3.2
DispLaY GeneraL
By pressing the < (forward) and > (backward) buttons
the display will cycle through the options. Press enter
button when the option you require is displayed.
Battery type:
Regular liquid.
AGm Flat Plate.
AGm spiral.
Gel.
3.3
BatterY test
3.3.1
With battery test screen displayed
press ENTER.
3.3.2
Use the < (forward) and > (backward)
buttons to select the battery type:
Regular Liquid, AGm Flat Plate, AGm
spiral or Gel.
.
Press ENTER to confirm choice.
3.3.3
Use the < (forward) and > (backward)
buttons to select the battery rating: sAE,
EN, IEC, DIN or JIs.
Press ENTER to confirm.
3.3.4
Use the < (forward) and > (backward)
buttons to input the battery capacity.
CCA:
DIN:
25 - 1300
EN:
40 - 2100
IEC:
30 - 1500
JIs:
By battery type
sAE:
40 - 2000
Press ENTER to begin test.
3.3.5
Battery being tested for a few seconds.
3.3.6
Press < (forward) or > (backward) buttons
to select battery fully charged: Yes or no.
Press ENTER to confirm choice.
3.3.7
When the test is complete, the LCD
shows the actual volts and CCA
Press < (forward) or > (backward) buttons
to select: sOH (state of Health) or sOC
(state of Charge).
One of the following results will be
displayed.
3.3.8
GOOD & pass: Battery is capable of
holding a charge.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMpOrtant: No liability is accepted for incorrect use of this product.
WarrantY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inFOrMatiOn: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
sole uK Distributor, sealey Group,
Kempson Way, suffolk Business Park,
Bury st. Edmunds, suffolk,
IP32 7AR
Original Language Version
3.3.9
GOOD & reCHarGe: The battery is
good but needs to be recharged.
3.3.10
reCHarGe & retest: Battery is
discharged, the battery condition cannot
be determined until it is fully charged.
Recharge and retest.
3.3.11
BaD & repLaCe: The battery will not
hold its charge. Replace.
3.3.12
BaD CeLL & repLaCe: The battery
has at least one cell short circuit. Replace.
3.3.13
LOaD errOr: The tested battery is
larger than 2000CCA or 200Ah. Or the
clamps are not connected properly. Please
fully charge the battery and retest after
excluding both previous reasons. If reading
is the same, the battery should be replaced
immediately.
NOTE! The operator is asked if any accessories
are left on as a possible cause. If
accessories are left on, the operator is
instructed to charge and retest the battery.
If accessories are not left on, the operator
is instructed to replace the battery since
the charging system is working and a good
battery should have accepted a charge.
3.3.14
Press < (forward) or > (backward) buttons
to select result printing: Yes or No. Press
ENTER to confirm choice.
3.3.15
Press ENTER to return to the start screen
or remove the clamps from the battery
after completion of testing.
01284 757500
01284 703534
Use the < (forward) and > (backward)
buttons to select language or press
ENTER to commence battery test
Use the < (forward) and > (backward)
buttons to return to battery test or press
ENTER to set language.
Use the < (forward) and > (backward)
buttons to select language.
English, French, German, spanish,
Italian, Portuguese or Japanese.
Press ENTER to confirm choice and
return to battery test.