Do you have a question about the SmartCabinet2-E Series and is the answer not in the manual?
Questions and answers
Summary of Contents for Vertiv Tech SmartCabinet2-E Series
Page 2
Version V1.30 Revision Date 2020-06-18 Vertiv Tech Co., Ltd. provides customers with technical support. Users may contact the nearest Vertiv local sales office or service center. Copyright by Vertiv Tech Co., Ltd. All rights reserved. The contents in this document are subject to change without notice.
Page 3
Safety precautions 1. Keep this manual throughout the life of the product. 2. Users should read this manual carefully before performing any operation on the product. 3. “Notices” and “Warnings” in this manual do not represent all safety precautions to be observed, but they are only supplements to various operational safety precautions.
Page 4
In thunderstorms, a strong electromagnetic field will be generated in the air. Therefore, equipment should be well earthed in time to avoid damage by lightning strikes. Static electricity generated by the human body will damage the static sensitive elements, such as large- scale integrated circuits (ICs), on the circuit board.
The SmartCabinet 2-E series of computer room solution products (referred to as SmartCabinet 2-E products for short) are the data cabinet solution products produced by Vertiv Tech Co., which are applied to micro data centers, office areas and other indoor environments. The SmartCabinet 2-E products are used for installation and placement...
When installing SmartCabinet 2-E, enough space should be reserved to facilitate the installation and maintenance of cabinets. The required space for opening the front and rear doors of the cabinet is shown in Figure 1-3. SmartCabinet2-E Series Computer Room Solution Product User Manual...
AC220V and DC12V/24V output, and provides a safe and reliable power supply system for the whole system and IT load. The SmartCabinet 2-E product integrates the latest ITA2 6kVA UPS, provides distribution support for IT load, air conditioner equipment, ECO module, monitoring system and illumination system. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 11
ITA2 6kVA UPS (hereinafter referred to as UPS for short) is an intelligent, on-line, sinusoidal uninterruptible power supply system developed by Vertiv Tech Co., Ltd. It can provide reliable and high-quality AC power supply for precision instruments and equipment. The UPS can be assembled into tower or rack type as required. This equipment is suitable for AC power supply of small computer center, network, communication system, automatic control system and precision instrument equipment.
The grounding resistance of the whole unit is <0.1, and the current can withstand ≥25A. 1.7 Technical Specifications Table 1-7 SmartCabinet2-E Technical Specifications Input voltage 220Vac/230Vac/240Vac(phase) Power supply and distribution system Input voltage range AC176V~288V SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 13
R410A Cooling system Certification CE Certification Weight 45kg 1 groups: rear door top (self-starting: high temperature alarm in the Emergency fan unit(ECO cabinet, and ambient temperature lower than cold passage module) temperature) SmartCabinet2-E Series Computer Room Solution Product User Manual...
Tighten the screws when assembling the parts, recommended size: 1X300 Flat-blade screwdriver Dismantle wooden box steel tongue Claw hammer Dismantle wooden box steel tongue Levelling meter Displays the horizontal status of the cabinet system when it is leveled SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 15
Name Purpose Appearance Quantity Used with M6 screws for the installation of user parts Floating nut in the cabinet M6x16 panel screws Used for the installation of user parts in the cabinet SmartCabinet2-E Series Computer Room Solution Product User Manual...
Figure 2-2 Hand Pallet Truck & an Electric Forklift When unloading and transporting with “land cow” or electric forklifts, it is recommended that the fork is at the center of gravity to prevent tipping, as shown in the Figure 2-3. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Vertiv in time for proper disposal. 2) If you receive the carton packaging, use a utility knife to remove the packaging material, as shown in the Figure 2-5. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 19
4) Use a #19 wrench to screw the foot nut, lower the foot, and lift the cabinet. Remove the M8 bolt with the movable wrench and remove the foot-press plate, as shown in Figure 2-7. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 20
After the cabinet is placed on the ground, it needs to be leveled, and the inclination angle is less than 5°. 2. Cabinet placement The cabinet should be placed for future maintenance, as shown in Figure 2-9. SmartCabinet2-E Series Computer Room Solution Product User Manual...
The fan cable is threaded into the cabinet from the top guard ring of the cabinet. Use a positioning pin to locate and fix the 2 PCs of M4x8 screws, as shown in Figure 2-11 & Figure 2-12. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 22
3) Connect the fan cable to the “+”, “-”, and “SS” Pins in the “FAN” area of the PMU rear terminal block according to Figure 2-14 and bind the cable along the way. Figure 2-14 ECO module wires connection SmartCabinet2-E Series Computer Room Solution Product User Manual...
The cabinet comes with a battery module. If you choose an extra battery module, you need to follow the steps below. 1) Unpacking the battery module for visual inspection, there should be no obvious damage to the appearance; Check the cable. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 24
No.5U position on the column, as shown in Figure 2-18. Figure 2-18 Install the floating nuts 1 4) Install the rails, fixe with M6×16 screws (8pcs), as shown in Figure 2-19. Figure 2-19 Install the rails SmartCabinet2-E Series Computer Room Solution Product User Manual...
Figure 2-22 Battery wires connection 2.2.6 GSM MODEM installation (optional) 1. Take out the GSM MODEM from the cabinet accessory bag. 2. Install the SIM card and GSM MODEM antenna according to Figure 2-23. SmartCabinet2-E Series Computer Room Solution Product User Manual...
2) Use the M5×12 screws (4pcs) to install the lowermost air duct in the air outlet of the rear door of the cabinet; 3)Splicing the remaining air ducts one section at a time and fixing them to the cabinet using the side panel screws nearby. Figure 2-25 Install the air duct SmartCabinet2-E Series Computer Room Solution Product User Manual...
0.6m. Connect to the “LAN1” port at the end of the PMU. Figure 2-28 Communication wires connection 2.2.9 Installation Inspection Check the installation against the installation checklist, and do not connect to the power and test the unit until the inspection is passed. SmartCabinet2-E Series Computer Room Solution Product User Manual...
The hardware installation and inspection work has been completed, the installation wiring is in place correctly. 2.3.3 Inspection Prior to powering on the SmartCabinet2-E product, check the following list: Table 2-7 Pre-commissioning checklist Inspection item Inspection standard Remarks SmartCabinet2-E Series Computer Room Solution Product User Manual...
1) On the main menu screen, press the arrow keys select the “Setup” menu and press the key to enter the corresponding page. See the Figure2-32. Figure 2-31 Main menu screen SmartCabinet2-E Series Computer Room Solution Product User Manual...
Warning The SmartCabinet2-E system must be started up by trained and authorized professional technicians. It is recommended to be performed by the staff of Vertiv Tech Co., Ltd. Customer Service Center. 2.3.5 System commissioning 1. After startup, the default display interface is displayed via the LCD.
"Cabinet Data" -> "Front Door" or "Rear Door" -> "Control ", click " Remotely open door" setting signal, as shown in the Figure 2-37 for the remote door opening control. After receiving the door lock signal, the field operator can open the corresponding cabinet door. SmartCabinet2-E Series Computer Room Solution Product User Manual...
5. Disconnect the UPS input MCB and output MCB. Disconnect the battery MCB (when the battery is selected). 6. Disconnect the total input MCB on the PMU. 7. Check that all electrical equipment has been completely powered off and close all doors. SmartCabinet2-E Series Computer Room Solution Product User Manual...
The system menu of the display panel is shown in the Figure 3-2. Figure 3-2 System menu 3.1.2 Startup Screen If SmartCabinet2-E intelligent monitoring unit has switched on, the screen is skipped automatically, and directed to the home page SmartCabinet2-E Series Computer Room Solution Product User Manual...
Figure 3-4 Password screen for entering the thermal management settings As shown in the Figure 3-5, the air conditioning temperature set point can be modified. The factory default setting point is 23°C, and the setting range is 18 to 27 °C. SmartCabinet2-E Series Computer Room Solution Product User Manual...
PDUs. As shown in the Figure 3-6, PDU1 can view specific parameters, PDU2 is not configured, and parameters cannot be viewed. Figure 3-6 PDU1 only After selecting two PDUs, you can view the parameters, as shown in the Figure 3-7. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 36
On the control page, you can view the on/off status of each PDU port and the customized interface name. (For the description of PDU custom port, please refer to the 3.2.4 menu items section's attention). Figure 3-9 Port control The PDU voltage and current range can be set on the setup page. SmartCabinet2-E Series Computer Room Solution Product User Manual...
(minor alarm, major alarm, critical alarm), and alarm time. By viewing the alarm information, the user can accurately understand the current system operation status, and timely process alarm information to ensure stable and safe operation of the system, as shown in the Figure 3-13. SmartCabinet2-E Series Computer Room Solution Product User Manual...
You can view all control information and control time of the user by viewing the control log, as shown in the Figure 3-15. For other control commands sent through the WEB page, please visit the WEB page to control the log query related operation records. SmartCabinet2-E Series Computer Room Solution Product User Manual...
The settings page includes six options for Language, Password, Network, System, Config and ECO. 1. Language Used to switch between two built-in LCD local display interface languages, as shown in the Figure 3-17. Figure 3-17 Language SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 40
In the maintenance mode, no alarm sound will be generated, and the alarm icon will change to To click, you need to cancel the maintenance mode on the system page. The system interface is shown in the Figure 3-20. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 41
The SmartCabinet2-E configuration page configures the number of PDUs, smart door locks, and fire subracks, as shown in the Figure 3-21. Figure 3-21 Configuration 6. ECO On the ECO page, you can set the ECO mode enable status and ECO entry humidity conditions. Figure 3-22 ECO settings SmartCabinet2-E Series Computer Room Solution Product User Manual...
Double-click the IE icon to run the software, click on the menu Tool → Internet Options, click on the Settings (S) in the General Tab, and change “Check for newer version of stored pages” to “Every time I visit the page”, as shown in the Figure 3-25: SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 43
Connections tab to pop up the page as shown in the Figure 3-26. Figure 3-26 Select Connection tab 2) In the page shown, click LAN Settings (L) to pop up the page as shown in the Figure3-27. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 44
Figure 3-28 Security Settings1 2) Select Local Intranet as shown in the Figure3-28, click Custom Level ..., and the dialog box shown in the Figure 3-29 will pop up. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 45
4) Set to enable File Download, as shown in the Figure 3-30. Figure 3-30 Enable file downloads 5) Set to enable the Initialization and scripts ActiveX controls not marked as safe for script, as shown in the Figure 3-31. SmartCabinet2-E Series Computer Room Solution Product User Manual...
As shown in the Figure 3-33, if the login page does not appear, see the 3.2.1 1. Check IE general settings. 2) On the login page, click to select the favorite theme style, represents crystal blue; represents ocean blue, as shown in the Figure 3-33. SmartCabinet2-E Series Computer Room Solution Product User Manual...
After logging in the MSC intelligent monitoring system successfully, the homepage is displayed by default, as shown in the Figure 3-35. 1. Homepage The home page effect is shown in the Figure 3-35: SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 48
Click the Select Type button to pop up the page as shown in the Figure.3-37. Click the Left(<) and Right(>) buttons to select the model image. After selecting, click the Select Type button and then click “OK”, the homepage will display the background image. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 49
Figure 3-39 Time-out status After clicking [Clear] timeout, the input box as shown in the Figure 3-40 appears. After the login password verification is passed, the controllable state returns to normal after about 5 seconds. SmartCabinet2-E Series Computer Room Solution Product User Manual...
3. List of available 4. Back to browse 5. Restore system 2. Configuration control icon icon controls icon icon 7. Same type of equipment effectively 6. Save icon icon Figure 3-42 Equipment Overview SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 51
Figure 3-45. 4. Enter a self-defined port name in the dialog box and click OK to complete the self-defined setting of PDU port name. Figure 3-45 Port Name Modification Dialog Box SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 52
Figure 3-48. Figure 3-48 Server Shutdown settings page In the Server Shutdown settings page, users can add and remove server shutdown tasks. The steps to add the server shutdown are as follows: SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 53
When equipped with a fire subrack accessory, you can set the linkage control between fire subrack and air conditioner and UPS on this page. 2) Video Surveillance Click on the Video Surveillance submenu under the Safe Mgmt. menu and the page shown will be displayed. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 54
Figure 3-52 Internet Settings b) Realtime video Click on the Live Video tab under the Video Surveillance menu and the page shown will be displayed. The following Table 3-1 gives the icon description. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 55
Video Replay Click the Video Replay tab under the Video Surveillance menu, and the page shown in the Figure 3-54 will be displayed. The following Table 3-2 gives the corresponding icon description. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 56
Single frame play Capture Download playback video file Set the sound volume d) Video settings Click the Video Settings tab under the Video Surveillance menu and the page shown will be displayed. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 57
The captured video can be viewed through the Video Replay tab under the Video Surveillance menu. Figure 3-57 Snapshot Download Notices The video triggered by the linkage is displayed as a yellow manual video recording during replay. 3) Door Access SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 58
Figure 3-61 Reset authorization e) Click the Remote Control tab to enter the remote control page and perform front and rear door remote switch control as shown in the Figure 3-62. Figure 3-62 Remote control SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 59
When you select “Select All”, all devices are configured with the same alarm level at the same time; When a low-level alarm is selected, all alarms above this level will be selected. When a device is selected, the highest level Critical is selected by default. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 60
1) Enter the server IP address or domain name at the Email server; 2) Enter the Server Port, Email user, Email password and Sender Email address in the corresponding field; 3) Click the Save button to save the current user's mail server configuration. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 61
1) According to the actual carrier, fill in the Services number and Services code, select the Query Scheduled Cycle, click Save and Query; the following dialog box appears, as shown in Figure 3-69. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 62
If you click the Add button, as shown in the Figure 3-73, the alarm linkage expression has been added, click the Save and Apply button to make it effective. Click the Delete button to delete the alarm linkage expression and click the Save and Apply button to make it effective. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 63
As shown in the Figure 3-75, you can choose to export all device MIB information or export MIB information by device type. After selecting it, click the Download to complete the MIB information export. Figure 3-75 SNMP MIB information derived 3) Asset inventory SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 64
Then return to the curve report, set the start time and the end time. If the historical data is queried, the historical curve will be generated according to the signal. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 65
Device management, Signal setting, and Batch configuration. a) Device management 1) Add/modify/delete device Click the Device Management submenu under the Device Options menu to pop up the page as shown in the Figure 3-82. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 66
Click the Save Configuration button to make the device deletion take effect. The specific operation is the same as adding a new device. Notices If you change the information about this device before clicking the Delete Device button, the device cannot be deleted. ⚫ Modify the device: SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 67
3. If a device uses this device type, the Uninstall button will be grayed out and the device type will not be uninstalled during use. b) Signal setting Click the Signal Setting submenu under the Device Options menu to pop up the page as shown in the Figure 3-85. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 68
Click the Batch Configuration submenu under the Device Options menu to pop up the page as shown in the Figure 3-88. Figure 3-88 Batch Configuration Users can perform Upload and Download operations to complete system batch configuration. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 69
Gateway, DNS addr. After modifying the network parameters, click the Save button to make the parameters take effect. Notices After modifying the IP address, the default is to jump to the new network address and log in to the intelligent monitoring system again. 2) Access Management SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 70
(4)Select the user type: "Authentication and Encryption", "Authentication, no encryption", "No authentication, no encryption"; (5)Select the authentication Protocol: "MD5", "SHA"; (6)Select the Privacy Protocol: "DES"; (7)Customize the password for the authentication algorithm and encryption algorithm. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 71
For details on how to set it up, see User Management in this section. (3)Select the Frequency of Reporting: “Monthly” and “Quarter”; SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 72
User names can only use English letters, numbers, and - and _, and the first character must be a letter or number. ⚫ Delete user (1)Select the user to be deleted in the user list; SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 73
Primary and secondary servers in turn, enter the Interval to Calibrate System Time, select the Time zone, and the Calibrating protocol, then click the Set button to make the settings take effect. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 74
Figure 3-99 Site setting As shown in the Figure 3-99, the user can modify the site information of the intelligent monitoring system, including the Site name, Site location, and Site description. g) System upgrade SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 75
The “About SmartCabinet” page displays the intelligent monitoring system Software version, Serial number, Identify code and other information, and provides a download link for the user manual, as shown in the Figure 3-102. Figure 3-102 About SmartCabinet SmartCabinet2-E Series Computer Room Solution Product User Manual...
The cold aisle high temperature alarm value defaults to 30 degrees, if the customer modifies the cold aisle alarm value, the ECO startup high temperature limit will also be changed accordingly. 2. ECO cooling mode exit condition SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 77
When a fire alarm is given, the ECO mode is immediately exited, the fan is turned off, and the ECO mode is set to prohibited. 2. When Cold Channel Temperature < Cold Channel Low Temperature Alarm Value, the system does not exit the ECO refrigeration mode and turns off the fan. SmartCabinet2-E Series Computer Room Solution Product User Manual...
A: The SmartCabinet supports the RDU-M centralized monitoring platform of Vertiv. After the network is connected, the upper RDU-M can monitor the SmartCabinet through simple settings. Multiple SmartCabinet2-E networking modes are shown in the figure 4-1. SmartCabinet2-E Series Computer Room Solution Product User Manual...
When cleaning the fins with compressed air, the direction of purging should be the direction of reverse air flow. Inspect the fins for rewinding or damage and perform SmartCabinet2-E Series Computer Room Solution Product User Manual...
Page 81
Semi-annual maintenance Suction pressure items Air exhaust pressure Suction superheat Cooling System Check the system for leaks Condenser cleaning Listen to the running sound and observe the vibration of the unit SmartCabinet2-E Series Computer Room Solution Product User Manual...
Hotline Water in the detection zone Check the computer room for leaks Belt type water sensor alarm Air conditioner condensate leak Check if the condensate pipe connection is reliable SmartCabinet2-E Series Computer Room Solution Product User Manual...
Check if the actual load has a wide range of fluctuations The fan is not operating normally Check if the fan MCB is open or not The fan cannot start Fan failure Call the Vertiv Technical Service Hotline SmartCabinet2-E Series Computer Room Solution Product User Manual...
Figure 4-2. Figure 4-2 Remove Decorative Guard of ECO Fan Module 2) Remove the (14 pcs) fixing screws of the filter hood and remove the old filter, as shown in Figure 4-3. SmartCabinet2-E Series Computer Room Solution Product User Manual...
When the life of a SmartCabinet product expires, it must be decomposed by a professional technician. The SmartCabinet products must be sent to a processing center that professionally collects and processes equipment containing hazardous materials. SmartCabinet2-E Series Computer Room Solution Product User Manual...
Need help?
Do you have a question about the SmartCabinet2-E Series and is the answer not in the manual?
Questions and answers