Product Description
DU0/5 and DU0/25 Differential Pressure Sensors
Application
Differential pressure sensors with power output DC 0 V to 10 V for
measuring the pressure or differential pressure in ventilation and air
conditioning systems.
The sensors convert the measured pressure/differential pressure into
a proportional voltage signal between DC 0 V and 10 V.
The voltage signal can be used directly for closed-loop control and/or
display.
DU0/5 has three adjustable pressure ranges: 0 mbar to 1 mbar,
0 mbar to 3 mbar or 0 mbar to 5 mbar.
DU0/25 has three adjustable pressure ranges: 0 mbar to 10 mbar,
0 mbar to 16 mbar or 0 mbar to 25 mbar.
Content
Important Information Regarding Product Safety ..................................................................................................2
Item........................................................................................................................................................................3
Technical Data.....................................................................................................................................................3
Dimensions ..........................................................................................................................................................3
Connection...........................................................................................................................................................4
Installation..............................................................................................................................................................4
Commissioning ......................................................................................................................................................6
Änderungen vorbehalten - Contents subject to change - Sous réserve de modifications - Reservado el derecho a modificación - Wijzigingen
voorbehouden - Con riserva di modifiche - Innehåll som skall ändras - Změny vyhrazeny - Zmiany zastrzeżone - Возможны изменения -
A változtatások jogát fenntartjuk - 保留未经通知而改动的权力
Kieback&Peter GmbH & Co. KG
Tempelhofer Weg 50, 12347 Berlin/Germany
Telefon: +49 30 60095-0, Telefax: +49 30 60095-164
www.kieback-peter.de, info@kieback-peter.com
Datasheet 1.50-22.025-01-EN
DU0/5, DU0/25
Page
A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DU0/5 and is the answer not in the manual?

Questions and answers

Summary of Contents for Kieback&Peter DU0/5

  • Page 1 The voltage signal can be used directly for closed-loop control and/or display. ■ DU0/5 has three adjustable pressure ranges: 0 mbar to 1 mbar, 0 mbar to 3 mbar or 0 mbar to 5 mbar. ■ DU0/25 has three adjustable pressure ranges: 0 mbar to 10 mbar, 0 mbar to 16 mbar or 0 mbar to 25 mbar.
  • Page 2 Important Information Regarding Product Safety Safety Instructions This data sheet contains information on installing and commissioning the product "DU0/5, DU0/25". Each person who carries out work on this product must have read and understood this data sheet. If you have any questions that are not resolved by this data sheet, you can obtain further information from the supplier or manufacturer.
  • Page 3 Issue 2010-07-22 Datasheet 1.50-22.025-01-EN Product Description DU0/5, DU0/25 Item DU0/5 Differential pressure sensor, 3 adjustable measuring ranges DU0/25 Differential pressure sensor, 3 adjustable measuring ranges Technical Data Nominal voltage DC 13.5 V to 33.0 V; AC 24 V ± 15% Power consumption <10 mA...
  • Page 4 Datasheet 1.50-22.025-01-EN Issue 2010-07-22 DU0/5, DU0/25 Product Description Connection 0 V AC/DC 0..10 V DC 24 V AC/DC Installation The installation position is to be selected so that the permitted conditions for the differential pressure sensor are maintained (see Section Technical Data).
  • Page 5 Issue 2010-07-22 Datasheet 1.50-22.025-01-EN Product Description DU0/5, DU0/25 A connection set is provided for connecting the differential pressure sensor. ► Drill a hole for the ventilation duct Ø 16 mm. ► Insert a rubber grommet. ► Push the connection nozzle into the grommet.
  • Page 6 Datasheet 1.50-22.025-01-EN Issue 2010-07-22 DU0/5, DU0/25 Product Description Commissioning (1) LED (2) Zero point reset button (3) DIP switch (4) Pressure connection at P2 (lower pressure/ bigger vacuum) (5) Pressure connection at P2 (higher pressure/ smaller vacuum) Adjusting the measuring range...

This manual is also suitable for:

Du0/25

Table of Contents