Table of Contents

Advertisement

SERVICING YOUR GENERATOR

FUSE

If the fuse is blown, the starter motor won't operate.
In the event of fuse failure, locate the cause of failure and repair it before you
continue operation. If the fuse continues to fail, discontinue generator use and
consult an authorized Honda Power Equipment dealer.
1. Turn the engine switch to the OFF position and remove the key before
checking or replacing the fuse.
2. Remove the fuse holder cover and
pull the fuse out.
3. Replace the fuse with a fuse of the
same type and rating.
Specified fuse: 20 A
Never use a fuse with a different
rating from that specified.
Serious damage to the electrical
system or fire may result.
4. Install the fuse holder cover in the reverse order of removal.