FEI Baseline 12-0247 Instruction Manual

FEI Baseline 12-0247 Instruction Manual

Hydraulic hand dynamometer with digital lcd gauge

Advertisement

Quick Links

Instruction Manual
Hydraulic Hand Dynamometer
with Digital LCD Gauge
FABRICATION
ENTERPRISES INC.
Manufacturer and Master
Distributor of Physical Therapy
12-0247
REF
and Rehabilitation Products
ver 0220

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Baseline 12-0247 and is the answer not in the manual?

Questions and answers

Summary of Contents for FEI Baseline 12-0247

  • Page 1 Instruction Manual Hydraulic Hand Dynamometer with Digital LCD Gauge FABRICATION ENTERPRISES INC. Manufacturer and Master Distributor of Physical Therapy 12-0247 and Rehabilitation Products ver 0220...
  • Page 2 Parts/Specifications MENU Button ON/ENTER Button 5 Level Adjustment Handle Clamp Specifications 300 lb / 136 kg capacity Grip adjust range 1.35 in / 3.35 cm Weight 22.6 oz / 638 gm...
  • Page 3 Hydraulic Hand Dynamometer with Digital LCD Gauge Purpose / Intended Use The purpose of this Medical Device is to measure a patient’s grip strength. It can be used to evaluate initial and ongoing impacts of hand trauma and dysfunction. The Baseline Hydraulic Hand Dynamometer can be used to measure isometric force and peak strength with five adjustable grip positions.
  • Page 4 Instructions How to turn on/off unit: Button Press Pre s s O N / E N T E R t o Screen s w i t c h O N a n d O F F. ENTER How to zero out unit: Display “_ _ _ _ ”...
  • Page 5 Norms for Adult Grip Strength A recent study by Dr. Virgil Mathiowetz indicates that “... individuals using the Baseline® dynamometer are justified in using the normative data collected with the Jamar® dynamometer... ” For each test of grip strength, the subject was seated with shoulder adducted and neutrally rotated with the elbow between 0˚...
  • Page 6 Grip Strength (Dominant Hand) Women 121.0 121.8 120.8 119.7 116.8 113.6 109.9 104.3 101.1 91.1 89.7 78.7 75.3 74.5 74.1 70.4 70.4 65.7 65.8 62.8 62.2 57.3 55.1 49.6 49.6 42.6 20-24 25-29 30-34 35-39 40-44 45-49 50-54 55-59 60-64 65-69 70-74 All Ages...
  • Page 8 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (USA) Authorized CE representative: tel: +1-914-345-9300 • 800-431-2830 AJW Technology Consulting GmbH fax: +1-914-345-9800 • 800-634-5370 Königsallee 106 FabEnt.com 40215 Düsseldorf (Germany) ©2021 FEI, all rights reserved. Baseline is a registered trademark of Goldberg.

Table of Contents