Do you have a question about the CF-Eco and is the answer not in the manual?
Questions and answers
Summary of Contents for Dynamic Engineering CF-Eco
Page 1
Not e ! Bef or e in st al la t ion an d u s e in ap pl ic ati on f ol low these i nst r uct ion s Distributed by: Dynamic Engineering Australia Ph: +618 9356 7633 7/52 Kent Street Cannington WA 6107 Email: sales@dynamiceng.com.au...
Page 2
Field of Operation. The CF-ECO unit are dust collectors for collecting dust, welding smoke and other dry pollutants. The unique baffling system works as spark trap and directs heavier particles directly down towards the bottom of the unit. Small particles are filtered through the cartridge filter.
Page 3
3. Open the valve on the unit 3 times 10 seconds. 30 seconds pause between each 10 sec. 4. CF-Eco, open the door and take out the dust tray and dispose of material in accordance with local regulations. Put the dust tray in again and close the door.
Page 4
Replacement of Jet-Pulse Actuator Mechanism. The 7” (175mm) Jet-Pulse that is part of the cleaning mechanism inside the filter cartridge will eventually wear reducing cleaning performance. Check for signs of excessive wear when doing normal filter service or if a decrease in filter cleaning effectiveness is observed.
Page 5
500mm 595mm Ø 200mm 850mm 455mm 895mm (mit Motor) Distributed by: Dynamic Engineering Australia Ph: +618 9356 7633 7/52 Kent Street Cannington WA 6107 Email: sales@dynamiceng.com.au www.dynamiceng.com.au...