8. TROUBLESHOOTING

Failure of the power unit could be caused by:
• Inadequate power level (voltage / amperage) (ensure that power level complies with the power unit's electrical requirements);
• Malfunction of the motor or control module.
Simple checks can often help you find out why your power unit is inoperative. We invite you to verify the following before calling a service technician.
S
V
ituation
erification
NO POWER
Check that the power unit's electrical cord is plugged directly into a power outlet.
The power unit is equipped with a mini breaker (button on the side of the motor housing) which protects the motor against an overload. To reset the mini breaker, simply
push the button. If the power goes off one more time, call a service centre near you.
Using a screwdriver fitted with a rubber handle, touch both pins of the low voltage terminals (short circuit the 2 pins) on the side of the motor housing. If the power unit
starts, the problem lies with the low voltage wiring (installed along the piping).
You should then verify if the 24 Volts circuit is adequately connected by checking each inlet. Open the inlet cover, touch the small contacts with the head of a pair of metal
pliers with rubber handles. This will establish power and start the motor. Repeat for each vacuum inlet.
NOTE
If all vacuum inlets are functional and your flexible hose is a low voltage technology handle, then there may be a defect in the cut-
»
off switch of the hose or the hose itself�
Check the breaker on your electric circuit panel.
DECREASED
The flexible hose may be blocked. If you cannot unblock it, try inserting the opposite end of the hose into the wall inlet; touch the contacts which are located on the inside
SUCTION
of the inlet with the hose wand in order to start the power unit.
NOTE
Frame the inlet with your hands or a large enough piece of cloth (such as a towel) to ensure the maximum suction to unblock
»
the hose�
Check that the cover on the unit is well in place and that the gasket is in good condition.
Check if the disposable filtration bag needs to be replaced.
Make sure all inlets are airtight.
If the pipes are visible in certain areas: check if the fittings are well glued and that there are no air leaks.
If the pipes should be blocked behind the walls, it is possible to determine where the blockage is located by starting from the furthest inlet from the central vacuum. Insert
a tissue paper and check to see if the tissue paper reaches the dust canister. Repeat the same for each inlet.
NIVEAU
DEL
SIGNIFICATION
LEVEL
LED
Brancher le cordon
0
d'alimentation à une
prise électrique.
Le cordon d'alimentation
1
vient d' ê tre branché à une
prise électrique.
2
Système opérationnel.
Vidange/nettoyage requis.
3
Remise à zéro: Garder le
Vidange/nettoyage requis.
4
l'unité motrice reviendra au
niveau 2.
5
6
Service requis.
Constante
Clignotement Lent
Solid
Blinks Slowly
Fig. 4 LED interpretation guide
8 | DOC-532_EN REV04 | 2020�05�22

LED INTERPRETATION GUIDE

MEANING
All Husky power units with internal control module come with an explicative sticker (inside the module casing cover where
applicable).
Plug power cord to electrical
NOTE
outlet.
The indicator in step 4 does not apply to this power unit model�
»
Power cord has just
been connected to electrical
outlet.
System operational.
Cleaning/emptying required.
Reset: hold button pressed
Cleaning/emptying required.
No reset required: Power unit
will return to level 2.
Schedule service.
Service required.
Clignotement Rapide
Blinks Fast
ORIGINAL INSTRUCTIONS