EGG STATION (ES-600 & ES-1200) OWNER INFORMATION (continued) Service/Technical Assistance Refer to the service agency directory and fill in the information below: If you experience any problems with the installation or operation of your unit, contact your local Roundup Authorized Service Agency Authorized Service Agency.
Page 4
EGG STATION (ES-600 & ES-1200) IMPORTANT SAFETY INFORMATION (continued) In addition to the warnings and cautions in this manual, • WARNING ELECTRICAL SHOCK HAZARD. use the following guidelines for safe operation of the FAILURE TO FOLLOW THESE INSTRUCTIONS unit. COULD RESULT IN SERIOUS INJURY OR DEATH.
EGG STATION (ES-600 & ES-1200) SPECIFICATIONS Electrical Ratings Model Designation Model Mfg. Volts Watts Amp Hertz Number Number ES-600XX or ES-600CV 9300530 2900 12.6 50/60 ES-604XX or ES-1200XX ES-604CV 9300574 2900 12.6 50/60 ES-1200CV 9300532 2900 12.6 50/60 TYPE OF POWER CORD C = COMMERCIAL WARNING ELECTRICAL SHOCK HAZARD.
EGG STATION (ES-600 & ES-1200) INSTALLATION Unpacking CAUTION 1. Remove unit and all packing materials from ship- All electrical service connections must be in ping carton. accordance with local electrical codes and any other applicable codes. NOTE: If any parts are missing or damaged, con- tact Antunes Technical Service IMMEDIATELY at WARNING 1-877-392-7854 (Toll free in the U.S.
EGG STATION (ES-600 & ES-1200) OPERATION 3. Break the egg yolks if desired. Preparing Unit 4. Close the cover. 1. Turn the Rocker Switch (power On/Off) to ON (Figure 1). 5. Fill the trough (Figure 2) on top of the cover with water, using the plastic dispensing bottle provided.
EGG STATION (ES-600 & ES-1200) OPERATION (continued) To disable the Bacon Timer, press the Time 1 and Time 12. Raise the Egg Rack completely off the eggs and 2 buttons simultaneously for 3 or more seconds. The use a spatula to remove the eggs. blue Bacon LED will turn off.
EGG STATION (ES-600 & ES-1200) MAINTENANCE (continued) Checking Grill Platen Temperature Checking Cycle Times (Monthly) NOTE: A pyrometer is required for this procedure. CAUTION: Grill surfaces will be hot. Care should be taken when operating this piece of equipment. WARNING NOTE: A stopwatch is required for this procedure.
EGG STATION (ES-600 & ES-1200) TROUBLESHOOTING WARNING To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip- ment should be performed by qualified service personnel. The unit should be unplugged when servicing. Problem Possible Cause Corrective Action Unit fails to operate and...
EGG STATION (ES-600 & ES-1200) TROUBLESHOOTING (continued) Control Board LEDs STATUS Solid State The control Board has three on board LEDs (Figure Green Relay 5) to determine the status of the unit and to assist in YELL Bauart gapruit Yellow PRODUCT SERVICE troubleshooting.
LIMITED WARRANTY Equipment manufactured by Roundup Food Equipment Division of A.J. Antunes & Co. has been constructed of the finest materials available and manufactured to high quality standards. These units are warranted to be free from mechanical and electrical defects for a period of one year from date of purchase or 18 months from shipment from factory, whichever occurs first, under normal use and service, and when installed in accordance with manufacturer’s recommendations.
Need help?
Do you have a question about the roundup ES-600 and is the answer not in the manual?
Questions and answers