CALIBRATION PROCEDURE:
• Charge unit over night before calibrating.
• Install mechanical steering wheel fixture (with inclinometer permanently mounted onto it)
onto a calibration stand that can be adjusted for 0 degrees and some other known value
such as 5 or 10 degrees.
• Set the cal. stand to 0 degrees and adjust the ZERO control on the front panel of the
inclinometer for 00.0 degrees.
• Set the cal. stand to eg. 10 degrees and adjust the GAIN control on the front panel of the
inclinometer for 10.0 degrees.
• Repeat the following two procedures until the values are stable.