Sinclair CFO-20P User Manual page 21

Table of Contents

Advertisement

Malfunction
No.
Name
Freon-lacking
4
protection
Overload
5
protection
Overcurrent
6
protection
Model
Rated oltage
Rated frequency
Power input
Dehumidifying (temper. 30°C a RH 80%)
Operating temperature
Refrigerant (charge)
Sound pressure level
Weight netto / bruto
Water tank volume
Display
Code
Unit's
Condition
Display
Window
The compressor
stops.
F0
Buttons are
invalid.
The
H3
compressor
stops and
fan motor
keeps on
running.
Buttons are
E5
invalid.
18
Possible Causes
● Refrigerant is leaking.
● System is blocked
● Ambient operation condition is
bad.
● The evaporator and condenser
are blocked with filth.
● The system is abnormal.
● Relay is short-circuited or
broken-circuited;
● Operation environment
condition is formidable high
temperature and high humidity.
CFO-20P
220–240 V~
360 W (max. 450 W)
20 l / day
R290 (0,11kg)
max. 43 dB(A)
15,5 / 17,0 kg
3,5 l
CFO-40P
50 Hz
670 W (max. 900 W)
40 l / day
5 - 32 °C
R290 (0,15kg)
max. 48 dB(A)
22,5 / 24,5 kg
6,5 l

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfo-40p

Table of Contents