Video intercom two-wire kit

Advertisement

DS-KH6320Y-WTE2
Video Intercom Two-Wire Indoor Station
Diagram References
Appearance
1
1
Display Screen
2
Microphone
3
Debugging Port
4
Two-Wire Interface
5
Loudspeaker
6
TF Card Slot
7
Alarm Terminal
Note: The debugging port is used for debugging only.
2
Wiring
There are 20 pins in the terminal on the rear panel of the indoor station: 2 RS-485 pins, 5 reserved pins, 4
relay output pins, 8 alarm input pins, and 1 GND pin.
Wire the devices with power supply cables.
Caution: Make sure all the related equipment is power-off during the installation.
Note: The power output of the indoor station is 24 VDC, 4 W.
Installation
3
The wall mounting plate and the junction box are required to install the indoor station onto the wall.
The dimension of junction box should be 75 mm (width) × 75 mm (length) × 50 mm (depth).
The dimension of wall mounting plate is shown.
Before you begin:
1. Tools that you need to prepare for installation: Make sure the device in the package is in good condition
and all the assembly parts are included.
2. The power supply the indoor station supports is 24 VDC. Please make sure your power supply matches
your indoor station.
3. Make sure all the related equipment is power-off during the installation.
4. Check the product specification for the installation environment.
Wall Mounting with Junction Box
1. Chisel a hole in the wall. The size of the hole should be 76 mm (width) × 76 mm (length) × 50 mm (depth).
2. Insert the junction box to the hole chiseled on the wall.
3. Fix the wall mounting plate to the junction box with 2 screws.
4. Hook the indoor station to the wall mounting plate tightly by inserting the plate hooks into the slots on the
rear panel of the indoor station, during which the lock catch will be locked automatically.
4
Getting Started
Activate Indoor Station
1
You are required to activate the device first by setting a strong password for it before
you can use the device.
1. Power on the device. It will enter the activation page automatically.
2. Create a password and confirm it.
3. Tap OK to activate the indoor station.
2
Quick Configuration
• After Activation, you can follow the wizard to complete quick configuration, including language
settings, network settings, indoor station settings, linked devices settings, etc.
• If you want to enter the wizard page, you can tap Settings →
→ Configuration, and enter the
admin (activation) password. Tap
to enter the system maintenance page.
Refer to Video Intercom Indoor Station Configuration Guide (scan the QR code) for details.
Refer to Video Intercom Indoor Station Operation Guide (scan the QR code) for details.
DS-KAD704Y
E N G L I S H
Video Intercom Two-Wire Video/Audio Distributor
Diagram References
Appearance
1
1
Power Indicator
2
Cascade Interface
3
Terminals
4
LAN
5
6
Network Indicator
7
Power Input
8
Reset
Cascade Network Indicator
2
Wiring
Wire the devices with power supply cables.
Door station should be connected to CH4 of the video/audio distributor with two-wire cables.
Indoor Station should be connected to any terminal of CH1 to CH3 of the video/audio distributor with two-
wire cables.
Caution: Make sure all the related equipment is power-off during the installation.
Note: The power output of CH1 to CH3: 12 VDC, Max. 4W. The power output of CH4: 24 VDC, Max. 8W.
Installation
3
Before you begin:
Make sure the device in the package is in good condition.
Make sure all the related equipment is power-off during the installation.
Check the product specification for the installation environment.
1. Fix the DIN rail onto the wall.
Note: You are required to utilize a matched DIN rail.
2. Press the red clip upward, and lock it to the DIN rail.
1
3
1
\
2
3
MAX
MAX
4W
8W
IN
OUT
24VDC
1
IN
OUT
4
5
6
7
2
3
MAX
MAX
4W
8W
24VDC
8
2
Indoor Station
Door Station
MAX
MAX
4W
8W
IN
OUT
24VDC
IN
OUT
Video/Audio Distributor
24 VDC
Power Input
Network
Network
Note:
The power adapter is contained only in the
DS-KIS702Y-P
Kit.
The detail for the power adapter contained in the package is as follows:
Model
Manufacturer
KPL-060M-II
Channel Well Technology Co., Ltd
MAX
MAX
4W
8W
24VDC

Advertisement