montage- und Gebrauchsanweisung, Sole-Wasser-Wärmepumpe für Innenaufstellung“ (published: 01.2021) https:/ /dimplex.de/productfinder_assets/Web- Media/Montageanweisungen_SYS/2_Sole/dimplex_si6-18tu_fd0106_de-en-fr.pdf Heat pump manager • “Operating instructions, for technicians” https:/ /dimplex.de/productfinder_assets/Web- Media/Montageanweisungen_SYS/6_Regler/neutral_wpm-ia-l20_fd9309_de-gb-fr.pdf • “Electrical documentation” https:/ /dimplex.de/productfinder_assets/Web- Media/Montageanweisungen_SYS/6_Regler/neutral_wpm-econ5-ea_fd9407_de-gb-fr.pdf © 2023 Enphase Energy Inc. All rights reserved. March 2023...
  • Page 12: Revision History

    Heat pump manager and SG Ready • Dimplex Wiki https:/ /dimplex.atlassian.net/wiki/spaces/DW/pages/2862579724/KNX+WPM • PHB Wärmepumpen für Heizung und Warmwasserbereitung (published: 07.2014) https:/ /www.dimplex- partner.de/fileadmin/dimplex/downloads/projektierungshandbuecher/de/PHB_WP_Heizen_07_201 4.pdf Revision history Revision Date Description Rev 1 March 2023 Initial release © 2023 Enphase Energy Inc. All rights reserved. March 2023...

Table of Contents